Dinh Thai Kim

Dinh Thai Kim

Auto-generated profile, based on publicly available information

Dinh Thai Kim

Program of Electrical and Communications Engineering, Feng Chia University, 40724 Taichung, Taiwan

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
DKDinh Thai Kim
Dinh Thai Kim
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
KLKai Che Jack Liu
Kai Che Jack Liu
WHWayne Shih Wei Huang
Wayne Shih Wei Huang
Purpose: The minimally invasive surgery (MIS) has shown advantages when compared to traditional surgery. However, there are two major challenges in the MIS technique: the limited field of view (FOV) and the lack of depth perception provided by the standard monocular endoscope. Therefore, in this study, we proposed a New Endoscope for Panoramic-View with Focus-Area 3D-Vision (3DMISPE) in order to provide surgeons with a broad view field and 3D images in the surgical area for real-time display.Method: The proposed system consisted of two endoscopic cameras fixed to each other. Compared to our previous study, the proposed algorithm for the stitching videos was novel. This proposed stitching algorithm was based on the stereo vision synthesis theory. Thus, this new method can support 3D reconstruction and image stitching at the same time. Moreover, our approach employed the same functions on reconstructing 3D surface images by calculating the overlap region’s disparity and performing image stitching with the two-view images from both the cameras.Results: The experimental results demonstrated that the proposed method can combine two endoscope’s FOV into one wider FOV. In addition, the part in the overlap region could also be synthesized for a 3D display to provide more information about depth and distance, with an error of about 1 mm. In the proposed system, the performance could achieve a frame rate of up to 11.3 fps on a single Intel i5-4590 CPU computer and 17.6 fps on a computer with an additional GTX1060 Nvidia GeForce GPU. Furthermore, the proposed stitching method in this study could be made 1.4 times after when compared to that in our previous report. Besides, our method also improved stitched image quality by significantly reducing the alignment errors or “ghosting” when compared to the SURF-based stitching method employed in our previous study.Conclusion: The proposed system can provide a more efficient way for the doctors with a broad area of view while still providing a 3D surface image in real-time applications. Our system give promises to improve existing limitations in laparoscopic surgery such as the limited FOV and the lack of depth perception.

4 December 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
DKDinh Thai Kim
Dinh Thai Kim
VNVan Thang Nguyen
Van Thang Nguyen
CCChing-Hwa Cheng
Ching-Hwa Cheng
DLDon-Gey Liu
Don-Gey Liu
KLKai Che Jack Liu
Kai Che Jack Liu
KHKai Che Jack Huang
Kai Che Jack Huang
Minimally invasive surgery (MIS) minimizes the surgical incisions that need to be made and hence reduces the physical trauma involved during the surgical process. The ultimate goal is to reduce postoperative pain and blood loss as well as to limit the scarring area and hence accelerate recovery. It is therefore of great interest to both the surgeon and the patient. However, a major problem with MIS is that the field of vision of the surgeon is very narrow. We had previously developed and tested an MIS panoramic endoscope (MISPE) that provides the surgeon with a broader field of view. However, one issue with the MISPE was its low rate of video stitching. Therefore, in this paper, we propose using the region of interest in combination with the downsizing technique to improve the image-stitching performance of the MISPE. Experimental results confirm that, by using the proposed method, the image size can be increased by more than 160%, with the image resolution also improving. For instance, we could achieve performance improvements of 10× (CPU) and 23× (GPU) as compared to that of the original method.

19 November 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
DKDinh Thai Kim
Dinh Thai Kim
CCChing-Hwa Cheng
Ching-Hwa Cheng
DLDon Gey Liu
Don Gey Liu
KLKai-Che Jack Liu
Kai-Che Jack Liu
SHShih Wei Wayne Huang
Shih Wei Wayne Huang
STSONG-TOAN TRAN
SONG-TOAN TRAN
One of the major challenges for Minimally Invasive Surgery (MIS) is the limited field of vision (FOV) of the endoscope. A previous study by the authors designed a MIS Panoramic Endoscope (MISPE) that gives the physician a broad field of view, but this approach is still limited, in terms of performance and quality because it encounters difficulty when there is smoke, specular reflections, or a change in viewpoint. This study proposes a novel algorithm that increases the MISPE’s performance. The method calculates the disparity for the region that is overlapped by the two cameras to allow image stitching. An improved evaluation of the homography matrix uses a frame-by-frame calculation, so the stitched videos are more stable for MIS. The experimental results show that the revised MISPE has a FOV that is 55% greater, and the system operates stably in real time. The proposed system allows a frame rate of 26.7 fps on a single CPU computer. The proposed stitching method is 1.55 times faster than the previous method. The stitched image that is obtained using the proposed method is as similar as the ground truth as the SURF-based stitching method that was used in the previous study.

22 September 2020 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
DKDinh Thai Kim
Dinh Thai Kim
VNVan Thang Nguyen
Van Thang Nguyen
CCChing-Hwa Cheng
Ching-Hwa Cheng
Don-Gey LiuDon-Gey Liu
Don-Gey Liu
KLKai Che Jack Liu
Kai Che Jack Liu
SHShih-Wei Huang
Shih-Wei Huang
In the article titled “Speed Improvement in Image Stitching for Panoramic Dynamic Images during Minimally Invasive Surgery” [1], the name of the last author was given incorrectly as Kai Che Jack Huang. The name should have been written as Shih Wei Wayne Huang, and the revised authors’ list is shown above.