Christopher Thurber

Christopher Thurber

Auto-generated profile, based on publicly available information

Christopher Thurber

Materials Science, 1702 Building, The Dow Chemical Company, Midland, Michigan 48667, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2017 in Science
Verified
Journal Article
Closed access
PDF file
JEJames M. Eagan
James M. Eagan
JXJun Xu
Jun Xu
RGRocco DI GIROLAMO
Rocco DI GIROLAMO
CTChristopher M. Thurber
Christopher M. Thurber
CMChristopher W Macosko
Christopher W Macosko
GCGeoffrey W. Coates
Geoffrey W. Coates
How to make opposites compatible: Polyethylene (PE) and isotactic polypropylene ( i PP) are the two most widely used commodity plastics and thus make up a large fraction of the waste stream. However, the two plastics will not mix together, which limits options for dealing with mixed waste and decreases the value of recycled products. Eagan et al. report the synthesis of multiblock copolymers of i PP and PE by using a selective polymer initiator (see the Perspective by Creton). The high-molecular-weig ht blocks could be used to reinforce the interface between i PP and PE and allow blending of the two polymers. Science , this issue p. 814 ; see also p. 797

22 February 2017 in Polymer Engineering & Science
Verified
Journal Article
Closed access
PDF file
CTChristopher Thurber
Christopher Thurber
LGLiangliang Gu
Liangliang Gu
JMJason C. Myers
Jason C. Myers
TLTimothy P. Lodge
Timothy P. Lodge
CMChristopher W. Macosko
Christopher W. Macosko

13 March 2025 in Applied Spectroscopy
Verified
Journal Article
Closed access
XCXiaoyun Chen
Xiaoyun Chen
JWJin Wang
Jin Wang
CTChristopher Thurber
Christopher Thurber
MBMatthew Benedict
Matthew Benedict
KOKurt Olson
Kurt Olson
MBMichael Bishop
Michael Bishop
A new method based on near-infrared (NIR) hyperspectral imaging (HSI) has been developed for online polymer film thickness mapping. Traditional online methods, including X-ray, capacitance, and physical gauging (micrometers), can only determine film thickness for a point with each measurement. The NIR-HIS method allows the determination of film thickness for a line based on each image, thus enabling true real-time two-dimensional (2D) mapping of film thickness as the film translates in front of the instrument. A Specim NIR camera, 1000–2500 nm, 384 (spatial) × 288 (spatial) pixels, was used in this study for various low-density polyethylene (LDPE), and high-density polyethylene (HDPE) films. Sample thickness between μm to mm can be mapped based on the myriad NIR absorbance bands with various molar absorptivity. The 2310 nm NIR peak was found to be the most effective feature for determining film thickness over the range of polyethylene film studied in this project: 10∼100 μm. A good correlation was found between the 2310 nm absorbance and the incumbent X-ray thickness scanner results. Interference fringes were found to be a potential source of error for quantitative analysis of thin films, and a classical least squares (CLS) analysis was found to be effective in removing fringes. This method was implemented to map out film thickness in real-time in an industrial blown film process.