Horst Karl Hahn

Horst Karl Hahn

Auto-generated profile, based on publicly available information

Horst Karl Hahn

Fraunhofer MEVIS

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
HHHenning Höfener
Henning Höfener
AHAndré Homeyer
André Homeyer
NWNick Weiss
Nick Weiss
JMJesper Molin
Jesper Molin
CLClaes F. Lundström
Claes F. Lundström
HHHorst K. Hahn
Horst K. Hahn
Deep convolutional neural networks have become a widespread tool for the detection of nuclei in histopathology images. Many implementations share a basic approach that includes generation of an intermediate map indicating the presence of a nucleus center, which we refer to as PMap. Nevertheless, these implementations often still differ in several parameters, resulting in different detection qualities. We identified several essential parameters and configured the basic PMap approach using combinations of them. We thoroughly evaluated and compared various configurations on multiple datasets with respect to detection quality, efficiency and training effort. Post-processing of the PMap was found to have the largest impact on detection quality. Also, two different network architectures were identified that improve either detection quality or runtime performance. The best-performing configuration yields f1-measures of 0.816 on H&E stained images of colorectal adenocarcinomas and 0.819 on Ki-67 stained images of breast tumor tissue. On average, it was fully trained in less than 15,000 iterations and processed 4.15 megapixels per second at prediction time. The basic PMap approach is greatly affected by certain parameters. Our evaluation provides guidance on their impact and best settings. When configured properly, this simple and efficient approach can yield equal detection quality as more complex and time-consuming state-of-the-art approaches.

10 December 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
YLYaou Liu
Yaou Liu
CLC. Lukas
C. Lukas
MSM D Steenwijk
M D Steenwijk
MDM. Daams
M. Daams
AVA. Versteeg
A. Versteeg
HVH. Vrenken
H. Vrenken
BACKGROUND AND PURPOSE: Spinal cord atrophy is a common and clinically relevant characteristic in multiple sclerosis. We aimed to perform a multicenter validation study of mean upper cervical cord area measurements in patients with multiple sclerosis and healthy controls from head MR images and to explore the effect of gadolinium administration on mean upper cervical cord area measurements. MATERIALS AND METHODS: We recruited 97 subjects from 3 centers, including 60 patients with multiple sclerosis of different disease types and 37 healthy controls. Both cervical cord and head 3D T1-weighted images were acquired. In 11 additional patients from 1 center, head images before and after gadolinium administration and cervical cord images after gadolinium administration were acquired. The mean upper cervical cord area was compared between cervical cord and head images by using intraclass correlation coefficients (ICC) for both consistency (ICCconsist) and absolute (ICCabs) agreement. RESULTS: There was excellent agreement of mean upper cervical cord area measurements from head and cervical cord images in the entire group (ICCabs = 0.987) and across centers and disease subtypes. The mean absolute difference between the mean upper cervical cord area measured from head and cervical cord images was 2 mm2 (2.3%). Additionally, excellent agreement was found between the mean upper cervical cord area measured from head images with and without gadolinium administration (ICCabs = 0.991) and between the cervical cord and head images with gadolinium administration (ICCabs = 0.992). CONCLUSIONS: Excellent agreement between mean upper cervical cord area measurements on head and cervical cord images was observed in this multicenter study, implying that upper cervical cord atrophy can be reliably measured from head images. Postgadolinium head or cervical cord images may also be suitable for measuring mean upper cervical cord area.

13 August 2013 in Computer Graphics Forum
Verified
Journal Article
Closed access
PDF file
FHFrank Heckel
Frank Heckel
JMJan Hendrik Moltz
Jan Hendrik Moltz
CTChristian Tietjen
Christian Tietjen
HHHorst K. Hahn
Horst K. Hahn

