Maria Inês Rocha Miritello Santoro

Maria Inês Rocha Miritello Santoro

Auto-generated profile, based on publicly available information

Maria Inês Rocha Miritello Santoro

University of São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MSMaria Inês R.M. Santoro
Maria Inês R.M. Santoro
NKNajla Mohamad Kassab
Najla Mohamad Kassab
ASAnil K. Singh
Anil K. Singh
EKErika R.M. Kedor-Hackmam
Erika R.M. Kedor-Hackmam

31 July 2009 in Analytical Letters
Verified
Journal Article
Closed access
FGFábio Pereira Gomes
Fábio Pereira Gomes
PGPedro López García
Pedro López García
JAJoão Marcel Porto Alves
João Marcel Porto Alves
ASAnil Kumar Singh
Anil Kumar Singh
EKErika Rosa Maria Kedor-Hackmann
Erika Rosa Maria Kedor-Hackmann
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
High-performance liquid-chromatographic (HPLC) methods were validated for determination of pravastatin sodium (PS), fluvastatin sodium (FVS), atorvastatin calcium (ATC), and rosuvastatin calcium (RC) in pharmaceuticals. Two stability-indicating HPLC methods were developed with a small change (10%) in the composition of the organic modifier in the mobile phase. The HPLC method for each statin was validated using isocratic elution. An RP-18 column was used with mobile phases consisting of methanol–water (60:40, v/v, for PS and RC and 70:30, v/v, for FVS and ATC). The pH of each mobile phase was adjusted to 3.0 with orthophosphoric acid, and the flow rate was 1.0 mL/min. Calibration plots showed correlation coefficients (r) > 0.999, which were calculated by the least square method. The detection limit (DL) and quantitation limit (QL) were 1.22 and 3.08 µg/mL for PS, 2.02 and 6.12 µg/mL for FVS, 0.44 and 1.34 µg/mL for ATC, and 1.55 and 4.70 µg/mL for RC. Intraday and interday relative standard deviations (RSDs) were <2.0%. The methods were applied successfully for quantitative determination of statins in pharmaceuticals.

1 December 2005 in Revista Brasileira de Ciências Farmacêuticas
Verified
Journal Article
Open access
PDF file
NKNajla Mohamad Kassab
Najla Mohamad Kassab
ASAnil Kumar Singh
Anil Kumar Singh
EKErika Rosa Maria Kedor-Hackmam
Erika Rosa Maria Kedor-Hackmam
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
The objective of this research was to develop and validate an analytical method for quantitative determination of ciprofloxacin (CIP) and norfloxacin (NOR) in pharmaceutical preparations. A simple and rapid chromatographic method was developed and validated for quantitative determination of two fluoroquinolone antibiotics in tablets and injection preparations. The quinolones were analyzed by using a LiChrospher® 100 RP-18 column (5 µm, 125 x 4 mm) and a mobile phase consisted of water:acetonitrile:triethylamine (80:20:0.3 v/v/v). The pH of final mixture was adjusted to 3.3 with phosphoric acid. The flow rate was 1.0 mL/min and UV detection was made at 279 nm. The analyses were performed at room temperature (24 ± 2 ºC). CIP and NOR were eluted within 5 min. The calibration curves were linear (r > 0.9999) over a concentration range from 4.0 to 24.0 µg/mL. The relative standard deviation (RSD) was < 1.0% and the mean recovery was 101.85%. O objetivo desta pesquisa foi desenvolver e validar um método analítico para a determinação quantitativa do ciprofloxacino (CIP) e do norfloxacino (NOR) em preparações farmacêuticas. Um método cromatográfico simples e rápido foi desenvolvido e validado para a determinação quantitativa de dois antibióticos fluoroquinolônicos em comprimidos e injetáveis. As quinolonas foram analisadas empregando-se uma coluna RP-18, LiChrospher® 100 (125 x 4 mm, 5µm) e fase móvel constituída por água:acetonitrila:trietilamina (80:20:0.3 v/v/v). O pH da mistura final foi ajustado a 3,3 com ácido fosfórico. A vazão da fase móvel foi de 1,0 mL/min e a detecção em UV a 279 nm. As análises foram realizadas à temperatura ambiente (24±2 ºC). O CIP e o NOR eluíram em menos de 5 min. As curvas de calibração foram lineares (r > 0.9999) na faixa de concentração entre 4,0 e 24,0 µg/mL. O desvio padrão relativo (RSD) foi < 1,0% e a recuperação média foi de 101,85%

