Improved ranging accuracy is obtained by the development of a novel ultrasonic sensor ranging algorithm, unlike the conventional ranging algorithm, which considers the divergence angle and the incidence angle of the ultrasonic sensor synchronously. An ultrasonic sensor scanning method is developed based on this algorithm for the recognition of an inclined plate and to obtain the localization of the ultrasonic sensor relative to the inclined plate reference frame. The ultrasonic sensor scanning method is then leveraged for the omni-directional localization of a mobile robot, where the ultrasonic sensors are installed on a mobile robot and follow the spin of the robot, the inclined plate is recognized and the position and posture of the robot are acquired with respect to the coordinate system of the inclined plate, realizing the localization of the robot. Finally, the localization method is implemented into an omni-directional scanning localization experiment with the independently researched and developed mobile robot. Localization accuracies of up to ±3.33 mm for the front, up to ±6.21 for the lateral and up to ±0.20° for the posture are obtained, verifying the correctness and effectiveness of the proposed localization method.
In the macro/micro dual-drive rotary system, the micro-drive system compensates for the position error of the macro-drive system. To realize the sub-arc-second (i.e., level of 1″–0.1″) positioning of the macro/micro dual-drive rotary system, it is necessary to study the positioning performance of the sub-arc-second micro-drive rotary system. In this paper, we designed a sub-arc-second micro-drive rotary system consisting of a PZT (piezoelectric actuator) and a micro rotary mechanism, and used simulation and experimental methods to study the positioning performance of the system. First, the micro-drive rotary system was developed to provide ultra-precise rotary motion. In this system, the PZT has ultrahigh resolution at a level of 0.1 nanometers in linear motion; a micro rotating mechanism was designed according to the composite motion principle of the flexible hinge, which could transform the linear motion of piezoelectric ceramics into rotating motion accurately. Second, the drive performance was analyzed based on the drive performance experiment. Third, kinematics, simulation, and experiments were carried out to analyze the transformation performance of the system. Finally, the positioning performance equation of the system was established based on the two performance equations, and the maximum rotary displacements and positioning error of the system were calculated. The study results showed that the system can provide precision motion at the sub-arc-second and good linearity of motion. This study has a certain reference value in ultra-precision positioning and micromachining for research on rotary motion systems at the sub-arc-second level.
In this paper, a sub-arc-second macro/micro dual-drive rotary system is designed, and the continuous compensation of the system error and its experimental research are completed. First, the macro-drive system is driven by a direct-drive motor, and the micro-drive system uses a piezoelectric ceramic to drive the micro-drive rotary mechanism; the system uses a micro-drive system to compensate the motion error of the macro-drive system, and uses circular grating to feedback the displacement of the macro/micro total output turntable to form a macro/micro dual-drive closed-loop control system. Second, based on the establishment of the system error model, the design of the system’s continuous error compensation scheme is completed. Finally, the positioning accuracy testing of the system, direct error compensation of the macro-drive, manual error compensation of the macro-drive, error compensation performance of the micro-drive part and macro/micro compensation of the system are carried out in the study. The results show that the repeated positioning error and the positioning error of the system are reduced by 78.8% and 95.2%, respectively, after macro/micro compensation. The correctness and effectiveness of the designed system design, error compensation and control method are verified through performance tests, and its positioning accuracy is verified to the sub-arc-second (0.1 arcsecond) level. The research in this paper has important reference value for the development of ultra-precision macro/micro dual-drive technology.