Stefan Weyer

Stefan Weyer

Auto-generated profile, based on publicly available information

Stefan Weyer

Leibniz University Hannover

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2017 in Reviews in Mineralogy and Geochemistry
Verified
Journal Article
Closed access
PDF file
MAMorten B. Andersen
Morten B. Andersen
CSClaudine H. Stirling
Claudine H. Stirling
SWStefan Weyer
Stefan Weyer
This review focuses on the rapidly growing field of natural 238U/235U variability, largely driven by the technical advances in the measurement of U isotope ratios by mass spectrometry with increasing precision over the last decade. A thorough review on the application of the U-decay series systems within Earth sciences was published in Reviews in Mineralogy and Geochemistry (RiMG) volume 52 in 2003, and will not be discussed further within this review. Instead, this article will first focus on the basic chemical properties of U and the evolution of 238U/235U measurement techniques, before discussing the latest findings and use of this isotopic system to address questions within geochronology, cosmochemistry and Earth sciences. ### Uranium occurrence and properties Uranium constitutes one of the principal long-lived radioactive elements that was formed over the lifetime of the galaxy, then injected into the solar system and Earth when they formed more than 4.5 billion years ago (Ga; Dicke 1969). The discovery of the three naturally occurring radioactive decay chains of U and Th occurred around the start of the twentieth century (Becquerel 1896). The heat production from U decay, together with the decay of Th and K, provides the major radioactive heat source on Earth (e.g., Jaupart and Mareschal 2010). The ultimate decay of U to stable isotopes of Pb also forms the basis of one of the most important geochronometers for dating the Earth and solar system, namely the U–Pb or Pb–Pb dating systems (e.g., Patterson et al. 1955). In nature, U commonly occurs in two oxidation states, U+4 and U+6 (e.g., Langmuir 1978). Intermediate U+5 also occurs naturally, but is generally assumed to be unstable through disproportionation and therefore it is short-lived and uncommon in nature (e.g., Grenthe et al. 1992). Chemical species of U+4 are generally …

18 June 2024 in Environmental Science & Technology
Verified
Journal Article
Closed access
XJXiaocen Jia
Xiaocen Jia
AKAndreas Kaufmann
Andreas Kaufmann
MLMarina Lazarov
Marina Lazarov
BWBing Wen
Bing Wen
SWStefan Weyer
Stefan Weyer
JMJuraj Majzlan
Juraj Majzlan

21 May 2021 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
AKA. B. Kaufmann
A. B. Kaufmann
MLM. Lazarov
M. Lazarov
SKS. Kiefer
S. Kiefer
JMJ. Majzlan
J. Majzlan
SWS. Weyer
S. Weyer
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045‰. The long-term reproducibility for these three materials was better than 0.1‰. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All δ123Sb values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of 123Te on 123Sb can only precisely be corrected for materials with Te/Sb ≤ 0.2. The LA and solution analyses of δ123Sb homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable δ123Sb at small scales, determined with LA-MC-ICP-MS, but homogeneous δ123Sb determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous δ123Sb (≈0.5‰) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1‰ and a spatial resolution of ≈30 μm. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.

