Rodrigo Peres

Rodrigo Peres

Auto-generated profile, based on publicly available information

Rodrigo Peres

CPQD Research and Development Center in Telecommunications, Campinas, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Fabio BassanFabio Bassan
Fabio Bassan
Joao RosolemJoao Rosolem
Joao Rosolem
Claudio FloridiaClaudio Floridia
Claudio Floridia
BABruno N. Aires
Bruno N. Aires
RPRodrigo Peres
Rodrigo Peres
FFFabiano Fruett
Fabiano Fruett
In this work, we present the design, laboratory tests, and the field trial results of a power-over-fiber (PoF) low power instrument transformer (LPIT) for voltage and current measurements in the medium voltage distribution networks. The new proposed design of this power-over-fiber LPIT aims to overcome the drawbacks presented by the previous technologies, such as the continuous operation (measuring and data transmission) for a wide current range conducted in the medium voltage transmission lines, damage due to lightning strikes, accuracy dependency on vibration, position and temperatures. The LPIT attends the accuracy criteria of IEC 61869-10 and IEC 61869-11 in terms of current and voltage accuracy and it attends the practical criteria adopted by Utilities companies including voltage measurements without removing the coating of the covered conductors. The PoF based LPIT was developed to be applied at 11.9 kV, 13.8 kV, and 23.0 kV phase-to-phase nominal voltages, and in two current ranges 1.25–30 A and 37.5–900 A. The digital data transmission of current, voltage, and temperature from the sensing unit to the processing unit uses a special synchronism technique and it is performed by two 62.5 µm multimode fibers in 850 nm. The optical powering in 976 nm is also performed by one 62.5 µm multimode fiber from the processing unit to the sensor unit. We presented all details of the sensor design and its laboratory characterization in terms of accuracy and temperature correction. We also presented the results of field tests of the sensor made in two different conditions: in a standard distribution network and an experimental hybrid fiber/power distribution network. We believe that these studies aim to incorporate optical fiber and devices, digital technologies, communications systems in electrical systems driving their evolution.

31 May 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Joao RosolemJoao Rosolem
Joao Rosolem
Rivael PenzeRivael Penze
Rivael Penze
Fabio BassanFabio Bassan
Fabio Bassan
Claudio FloridiaClaudio Floridia
Claudio Floridia
RPRodrigo Peres
Rodrigo Peres
MJMarcelo Agra Ramos Junior
Marcelo Agra Ramos Junior
In this work we proposed a sealing method of fiber Bragg grating (FBG) in pressure sensors using electroless nickel-plating. The sensor is designed to be used in harsh environments of thermoelectric power plant engines. In order to be applied in the engine injector nozzle the FBG has just a single attached point in the pressure sensor and the combustion chamber pressure will freely compress the FBG. The fixation material used to seal the FBG in the pressure sensor is the key for the sensor performance considering the engine environment used in thermoelectric power plant. Typical level of pressure in the engine monitoring point is around 200 bar and the temperature exceed 300 °C. We detailed the method of fabrication and the characteristics of this method. Next the FBG pressure sensors using electroless nickel-plating sealing were studied and submitted to laboratorial and field trial evaluation. In addition, we evaluated the signal characteristics of the FBG pressure sensor and we compared it with a standard pressure sensor used in this application.

21 September 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Joao RosolemJoao Rosolem
Joao Rosolem
RPRivael Strobel Penze
Rivael Strobel Penze
Claudio FloridiaClaudio Floridia
Claudio Floridia
FBFabio Renato Bassan
Fabio Renato Bassan
RPRodrigo Peres
Rodrigo Peres
MJMarcelo Agra Ramos Junior
Marcelo Agra Ramos Junior
In this work, we described a study of the influence of dynamical temperatures on pressure measurements in two different packaging types used in FBG pressure sensors. We developed these sensors to measure internal combustion pressure in closed-loop control of thermoelectric engines. The packaging techniques development considered the available monitoring points in the thermoelectric engine and the harsh environment of the monitoring points. In a monitoring point, the temperature can exceed 300 °C and the pressure can reach 250 bar. We detailed the use of single-ended and double-ended FBG fixation methods as packaging techniques. The FBG pressure sensors using these techniques were tested in the laboratory and a thermoelectric engine. The results demonstrated that the dynamical behavior of the high-temperature gas originated from the combustion chamber affects the dynamical pressure measurements performed by the single-ended FBG pressure sensors when they were exposed to the hot gas. This effect can be suppressed by using a double-ended FBG pressure sensor mainly due to its packaging method. Its signal shape is comparable to a reference sensor used in the same condition became this FBG packaging solution the most suitable to use in the closed-loop control of thermoelectric engines.

