Maciej Sip

Maciej Sip

Auto-generated profile, based on publicly available information

Maciej Sip

Department of Medical Rescue, Poznan University of Medical Sciences, Poznan, Poland

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2018 in Polish Heart Journal
Verified
Journal Article
Open access
PDF file
WTWojciech Telec
Wojciech Telec
ABArtur Baszko
Artur Baszko
MDMarek Dabrowski
Marek Dabrowski
ADAgata Dąbrowska
Agata Dąbrowska
MSMaciej Sip
Maciej Sip
Lukasz SzarpakLukasz Szarpak
Lukasz Szarpak
Background: Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years and several locations are equipped with these devices. Aim: The aim of the study was to assess real-life availability of AEDs and assess possible sources of delay. Methods: The study took place in an academic town of Poznan, Lodz and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. Results: From approximately 200 locations that have AED’s, 78 sites were analyzed. In most places the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 [IQR, 7-24] (range: 2-163m). The total time required to deliver the device was 96 [IQR, 52-144]s. The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 [IQR; 0-49]s. The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel and in 29 cases AED utilization required the continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p<0.001), however this did not cause any significant delay in therapy (p=0.132). The AED was clearly visible in 34 sites (43.6%). The visibility of AED did not influence the total time of simulated AED implementation. Conclusions: We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation in under 3 minutes from the onset of the cardiac arrest, however there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets. Background: Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years and several locations are equipped with these devices. Aim: The aim of the study was to assess real-life availability of AEDs and assess possible sources of delay. Methods: The study took place in an academic town of Poznan, Lodz and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. Results: From approximately 200 locations that have AED’s, 78 sites were analyzed. In most places the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 [IQR, 7-24] (range: 2-163m). The total time required to deliver the device was 96 [IQR, 52-144]s. The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 [IQR; 0-49]s. The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel and in 29 cases AED utilization required the continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p<0.001), however this did not cause any significant delay in therapy (p=0.132). The AED was clearly visible in 34 sites (43.6%). The visibility of AED did not influence the total time of simulated AED implementation. Conclusions: We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation in under 3 minutes from the onset of the cardiac arrest, however there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets.

27 June 2017 in Perfusion
Verified
Journal Article
Closed access
MPMateusz Puslecki
Mateusz Puslecki
MLMarcin Ligowski
Marcin Ligowski
MDMarek Dabrowski
Marek Dabrowski
MSMaciej Sip
Maciej Sip
SSSebastian Stefaniak
Sebastian Stefaniak
MJMarek Jemielity
Marek Jemielity
Maintaining the viability of organs from donors after circulatory death (DCD) for transplantation is a complicated procedure, from a time perspective in the absence of appropriate organizational capabilities, that makes such transplantation cases difficult and not yet widespread in Poland. We present the procedural preparation for Poland’s first case of organ (kidney) transplantation from a DCD donor in which perfusion was supported by extracorporeal membrane oxygenation (ECMO). Because this organizational model is complex and expensive, we used advanced high-fidelity medical simulation to prepare for the real-life implementation. The real time scenario included all crucial steps: prehospital identification, cardiopulmonary resuscitation (CPR), advanced life support (ALS); perfusion therapy (CPR-ECMO or DCD-ECMO); inclusion and exclusion criteria matching, suitability for automated chest compression; DCD confirmation and donor authorization, ECMO organs recovery; kidney harvesting. The success of our first simulated DCD-ECMO procedure in Poland is reassuring. Soon after this simulation, Maastricht category II DCD procedures were performed, involving real patients and resulting in two successful double kidney transplantations. During debriefing, it was found that the previous simulation-based training provided the experience to build a successful procedural chain, to eliminate errors at the stage of identification, notification, transportation, donor qualifications and ECMO organ perfusion to create DCD-ECMO algorithm architecture.

