Joe Kelleher

Dr. Joe Kelleher

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2018 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
WKWinfried Kockelmann
Winfried Kockelmann
TMTriestino Minniti
Triestino Minniti
DPDaniel E. Pooley
Daniel E. Pooley
GBGenoveva Burca
Genoveva Burca
RRRanggi Ramadhan
Ranggi Ramadhan
JNJim Nightingale
Jim Nightingale
The cold neutron imaging and diffraction instrument IMAT at the second target station of the pulsed neutron source ISIS is currently being commissioned and prepared for user operation. IMAT will enable white-beam neutron radiography and tomography. One of the benefits of operating on a pulsed source is to determine the neutron energy via a time of flight measurement, thus enabling energy-selective and energy-dispersive neutron imaging, for maximizing image contrasts between given materials and for mapping structure and microstructure properties. We survey the hardware and software components for data collection and image analysis on IMAT, and provide a step-by-step procedure for operating the instrument for energy-dispersive imaging using a two-phase metal test object as an example.

1 August 2019 in Acta Materialia
Verified
Journal Article
Closed access
Pengcheng ZhaoPengcheng Zhao
Pengcheng Zhao
BCB. Chen
B. Chen
JKJoe Kelleher
Joe Kelleher
GYG. Yuan
G. Yuan
BGB. Guan
B. Guan
STS. Tu
S. Tu

1 January 2020 in Acta Materialia
Verified
Journal Article
Closed access
NJNitesh Raj Jaladurgam
Nitesh Raj Jaladurgam
HLHongjia Li
Hongjia Li
JKJoe Kelleher
Joe Kelleher
CPChrister Persson
Christer Persson
ASAxel Steuwer
Axel Steuwer
MCMagnus Hörnqvist Colliander
Magnus Hörnqvist Colliander

20 October 2021 in Metallurgical and Materials Transactions A
Verified
Journal Article
Open access
PDF file
MSM. Sprengel
M. Sprengel
AUAlexander Ulbricht
Alexander Ulbricht
AEA. Evans
A. Evans
AKArne Kromm
Arne Kromm
KSKonstantin Sommer
Konstantin Sommer
TKT. Kannengiesser
T. Kannengiesser
The use of post-processing heat treatments is often considered a necessary approach to relax high-magnitude residual stresses (RS) formed during the layerwise additive manufacturing laser powder bed fusion (LPBF). In this work, three heat treatment strategies using temperatures of 450 °C, 800 °C, and 900 °C are applied to austenitic stainless steel 316L samples manufactured by LPBF. These temperatures encompass the suggested lower and upper bounds of heat treatment temperatures of conventionally processed 316L. The relaxation of the RS is characterized by neutron diffraction (ND), and the associated changes of the microstructure are analyzed using electron backscattered diffraction (EBSD) and scanning electron microscopy (SEM). The lower bound heat treatment variant of 450 °C for 4 hours exhibited high tensile and compressive RS. When applying subsequent heat treatments, we show that stress gradients are still observed after applying 800 °C for 1 hour but almost completely vanish when applying 900 °C for 1 hour. The observed near complete relaxation of the RS appears to be closely related to the evolution of the characteristic subgrain solidification cellular microstructure.

21 June 2019 in Metals
Verified
Journal Article
Open access
PDF file
AGAmy Goodfellow
Amy Goodfellow
LOLewis R. Owen
Lewis R. Owen
Katerina ChristofidouKaterina Christofidou
Katerina Christofidou
JKJoe Kelleher
Joe Kelleher
MHMark Hardy
Mark Hardy
HSHoward Stone
Howard Stone
The lattice parameters and misfit of the γ and γ′ phases in a series of model quaternary Ni-based superalloys with and without Mo additions have been determined using neutron diffraction between room temperature and 700 °C. Despite the fact that Mo is typically expected to partition almost exclusively to the γ phase and thereby increase the lattice parameter of that phase alone, the lattice parameters of both the γ and γ′ phases were observed to increase with Mo addition. Nevertheless, the effect on the γ lattice parameter was more pronounced, leading to an overall decrease in the lattice misfit with increasing Mo content. Alloys with the lowest Mo content were found to be positively misfitting, whilst additions of 5 at.% Mo produced a negative lattice misfit. A general decrease in the lattice misfit with increasing temperature was also observed.

26 March 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
Giulia FestaGiulia Festa
Giulia Festa
TMTriestino Minniti
Triestino Minniti
LALaura Arcidiacono
Laura Arcidiacono
MBMatilde Borla
Matilde Borla
Daniela Di MartinoDaniela Di Martino
Daniela Di Martino
CACarla Andreani
Carla Andreani
Artifacts from the Egyptian grave goods of Kha and Merit preserved at the Museo Egizio in Turin were studied through a combination of non‐destructive and non‐invasive neutron and gamma techniques (namely neutron imaging, neutron diffraction and prompt gamma activation analysis). The results provide unprecedented morphological reconstructions of the inner parts of the two alabaster and metallic vases and their isotopic and phase composition, thereby extending our knowledge of the hitherto unknown content of the vases and their functions.