ID15A is a newly refurbished beamline at the ESRF devoted to operando and time-resolved diffraction and imaging, total scattering and diffraction computed tomography. The beamline is optimized for rapid alternation between the different techniques during a single operando experiment in order to collect complementary data on working systems. The high available energy (up to 120 keV) means that even bulky and highly absorbing systems may be studied. The beamline is equipped with optimized focusing optics and a photon-counting CdTe pixel detector, allowing for both unprecedented data quality at high energy and for very rapid triggered experiments. A large choice of imaging detectors and ancillary probes and sample environments is also available.
The evolution of crack-tip strain fields in a thin (plane stress) compact tension sample following an overload (OL) event has been studied using two different experimental techniques. Surface behaviour has been characterised by Digital Image Correlation (DIC), while the bulk behaviour has been characterised by means of synchrotron X-ray diffraction (XRD). The combination of both surface and bulk information allowed us to visualise the through-thickness evolution of the strain fields before the OL event, during the overload event, just after OL and at various stages after it. Unlike previous work, complete 2D maps of strains around the crack-tip were acquired at 60?m spatial resolution by XRD. The DIC shows less crack opening after overload and the XRD a lower crack-tip peak stress after OL until the crack has grown past the compressive crack-tip residual stress introduced by the overload after which the behaviour returned to that for the baseline fatigue response. While the peak crack-tip stress is supressed by the compressive residual stress, the crack-tip stress field changes over each cycle are nevertheless the same for all Kmax cycles except at OL.
The properties of the interface between biomaterials and the host tissue play an important role for the process of successful adaptation of implants. Extensive research has focused on shortening the time of osseointegration by modifying the surface in adding a coating such as hydroxyapatite (HAp). We have developed a new type of biocompatible nanohydroxyapatite (n-HAp) coatings, which are characterized before and after deposit on a Ti-6Al-4V substrate using neutron diffraction and scanning electron microscopy. Three months after the implantation in the sheep tibias, high-energy synchrotron radiation (ID15B, ESRF, Grenoble, France) diffraction studies of the cortical bone identify that the c-axes of HAp are preferentially oriented in the direction of the stresses that bone usually withstands. This non destructive analysis of the bone-implant interface proves that bone maturation is achieved successfully with this novel n-HAp coating and demonstrates that the mineralization is completed without spatial organization. None of these findings are obtained with uncoated titanium alloys. The presence of this n-HAp coating on Ti-6Al-4V substrate is decisive in obtaining this mature bone at the interface.