Background: Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years and several locations are equipped with these devices. Aim: The aim of the study was to assess real-life availability of AEDs and assess possible sources of delay. Methods: The study took place in an academic town of Poznan, Lodz and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. Results: From approximately 200 locations that have AED’s, 78 sites were analyzed. In most places the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 [IQR, 7-24] (range: 2-163m). The total time required to deliver the device was 96 [IQR, 52-144]s. The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 [IQR; 0-49]s. The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel and in 29 cases AED utilization required the continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p<0.001), however this did not cause any significant delay in therapy (p=0.132). The AED was clearly visible in 34 sites (43.6%). The visibility of AED did not influence the total time of simulated AED implementation. Conclusions: We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation in under 3 minutes from the onset of the cardiac arrest, however there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets. Background: Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years and several locations are equipped with these devices. Aim: The aim of the study was to assess real-life availability of AEDs and assess possible sources of delay. Methods: The study took place in an academic town of Poznan, Lodz and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. Results: From approximately 200 locations that have AED’s, 78 sites were analyzed. In most places the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 [IQR, 7-24] (range: 2-163m). The total time required to deliver the device was 96 [IQR, 52-144]s. The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 [IQR; 0-49]s. The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel and in 29 cases AED utilization required the continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p<0.001), however this did not cause any significant delay in therapy (p=0.132). The AED was clearly visible in 34 sites (43.6%). The visibility of AED did not influence the total time of simulated AED implementation. Conclusions: We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation in under 3 minutes from the onset of the cardiac arrest, however there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets.
Background. Successful defibrillation is commonly followed by a transient nonperfusing state. To provide perfusion in this stagnant phase, chest compressions are recommended irrespective of arrhythmia termination. Implantable cardioverters-defibrillators (ICD) used immediately after delivery of the shock are capable of pacing the heart, and this feature is commonly activated in these devices. Potential utility of external, transcutaneous postshock pacing in patients with SCA in shockable rhythms has not been determined. This study aimed at presenting an impact of a short-term external postshock pacing (ePSP) on a quality of chest compressions (CC) without compromising them. Methods. The study was designed as a high-fidelity simulation study. Twenty triple-paramedic teams were invited. Participants were asked to take part in a 10-minute adult cardiac arrest scenario with ventricular fibrillation. In the first simulation, paramedics had to resume compressions after each shock (control group). In the second, simultaneous with compressions, one of the rescuers started transcutaneous pacing (TCP) with a current output of 200 mA and a pacer rate of 80 ppm. TCP was finished after 30 seconds (experimental group). The primary outcomes were chest compression fraction (CCF), mean depth and rate of compressions, percent of fully recoiled compressions, and percent of compressions of correct depth and their rate. Results. In both experimental and control group, CCF, mean depth, and rate were similar (84.65 ± 3.67 vs. 85.45 ± 4.95, ; 55.75 ± 3.40 vs. 55.25 ± 2.73, ; 122.70 ± 4.92 vs. 120.80 ± 6.00, , respectively). In turn, percent of CC performed in correct depth, rate, and recoil was unsatisfactory in both groups (51.00 ± 17.40 vs. 52.60 ± 18.72, ; 122.70 ± 4.92 vs. 120.80 ± 6.00, , respectively). Small differences were not statistically significant. Moreover, appropriate hand-positioning was observed more frequently in the control group, and this was the only significant difference (95.60 ± 5.32 vs. 99.30 ± 1.59, ). Conclusion. This difference was statistically significant ( ). Introducing an ePSP does not influence relevantly the quality of CC.
Background: The number of patients with implantable cardioverter‐defibrillators (ICDs) is steadily increasing, making encounters with ICD‐related emergencies more frequent in prehospital care. Paramedics are often the first healthcare professionals to manage these situations; however, data on their exposure to ICD‐related emergencies and access to appropriate equipment remain limited. This study aimed to describe Polish paramedics’ self‐reported experience with ICD‐related emergencies and the availability of ICD deactivation magnets in prehospital settings. Methods: A descriptive cross‐sectional survey was conducted among Polish paramedics between April and November 2024 using an anonymous online questionnaire. The survey assessed demographic and professional characteristics, self‐reported exposure to ICD‐related emergencies, perceived familiarity with selected ICD‐related concepts, and access to ICD deactivation magnets. Data were analyzed descriptively, with exploratory subgroup analyses performed for selected variables. Results: A total of 340 paramedics participated in the survey. Most respondents reported having assisted patients experiencing ICD discharges, including during cardiopulmonary resuscitation. Self‐reported familiarity with ICD‐related terminology and ECG features varied across items. Only 7.93% of respondents reported access to an ICD deactivation magnet in their ambulance, most often self‐provided rather than officially supplied. Greater professional experience was associated with more frequently reported exposure to ICD‐related emergencies. Conclusions: Our study suggests that ICD‐related emergencies are commonly encountered in prehospital practice, while access to ICD deactivation magnets remains limited. The findings reflect self‐reported experience and perceived familiarity rather than objectively assessed competence and highlight potential system‐level considerations for prehospital emergency care.
1 January 2025 in Emergency Medicine International
Following an administered shock in cardiac arrest, the heart commonly experiences a short phase of inability to efficiently perfuse. Despite being a commonly used feature in the ICD population, postshock pacing (PSP) is yet to be adequately explored for its utility in this pulseless phase. Notably, an overwhelming proportion of available data for transcutaneous pacing in spontaneous cardiac arrest stem from the 1980s and 1990s and revolve largely around nonshockable, as opposed to shockable rhythms. The lack of large‐scale clinical trials assessing the efficacy of transcutaneous PSP and the considerable advancements in technology and training facilities since the 1990s indicates a need for reevaluation of current understanding of PSP and its applicability in cardiac arrest. Shedding light into the possible implications of transcutaneous PSP in emergency setting cardiac arrest may not only reshape the current protocols of ALS but also carry the potential of improving survival rates. This concise review serves as a summary of the existing knowledge on the subject of PSP and reveals further possible directions for the development of this therapy.
Every procedural facilitation or a change in available equipment in treatment of out-of-hospital arrest (OHCA) by two-person teams may significantly enhance their performance quality. The aim of this study was to assess the impact of adrenaline in prefilled syringes on improving the adherence to Advanced Life Support protocol by understaffed teams. The research was based on a randomized cross-over high-fidelity simulation study. Two-person teams took part in two 10-minute simulation scenarios featuring sudden cardiac arrest in ventricular fibrillation (VF). The control group (group C) had at its disposal standard ampoules, whereas the experimental group (group E) prefilled syringes. The execution times of CPR start, defibrillation shocks, intravenous (IV) access, epinephrine and amiodarone doses were measured. Additionally, the chest compression fraction (CCF) was calculated. The designed two-minute loops were considerably prolonged in group C. Nineteen teams (31.1%) in group C but 49 (80.3%) in group E carried out the fifth defibrillation (P < 0.001). After two minutes of CPR nobody in group C switched to perform chest compressions. IV access was obtained significantly earlier in group E (114.7 ± 52.2 sec) than in group C (150.2 ± 68.6 sec)(P = 0.002). Two doses of adrenaline were administered in group E, whereas its second dose only by 12 teams in group C. The simulation study has proved that for understaffed teams a use of prefilled syringes not only did enhance the flow of ALS procedure, but it also improved the quality of cardiopulmonary resuscitation.