1 November 2001 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Open access
PDF file
ASAnil K Singh
Anil K Singh
EKErika R M Kedor-Hackmann
Erika R M Kedor-Hackmann
MSMaria Inês R M Santoro
Maria Inês R M Santoro
Atenolol (AT) and metoprolol (MT) are predominantly used in the treatment of angina pectoris, certain arrhythmias, systemic hypertension, and several other cardiovascular disorders. Both compounds are produced commercially in the racemic form, although the S-form is responsible for the desired biological effect. This paper describes a simple, rapid, precise, and accurate method for separating the enantiomers of AT and MT. AT isomers are separated by using a Chiralcel OD® column (250 × 4.6 mm, 10 μm), hexane–ethanol–diethylamine–acetic acid (60 + 40 + 0.2 + 0.2, v/v/v/v) as the mobile phase, and a flow rate of 1.0 mL/min. MT isomers are separated by using a mobile phase with the same components in the following proportions (40 + 60 + 0.2 + 0.2, v/v/v/v) and a flow rate of 0.8 mL/min. Ultraviolet detection was at 276 nm for both analytes. The coefficients of variation (CVs) and average recoveries (ARs) for the R-enantiomers in samples A, B, C, D, and E were 1.15 and 101.06%, 0.74 and 99.25%, 1.05 and 102.57%, 0.84 and 101.57%, and 0.86 and 98.62%, respectively. The CVs and ARs for the S-enantiomers in samples A, B, C, D, and E were 1.33 and 98.87%, 0.99 and 100.76%, 1.17 and 101.69%, 1.26 and 100.39%, and 1.40 and 99.39%, respectively. The standard curves of R-AT, S-AT, R-MT, and S-MT showed good linearity over the concentration range studied with correlation coefficients of 0.9991, 0.998, 0.9988, and 0.999, respectively.

1 September 2013 in Brazilian Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
PDF file
VSViviane Benevenuti Silva
Viviane Benevenuti Silva
AGAngel Arturo Gaona Galdos
Angel Arturo Gaona Galdos
CMCintia Maria Alves Mothe
Cintia Maria Alves Mothe
MPMichele Bacchi Pallastrelli
Michele Bacchi Pallastrelli
MPMaria Segunda Aurora Prado
Maria Segunda Aurora Prado
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm) with acetonitrile:water 50:50 (v/v) as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.

1 November 2009 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Open access
PDF file
RSRenata Soares
Renata Soares
ASAnil Kumar Singh
Anil Kumar Singh
EKErika Rosa Maria Kedor-Hackmann
Erika Rosa Maria Kedor-Hackmann
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
Many therapeutic agents are commercialized under their racemic form. The enantiomers can show differences in the pharmacokinetic and pharmacodynamic profile. The use of a pure enantiomer in pharmaceutical formulations may result in a better therapeutic index and fewer adverse effects. Atropine, an alkaloid of Atropa belladonna, is a racemic mixture of l-hyoscyamine and d-hyoscyamine. It is widely used to dilate the pupil. To quantify these enantiomers in ophthalmic solutions, an HPLC method was developed and validated using a Chiral AGP column at 20C. The mobile phase consisted of a buffered phosphate solution (containing 10 mM 1-octanesulfonic acid sodium salt and 7.5 mM triethylamine, adjusted to pH 7.0 with orthophosphoric acid) and acetonitrile (99 + 1, v/v). The flow rate was 0.6 mL/min, with UV detection at 205 nm. In the concentration range of 14.026.0 g/mL, the method was found to be linear (r > 0.9999), accurate (with recovery of 100.1100.5), and precise (RSD system 0.6; RSD intraday 1.1; RSD interday 0.9). The method was specific, and the standard and sample solutions were stable for up to 72 h. The factorial design assures robustness with a variation of 10 in the mobile phase components and 2C of column temperature. The complete validation, including stress testing and factorial design, was studied and is presented in this research.