Erika Rosa Maria Kedor-Hackmann

Erika Rosa Maria Kedor-Hackmann

Auto-generated profile, based on publicly available information

Erika Rosa Maria Kedor-Hackmann

Department of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP 05508-000, Brazil

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2004 in Revista Brasileira de Ciências Farmacêuticas
Verified
Journal Article
Open access
PDF file
EDElizângela Abreu Dutra
Elizângela Abreu Dutra
DODaniella Almança Gonçalves da Costa e Oliveira
Daniella Almança Gonçalves da Costa e Oliveira
EKErika Rosa Maria Kedor-Hackmann
Erika Rosa Maria Kedor-Hackmann
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
The aim of this research was to determine the sun protection factor (SPF) of sunscreens emulsions containing chemical and physical sunscreens by ultraviolet spectrophotometry. Ten different commercially available samples of sunscreen emulsions of various manufactures were evaluated. The SPF labeled values were in the range of 8 to 30. The SPF values of the 30% of the analyzed samples are in close agreement with the labeled SPF, 30% presented SPF values above the labeled amount and 40% presented SPF values under the labeled amount. The proposed spectrophotometric method is simple and rapid for the in vitro determination of SPF values of sunscreens emulsions. O objetivo desta pesquisa foi determinar o Fator de Proteção Solar (FPS) de emulsões contendo filtros solares físicos e químicos por espectrofotometria no ultravioleta. Foram analisadas dez amostras comerciais de emulsões de diferentes fabricantes. Os valores de FPS rotulados foram na faixa de 8 a 30. Das emulsões analisadas, 30% apresentaram valores de FPS próximos do valor rotulado, 30% apresentaram valores acima e 40% apresentaram valores abaixo do valor rotulado. O método espectrofotométrico proposto é simples e rápido para determinação preliminar in vitro do FPS de emulsões protetoras solar

22 May 2006 in International Journal of Cosmetic Science
Verified
Journal Article
Closed access
PDF file
EKE. R. M. Kedor‐Hackmann
E. R. M. Kedor‐Hackmann
MGM. L. De Lourdes Pérez González
M. L. De Lourdes Pérez González
ASA. K. Singh
A. K. Singh
MSM. I. R. M. Santoro
M. I. R. M. Santoro

30 May 2008 in Journal of Chromatography A
Verified
Journal Article
Closed access
AGAngel Arturo Gaona-Galdos
Angel Arturo Gaona-Galdos
LFLuiz Antonio Zanolli Filho
Luiz Antonio Zanolli Filho
MTMarina Franco Maggi Tavares
Marina Franco Maggi Tavares
MPMaría Segunda Aurora Prado
María Segunda Aurora Prado
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
ÉKÉrika Rosa Maria Kedor-Hackmann
Érika Rosa Maria Kedor-Hackmann