8 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AMAguinaldo Goes de Melo
Aguinaldo Goes de Melo
DBDaniel Benetti
Daniel Benetti
LLLuiz Alkimin de Lacerda
Luiz Alkimin de Lacerda
RPRodrigo Peres
Rodrigo Peres
Claudio FloridiaClaudio Floridia
Claudio Floridia
Joao RosolemJoao Rosolem
Joao Rosolem
Power transformer is the most important and expensive equipment used in the electric power industry. Fiber Bragg grating (FBG) sensors has stood out as a flexible and particularly suitable tool for power transformer monitoring being a passive and dielectric sensor element. In this work we evaluated the performance of FBG pressure sensors developed to monitor the static and dynamic pressure in high voltage winding transformers during events such as short-circuit and inrush current. Two types of sensors packaging materials were evaluated in laboratory: polyether ether ketone (PEEK) and transformerboard (TB). The sensors have been tested for high intensity and short duration impacts similar to those occurring in short circuits. In addition, we evaluated the time response of sensors using an interrogation system with a 5 kHz sweep in order to analyze the short circuit response time properly. The results pointed that FBG pressure sensors using PEEK and TB are suitable for transformer winding monitoring. The static sensitivity obtained to PEEK based sensors was 0.911 pm/N, in the range of 800 N to 1500 N. This sensitivity is 4.47 higher than TB based sensors sensitivity. Dynamical tests performance showed an excellent repeatability for both sensors, in agreement with static observation.

17 November 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Claudio FloridiaClaudio Floridia
Claudio Floridia
ASArtur Silva
Artur Silva
Joao RosolemJoao Rosolem
Joao Rosolem
FBFabio Renato Bassan
Fabio Renato Bassan
Rivael PenzeRivael Penze
Rivael Penze
MMMarcelo de Moraes
Marcelo de Moraes
This article presents a proposal for an alternative approach for simultaneous measurement of electric current and temperature using an optical sensor based on magnetostrictive material that employs a single Fiber Bragg Grating (FBG). The sensor head is of simple design and allows easy installation on the existing conductors of the underground distribution network. This proposal measures the root mean square (RMS) current from 50 to 600 A at any temperature between 10°C to 60°C, real values for a distribution network. The approach consists of obtaining surface curves of two key parameters of the sensor’s waveform response, $\lambda ({t})$ . The main parameters are the peak-to-peak and minimum wavelengths as a function of temperature and current. When determining these parameters from the waveform, the crossing point of the contour graphics is used to uniquely determine the current and temperature in the sensor head in real-time, without the need for any correction process.

30 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Joao RosolemJoao Rosolem
Joao Rosolem
Rivael PenzeRivael Penze
Rivael Penze
Claudio FloridiaClaudio Floridia
Claudio Floridia
RPRodrigo Peres
Rodrigo Peres
DVDeleon Vasconcelos
Deleon Vasconcelos
MJMarcelo Agra Ramos Junior
Marcelo Agra Ramos Junior
We detail a study of the techniques and sealing materials for optical fiber sensors used in dynamic environments with high pressure (>300 bar) and high temperature (>300 °C). The sealing techniques and materials are the key for the robustness of sensors in harsh dynamic environments, such as large combustion engines. The sealing materials and techniques studied in this work are high-temperature epoxies, metallic polymer, metallic solders, glass solder, cement, brazing and electroless nickel plating. Because obtaining high temperature simultaneously with high pressure is very difficult in the same chamber in the laboratory, we developed a new and simple method to test sealed fibers in these conditions in the laboratory. In addition, some sensors using the materials tested in the laboratory were also field tested in real thermoelectric combustion engines. The study also discusses the methods of fabrication and the cost−benefit ratio of each method.