16 December 2020 in Perfusion
Verified
Journal Article
Closed access
PDF file
MSMaciej Sip
Maciej Sip
MPMateusz Puslecki
Mateusz Puslecki
MDMarek Dabrowski
Marek Dabrowski
TKTomasz Klosiewicz
Tomasz Klosiewicz
RZRadoslaw Zalewski
Radoslaw Zalewski
BPBartłomiej Perek
Bartłomiej Perek
Background: The outcomes of out-of-hospital cardiac arrest (OHCA) patients are poor. In some OHCA cases, the reason is potentially reversible cardiac or aortic disease. It was suggested previously that high-quality cardiopulmonary resuscitation (CPR) followed by extracorporeal membrane oxygenation (ECMO) support may improve the grave prognosis of OHCA. However, extended CPR (ECPR) with ECMO application is an extremely invasive and cutting-edge procedure. The purpose of this article is to describe how high-fidelity medical simulation as a safe tool enabled implementation of the complex, multi-stage ECPR procedure. Method: A high fidelity simulation of OHCA in street conditions was prepared and carried out as part of a ECPR procedure implemented in an in-hospital area. The simulation tested communication and collaboration of several medical teams from the pre-hospital to in-hospital phases along with optimal use of equipment in management of a sudden cardiac arrest (SCA) patient. Results: The critical and weak points of an earlier created scenario were collected into a simulation scenario checklist of ECPR algorithm architecture. A few days later, two ECPR procedures followed by cardiologic interventions for OHCA patients (one pulmonary artery embolectomy for acute pulmonary thrombosis and one percutaneous coronary artery angioplasty with drug eluting stent implantation for acute occlusion of the left anterior descending artery), were performed for the first time in Poland. The protocol was activated five times in the first 2 months of the POHCA Program. Conclusion: High fidelity medical simulation in real-life conditions was confirmed to be a safe, useful tool to test and then implement the novel and complex medical procedures. It enabled to find, analyze and solve the weakest points of the earlier developed theoretical protocol and eventually succeed in clinical application of complete ECPR procedure.

24 May 2017 in Disaster and Emergency Medicine Journal
Verified
Journal Article
Open access
MSMaciej Sip
Maciej Sip
ADAgata Dabrowska
Agata Dabrowska
KPKarina Prucnal
Karina Prucnal
MPMateusz Puslecki
Mateusz Puslecki
TKTomasz Kłosiewicz
Tomasz Kłosiewicz

1 January 2017 in Polish Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
TKTomasz Kłosiewicz
Tomasz Kłosiewicz
MPMateusz Puslecki
Mateusz Puslecki
MZMarcin Zieliński
Marcin Zieliński
MMMichał Mandecki
Michał Mandecki
MLMarcin Ligowski
Marcin Ligowski
MJMarek Jemielity
Marek Jemielity
The number of people waiting for a kidney or liver transplant is growing systematically. Due to the latest advances in transplantation, persons after irreversible cardiac arrest and confirmation of death have become potential organ donors. It is estimated that they may increase the number of donations by more than 40%. However, without good organization and communication between pre-hospital care providers, emergency departments, intensive care units and transplantation units, it is almost impossible to save the organs of potential donors in good condition. Various systems, including extracorporeal membrane oxygenation (ECMO), supporting perfusion of organs for transplantation play a key role. In 2016 the “ECMO for Greater Poland” program was established. Although its main goal is to improve the survival rate of patients suffering from life-threatening cardiopulmonary conditions, one of its branches aims to increase the donation rate in patients with irreversible cardiac arrest. In this review, the role of ECMO in the latter group as the potential organ donors is presented.

1 September 2014 in Polish Annals of Medicine
Verified
Journal Article
Closed access
MZMarcin Zieliński
Marcin Zieliński
ISIlona Skitek-Adamczak
Ilona Skitek-Adamczak
MSMaciej Sip
Maciej Sip
MWMagdalena Witt
Magdalena Witt