20 October 2023 in Mineralium Deposita
Verified
Journal Article
Open access
PDF file
AKAndreas B. Kaufmann
Andreas B. Kaufmann
MLMarina Lazarov
Marina Lazarov
SWStefan Weyer
Stefan Weyer
MŠMartin Števko
Martin Števko
SKStefan Kiefer
Stefan Kiefer
JMJuraj Majzlan
Juraj Majzlan
In this work, we investigated in situ isotopic compositions of antimony (Sb) minerals from two substages of the ore deposits near Pezinok (Slovakia). The δ123Sb values of the primary Sb minerals range from −0.4 and +0.8‰ and increase progressively along the precipitation sequence. In the substage II, the early-formed gudmundite (FeSbS) shows in all sections the lowest δ123Sb values, followed by berthierite (FeSb2S4), stibnite (Sb2S3), and valentinite (Sb2O3) with the heaviest δ123Sb values. A similar trend was observed for the substage III, from the initially-formed stibnite, followed by kermesite (Sb2S2O), valentinite, senarmontite (both Sb2O3), and schafarzikite (FeSb2O4). The evolution can be rationalized by a Rayleigh fractionation model with a starting δ123Sb value in the fluid of +0.3‰, applying the same mineral-fluid fractionation factor to all minerals. Thus, the texturally observed order of mineralization is confirmed by diminishing trace element contents and heavier δ123Sb values in successively crystallized Sb minerals. Antimony in substage III was likely supplied from the oxidative dissolution of stibnite that formed earlier during substage II. The data interpretation, although limited by the lack of reliable mineral-fluid fractionation factors, implies that Sb precipitation within each substage occurred from an episodic metal precipitation, likely associated with a similar Sb isotope fractionation between fluid and all investigated Sb minerals. Large isotopic variations, induced by precipitation from a fluid as a response to temperature decrease, may be an obstacle in deciphering the metal source in hydrothermal ore deposits. However, Sb isotopes appear to be an excellent instrument to enhance our understanding on how hydrothermal systems operate.

7 June 2017 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
MWMona Weyrauch
Mona Weyrauch
MOMartin Oeser
Martin Oeser
ABAnnika Brüske
Annika Brüske
SWStefan Weyer
Stefan Weyer
In this study, an in situ technique for high-precision determination of Ni stable isotope ratios by femtosecond-laser ablation-multicollector-ICP-MS (fs-LA-MC-ICP-MS) was developed. With this technique, the Ni isotope compositions of Ni-bearing steels (NIST RM-1226 and BAM D 184-1) and a Ni-rod (standard 10209 from MAC) were determined, both by fs-LA-MC-ICP-MS analyses and by solution MC-ICP-MS, the latter in order to verify the results of the in situ analyses. The LA-MC-ICP-MS analyses revealed that all analyzed standard materials were homogeneous within analytical uncertainties and may thus be suitable as external standards for Ni isotope determination by in situ analysis of metal phases and sulfides. Bulk solution MC-ICP-MS and LA-MC-ICP-MS analyses of these metals agreed within their analytical uncertainties of 0.03‰ for the solution analyses and <0.1‰ (2SD, over 12 months) for the LA-MC-ICP-MS analyses. These results imply that the accuracy of the in situ analyses of metals is better than 0.1‰. The average of four solution nebulization analyses of the Ni-rod and D 184-1, and of 16 analyses of the NIST RM-1226 material, revealed δ62Ni values of −0.26‰, 0.12‰, and −0.28‰ relative to NIST SRM-986, respectively. In order to show the applicability and potential of the presented method, the Ni and Fe isotope compositions of a kamacite–taenite interface in IAB iron meteorite Canyon Diablo were determined by fs-LA-MC-ICP-MS analyses. The isotope profile reveals lighter Fe isotopes in kamacite than in taenite, while the Ni isotope composition is vice versa. Evolution of the isotope signals along the interface of these metal phases strongly points to diffusion-driven fractionation of Fe and Ni isotopes during the formation of kamacite by the replacement of taenite. Due to Fe–Ni exchange diffusion between taenite and kamacite and the generally faster diffusion of light isotopes compared to heavy isotopes, the remaining taenite is left with heavier Fe and lighter Ni isotope compositions than the newly formed kamacite. Demonstration of such detailed information about the diffusion processes in the kamacite–taenite system was not possible before, due to the lack of an appropriate high-precision and high spatial resolution technique for in situ Ni isotope analyses.

4 July 2023 in Geochimica et Cosmochimica Acta
Verified
Journal Article
Closed access
WLWang Liao
Wang Liao
Xinfu ZhaoXinfu Zhao
Xinfu Zhao
LZLi-Ping Zeng
Li-Ping Zeng
SWStefan Weyer
Stefan Weyer
Chao ZhangChao Zhang
Chao Zhang
FHFrancois Holtz
Francois Holtz