There is concern that the levels of inertia in power systems may decrease in the future, due to increased levels of energy being provided from renewable sources, which typically have little or no inertia. Voltage source converters (VSC) used in high voltage direct current (HVDC) transmission applications are often deliberately controlled in order to de-couple transients to prevent propagation of instability between interconnected systems. However, this can deny much needed support during transients that would otherwise be available from system inertia provided by rotating plant.

27 February 2014 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
FCF. Coffele
F. Coffele
CBCampbell Booth
Campbell Booth
ADAdam Dysko
Adam Dysko
Distribution networks are evolving toward the vision of smart grids, with increasing penetration of distributed generation (DG), introduction of active network management (ANM), and potentially islanded modes of operation. These changes affect fault levels and fault current paths and have been demonstrated to compromise the correct operation of the overcurrent protection system. This paper presents an adaptive overcurrent protection system which automatically amends the protection settings of all overcurrent relays in response to the impact of DG, ANM, and islanding operation. The scheme has been developed using commercially available protection devices, employs IEC61850-based communications, and has been demonstrated and tested using a hardware-in-the-loop laboratory facility. A systematic comparison of the performance of the proposed adaptive scheme alongside that of a conventional overcurrent scheme is presented. This comparison quantifies the decrease in false operations and the reduction of mean operating time that the adaptive system offers.

28 March 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Sohrab MirsaeidiSohrab Mirsaeidi
Sohrab Mirsaeidi
XDXinzhou Dong
Xinzhou Dong
DTDimitrios Tzelepis
Dimitrios Tzelepis
DSDalila Mat Said
Dalila Mat Said
ADAdam Dysko
Adam Dysko
CBCampbell Booth
Campbell Booth
High-Voltage Direct Current (HVDC) systems are being widely employed in various applications because of their numerous advantages such as bulk power transmission, efficient long-distance transmission, and flexible power-flow control. However, Line-Commutated Converter (LCC) based HVDC systems suffer from commutation failure which is a major drawback, leading to increased device stress and interruptions in transmitted power. This paper proposes a predictive control strategy, deploying a Commutation Failure Prevention Module (CFPM) to mitigate the commutation failures during AC system faults. The salient feature of the proposed strategy is that it has the ability to temporarily decrease the firing angle of thyristor valves depending on the fault intensity to ensure a sufficient commutation margin. In order to validate the performance of the proposed strategy several simulations have been conducted on CIGRE Benchmark HVDC model using PSCAD/EMTDC software. Additionally, practical performance and feasibility of the proposed strategy is evaluated through laboratory testing, using the real time Opal-RT hardware prototyping platform. Simulation and experimental results demonstrate that the proposed strategy can effectively inhibit the commutation failure or repetitive commutation failures under different fault types, fault impedances and fault initiation times.

7 December 2015 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
XCXue Cao
Xue Cao
BSBruce Stephen
Bruce Stephen
IAIbrahim F. Abdulhadi
Ibrahim F. Abdulhadi
CBCampbell Booth
Campbell Booth
GBGraeme M. Burt
Graeme M. Burt
Future power systems could benefit considerably from having a continuous real-time estimate of system inertia. If realized, this could provide reference inputs to proactive control and protection systems which could enhance not only system stability but also operational economics through, for example, more informed ancillary reserve planning using knowledge of prevailing system conditions and stability margins. Performing these predictions in real time is a significant challenge owing to the complex stochastic and temporal relationships between available measurements. This paper proposes a statistical model capable of estimating system inertia in real time through observed steady-state and relatively small frequency variations; it is trained to learn the features that inter-relate steady-state averaged frequency variations and system inertia, using historical system data demonstrated over two consecutive years. The proposed algorithm is formulated as a Gaussian Mixture Model with temporal dependence encoded as Markov chains. Applied to the U.K. power system, it produces an optimized mean squared error within 0.1 s2 for 95% of the daily estimation if being calibrated on a half-hourly basis and maintains robustness through measurement interruptions of up to a period of two hours.

1 September 2020 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
SZSuyang Zhou
Suyang Zhou
ZHZijian Hu
Zijian Hu
WGWei Gu
Wei Gu
MJMeng Jiang
Meng Jiang
MCMeng Chen
Meng Chen
CBCampbell Booth
Campbell Booth

14 August 2018 in Inventions
Verified
Journal Article
Open access
PDF file
ARAnastasios Oulis Rousis
Anastasios Oulis Rousis
DTDimitrios Tzelepis
Dimitrios Tzelepis
IKIoannis Konstantelos
Ioannis Konstantelos
CBCampbell Booth
Campbell Booth
GSGoran Strbac
Goran Strbac
This paper is concerned with the design of an autonomous hybrid alternating current/direct current (AC/DC) microgrid for a community system, located on an island without the possibility of grid connection. It is comprised of photovoltaic (PV) arrays and a diesel generator, AC loads, and battery energy storage devices for ensuring uninterruptible power supply during prolonged periods of low sunshine. A multi-objective, non-derivative optimisation is considered in this residential application; the primary objective is the system cost minimisation, while it is also required that no load shedding is allowed. Additionally, the CO2 emissions are calculated to demonstrate the environmental benefit the proposed system offers. The commercial software, HOMER Pro, is utilised to identify the least-cost design among hundreds of options and simultaneously satisfy the secondary objective. A sensitivity analysis is also performed to evaluate design robustness against the uncertainty pertaining to fuel prices and PV generation. Finally, an assessment of the capabilities of the utilised optimisation platform is conducted, and a theoretical discussion sheds some light on the proposal for an enhanced design tool addressing the identified issues.