29 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
JEJohanna Enke
Johanna Enke
JMJan Hendrik Moltz
Jan Hendrik Moltz
MDMelvin D'Anastasi
Melvin D'Anastasi
Wolfgang Gerhard KunzWolfgang Gerhard Kunz
Wolfgang Gerhard Kunz
CSChristian Schmidt
Christian Schmidt
THThomas Huber
Thomas Huber
The spleen is often involved in malignant lymphoma, which manifests on CT as either splenomegaly or focal, hypodense lymphoma lesions. This study aimed to investigate the diagnostic value of radiomics features of the spleen in classifying malignant lymphoma against non-lymphoma as well as the determination of malignant lymphoma subtypes in the case of disease presence—in particular Hodgkin lymphoma (HL), diffuse large B-cell lymphoma (DLBCL), mantle-cell lymphoma (MCL), and follicular lymphoma (FL). Spleen segmentations of 326 patients (139 female, median age 54.1 +/− 18.7 years) were generated and 1317 radiomics features per patient were extracted. For subtype classification, we created four different binary differentiation tasks and addressed them with a Random Forest classifier using 10-fold cross-validation. To detect the most relevant features, permutation importance was analyzed. Classifier results using all features were: malignant lymphoma vs. non-lymphoma AUC = 0.86 (p < 0.01); HL vs. NHL AUC = 0.75 (p < 0.01); DLBCL vs. other NHL AUC = 0.65 (p < 0.01); MCL vs. FL AUC = 0.67 (p < 0.01). Classifying malignant lymphoma vs. non-lymphoma was also possible using only shape features AUC = 0.77 (p < 0.01), with the most important feature being sphericity. Based on only shape features, a significant AUC could be achieved for all tasks, however, best results were achieved combining shape and textural features. This study demonstrates the value of splenic imaging and radiomic analysis in the diagnostic process in malignant lymphoma detection and subtype classification.

6 March 2008
Verified
Conference Paper
Open access
PDF file
ASAndrea Schenk
Andrea Schenk
SZStephan Zidowitz
Stephan Zidowitz
HBHolger Bourquain
Holger Bourquain
MHMilo Hindennach
Milo Hindennach
CHChristian Hansen
Christian Hansen
HPHeinz-Otto Peitgen
Heinz-Otto Peitgen
The ability to acquire and store radiological images digitally has made this data available to mathematical and scientific methods. With the step from subjective interpretation to reproducible measurements and knowledge, it is also possible to develop and apply models that give additional information which is not directly visible in the data. In this context, it is important to know the characteristics and limitations of each model. Four characteristics assure the clinical relevance of models for computer-assisted diagnosis and therapy: ability of patient individual adaptation, treatment of errors and uncertainty, dynamic behavior, and in-depth evaluation. We demonstrate the development and clinical application of a model in the context of liver surgery. Here, a model for intrahepatic vascular structures is combined with individual, but in the degree of vascular details limited anatomical information from radiological images. As a result, the model allows for a dedicated risk analysis and preoperative planning of oncologic resections as well as for living donor liver transplantations. The clinical relevance of the method was approved in several evaluation studies of our medical partners and more than 2900 complex surgical cases have been analyzed since 2002.

30 May 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
AHAlessa Hering
Alessa Hering
MWMax Westphal
Max Westphal
AGAnnika Gerken
Annika Gerken
HAHaidara Almansour
Haidara Almansour
MMMichael Maurer
Michael Maurer
FPFelix Peisen
Felix Peisen
Purpose: AI-assisted techniques for lesion registration and segmentation have the potential to make CT-based tumor follow-up assessment faster and less reader-dependent. However, empirical evidence on the advantages of AI-assisted volumetric segmentation for lymph node and soft tissue metastases in follow-up CT scans is lacking. The aim of this study was to assess the efficiency, quality, and inter-reader variability of an AI-assisted workflow for volumetric segmentation of lymph node and soft tissue metastases in follow-up CT scans. Three hypotheses were tested: (H1) Assessment time for follow-up lesion segmentation is reduced using an AI-assisted workflow. (H2) The quality of the AI-assisted segmentation is non-inferior to the quality of fully manual segmentation. (H3) The inter-reader variability of the resulting segmentations is reduced with AI assistance. Materials and methods: The study retrospectively analyzed 126 lymph nodes and 135 soft tissue metastases from 55 patients with stage IV melanoma. Three radiologists from two institutions performed both AI-assisted and manual segmentation, and the results were statistically analyzed and compared to a manual segmentation reference standard. Results: AI-assisted segmentation reduced user interaction time significantly by 33% (222 s vs. 336 s), achieved similar Dice scores (0.80–0.84 vs. 0.81–0.82) and decreased inter-reader variability (median Dice 0.85–1.0 vs. 0.80–0.82; ICC 0.84 vs. 0.80), compared to manual segmentation. Conclusion: The findings of this study support the use of AI-assisted registration and volumetric segmentation for lymph node and soft tissue metastases in follow-up CT scans. The AI-assisted workflow achieved significant time savings, similar segmentation quality, and reduced inter-reader variability compared to manual segmentation.