Gabriela Alexe

Gabriela Alexe

Auto-generated profile, based on publicly available information

Gabriela Alexe

Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28 359 Bremen, Germany

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2004 in Physica Status Solidi (b)
Verified
Journal Article
Closed access
PDF file
CKC. Kruse
C. Kruse
SUS. M. Ulrich
S. M. Ulrich
GAG. Alexe
G. Alexe
ERE. Roventa
E. Roventa
Roland KroegerRoland Kroeger
Roland Kroeger
DHD. Hommel
D. Hommel

29 December 2004 in Physical Review B
Verified
Journal Article
Closed access
PDF file
SSS. Schumacher
S. Schumacher
GCG. Czycholl
G. Czycholl
FJF. Jahnke
F. Jahnke
IKI. Kudyk
I. Kudyk
HRH. I. Rückmann
H. I. Rückmann
DHD. Hommel
D. Hommel
Polariton effects due to the interplay of the excitonic polarization of a semiconductor and a propagating light field are studied for transmission spectra of ZnSe∕ZnSxSe1−x heterostructures. Calculations in terms of microscopic boundary conditions for the exciton motion within a finite-height confinement potential can explain the measured transmission spectra. These calculations also show the absence of polarization-free regions near the sample interfaces. Macroscopic models based on Pekar’s additional boundary conditions can only reproduce the spectra if the band alignment at the ZnSe∕ZnSxSe1−x interfaces is modified in comparison to the microscopic calculation and if a sample thickness is used that exceeds the independently determined experimental value. Our findings demonstrate the breakdown of the dead-layer concept for shallow confinement potentials.

5 December 2019 in BioTech
Verified
Journal Article
Open access
PDF file
MSMatthias Steinbacher
Matthias Steinbacher
GAGabriela Alexe
Gabriela Alexe
MBMichael Baune
Michael Baune
IBIlya Bobrov
Ilya Bobrov
IBIngmar Bösing
Ingmar Bösing
Nils EllendtNils Ellendt
Nils Ellendt
The development of novel structural materials with increasing mechanical requirements is a very resource-intense process if conventional methods are used. While there are high-throughput methods for the development of functional materials, this is not the case for structural materials. Their mechanical properties are determined by their microstructure, so that increased sample volumes are needed. Furthermore, new short-time characterization techniques are required for individual samples which do not necessarily measure the desired material properties, but descriptors which can later be mapped on material properties. While universal micro-hardness testing is being commonly used, it is limited in its capability to measure sample volumes which contain a characteristic microstructure. We propose to use alternative and fast deformation techniques for spherical micro-samples in combination with classical characterization techniques such as XRD, DSC or micro magnetic methods, which deliver descriptors for the microstructural state.

1 January 2002 in Physica Status Solidi (b)
Verified
Journal Article
Closed access
PDF file
CKC. Kruse
C. Kruse
GAG. Alexe
G. Alexe
MKM. Klude
M. Klude
HHH. Heinke
H. Heinke
DHD. Hommel
D. Hommel

31 May 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
TSTh. Schmidt
Th. Schmidt
TCT. Clausen
T. Clausen
JFJ. Falta
J. Falta
GAG. Alexe
G. Alexe
TPT. Passow
T. Passow
SBSigrid Bernstorff
Sigrid Bernstorff
The observation and quantitative investigation of the spatial correlation of CdSe quantum dots in stacked CdSe/ZnSSe quantum-dot layers is reported. Using grazing incidence x-ray small angle scattering, the influence of the ZnSSe spacer layer thickness ranging from 20 to 80 Å, as well as the influence of the stacking number (3–10) has been analyzed. Satellite spots, indicative of quantum-dot ordering, have been observed for a spacer thickness of up to 45 Å, and for a stacking number of at least 5. This finding can be explained by a self-organized ordering process driven by the lattice mismatch induced strain. A mean lateral quantum-dot distance ranging from 116 to 145 Å, depending on the spacer thickness, has been found. In addition, an anisotropy of twofold symmetry has been observed, with the strongest correlation signal along 〈11̄0〉.

16 March 2020 in Nanomanufacturing and Metrology
Verified
Journal Article
Open access
PDF file
GAGabriela Alexe
Gabriela Alexe
ATAndreas Tausendfreund
Andreas Tausendfreund
DSDirk Stöbener
Dirk Stöbener
LLLasse Langstädtler
Lasse Langstädtler
MHMarius Herrmann
Marius Herrmann
Andreas FischerAndreas Fischer
Andreas Fischer
The efficient development of new materials with defined properties requires fast methods of testing low volumes of material, such as a high-throughput investigation of spherical metallic micro samples with varying compositions and structuring treatments. A classical material testing method for macro samples, the tensile test cannot be employed for analyzing the mechanical properties of spherical samples with diameters below 1 mm since there are currently no methods for holding and stretching them. A combination between the incremental electrohydraulic extrusion as stress actuation unit and the speckle photography as strain measuring method is presented for obtaining the required mechanical characteristics. Positive longitudinal strain is generated at stepwise extrusion through < 1 mm wide forming channels using a liquid punch and the deformation is observed in situ after each forming step at the interface between the micro sample and a transparent window integrated into the forming die. The occurring local strain fields with a lateral extension down to 100 µm and high gradients require displacement measurements with high lateral resolution over a large range of local dislocations between 0.1 and > 10 µm. It is unknown, whether the speckle strain measuring method is able to provide the necessary low uncertainty for the required resolution in the whole measuring range. Therefore, theoretical and experimental investigations of the deformation measurability using the speckle correlation method are presented, showing that local displacements up to 10 µm can be measured with a spatial resolution between 3 and 10 µm depending on the displacement size. The dominant effect influencing the measurement uncertainty for displacements at this high spatial resolution is the speckle noise, resulting into measurement uncertainties of less than 100 nm. Hence, speckle photography is shown to be applicable for tensile test on micro samples.