1 March 2006 in Revista Brasileira de Ciências Farmacêuticas
Verified
Journal Article
Open access
PDF file
EKErika Rosa Maria Kedor-Hackmann
Erika Rosa Maria Kedor-Hackmann
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
ASAnil Kumar Singh
Anil Kumar Singh
APAndréia Cricco Peraro
Andréia Cricco Peraro
First-derivative ultraviolet spectrophotometric (Method I) and reversed phase high performance liquid chromatographic (Method II) methods were developed. The validated methods were applied for quantitative determination of ketoconazole in commercial and simulated emulsion formulations. Quantitative first-derivative UV spectrophotometric determinations were made using the zero-crossing method at 257 nm, with methanol as background solvent. Liquid chromatographic analysis was carried out on a LiChrospher® 100 RP-18 (5µm) column. A mixture of triethylamine in methanol (1:500 v/v) and 0.5% ammonium acetate solution (75:25 v/v) was used as mobile phase at a flow rate of 1.0 mL/min with UV detection at 225 nm. The retention time of ketoconazole and terconazole were 3.9 min and 5.9 min, respectively, the later being used as internal standard. Analytical curves were linear within a concentration range from 5.0 to 30.0 µg/mL for Method I and 20.0 to 80.0 µg/mL for Method II, with correlation coefficients of 0.9997 and 0.9981, respectively. The relative standard deviation (RSD) was 0.56% and 0.41% for simulated and commercial emulsion formulations, respectively, using Method I. The corresponding values were 2.13% and 1.25%, respectively, using Method II. The percentage recoveries were above 100% for both methods. The excipients did not interfere in the analysis. The results showed that either method can be used for rapid ketoconazole determination in pharmaceutical emulsions with precision, accuracy and specificity. Foram desenvolvidos e padronizados métodos por espectrofotometria no ultravioleta (UV) por derivada de primeira ordem (Método I) e cromatografia líquida de alta eficiência (CLAE) (Método II) para a determinação quantitativa de cetoconazol em formulações farmacêuticas sob a forma de emulsão obtida no comércio e formulada em laboratório. A espectrofotometria no UV por derivada de primeira ordem foi padronizada usando-se o método do zero pico a 257 nm, utilizando metanol como solvente. A cromatografia líquida foi realizada empregando-se uma coluna LiChrospher® 100 RP-18 (5 µm). A fase móvel utilizada foi a mistura de trietilamina em metanol (1:500) e solução de acetato de amônio em água (1:200) na proporção de 75:25 v/v, com vazão de 1 mL/min e detecção no UV de 225 nm. O tempo de retenção do cetoconazol foi de 3,9 min e do terconazol de 5,9 min, este último utilizado com padrão interno. As curvas analíticas mostraram linearidade dentro das concentrações de 5,0 a 30,0 µg/mL para o Método I e 20,0 a 80,0 µg/mL para o Método II, com coeficientes de correlação linear de 0,9997 e 0,9981, respectivamente.O desvio padrão relativo (DPR) foi de 0,56% e 0,41% para a amostra simulada e comercial, respectivamente, empregando-se o Método I. Para o Método II, os valores foram de 2,13% e 1,25%, respectivamente. A porcentagem de recuperação foi de 100,1% para o Método I e 100,4% para o Método II. Os excipientes não interferiram nas análises. Os resultados mostraram que os dois métodos podem ser usados para a determinação rápida de cetoconazol em formulações de emulsões com precisão, exatidão e especificidade

1 April 2002 in International Journal of Cosmetic Science
Verified
Journal Article
Closed access
PDF file
EDE. A. Dutra
E. A. Dutra
EKE. R. M. Kedor-Hackmann
E. R. M. Kedor-Hackmann
MSM. I. R. M. Santoro
M. I. R. M. Santoro

1 November 2009 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Open access
PDF file
RSRenata Soares
Renata Soares
ASAnil Kumar Singh
Anil Kumar Singh
EKErika Rosa Maria Kedor-Hackmann
Erika Rosa Maria Kedor-Hackmann
MSMaria Inês Rocha Miritello Santoro
Maria Inês Rocha Miritello Santoro
Many therapeutic agents are commercialized under their racemic form. The enantiomers can show differences in the pharmacokinetic and pharmacodynamic profile. The use of a pure enantiomer in pharmaceutical formulations may result in a better therapeutic index and fewer adverse effects. Atropine, an alkaloid of Atropa belladonna, is a racemic mixture of l-hyoscyamine and d-hyoscyamine. It is widely used to dilate the pupil. To quantify these enantiomers in ophthalmic solutions, an HPLC method was developed and validated using a Chiral AGP column at 20C. The mobile phase consisted of a buffered phosphate solution (containing 10 mM 1-octanesulfonic acid sodium salt and 7.5 mM triethylamine, adjusted to pH 7.0 with orthophosphoric acid) and acetonitrile (99 + 1, v/v). The flow rate was 0.6 mL/min, with UV detection at 205 nm. In the concentration range of 14.026.0 g/mL, the method was found to be linear (r > 0.9999), accurate (with recovery of 100.1100.5), and precise (RSD system 0.6; RSD intraday 1.1; RSD interday 0.9). The method was specific, and the standard and sample solutions were stable for up to 72 h. The factorial design assures robustness with a variation of 10 in the mobile phase components and 2C of column temperature. The complete validation, including stress testing and factorial design, was studied and is presented in this research.