1 August 2013 in Medical Image Analysis
7 May 2013 in IEEE Transactions on Medical Imaging
This paper evaluates five 3D ultrasound tracking algorithms regarding their ability to quantify abnormal deformation in timing or amplitude. A synthetic database of B-mode image sequences modeling healthy, ischemic and dyssynchrony cases was generated for that purpose. This database is made publicly available to the community. It combines recent advances in electromechanical and ultrasound modeling. For modeling heart mechanics, the Bestel-Clement-Sorine electromechanical model was applied to a realistic geometry. For ultrasound modeling, we applied a fast simulation technique to produce realistic images on a set of scatterers moving according to the electromechanical simulation result. Tracking and strain accuracies were computed and compared for all evaluated algorithms. For tracking, all methods were estimating myocardial displacements with an error below 1 mm on the ischemic sequences. The introduction of a dilated geometry was found to have a significant impact on accuracy. Regarding strain, all methods were able to recover timing differences between segments, as well as low strain values. On all cases, radial strain was found to have a low accuracy in comparison to longitudinal and circumferential components.
11 August 2016 in IEEE Journal of Biomedical and Health Informatics
Cardiac magnetic resonance perfusion examinations enable noninvasive quantification of myocardial blood flow. However, motion between frames due to breathing must be corrected for quantitative analysis. Although several methods have been proposed, there is a lack of widely available benchmarks to compare different algorithms. We sought to compare many algorithms from several groups in an open benchmark challenge. Nine clinical studies from two different centers comprising normal and diseased myocardium at both rest and stress were made available for this study. The primary validation measure was regional myocardial blood flow based on the transfer coefficient $(K^{\rm{trans}})$ , which was computed using a compartment model and the myocardial perfusion reserve (MPR) index. The ground truth was calculated using contours drawn manually on all frames by a single observer, and visually inspected by a second observer. Six groups participated and 19 different motion correction algorithms were compared. Each method used one of three different motion models: rigid, global affine, or local deformation. The similarity metric also varied with methods employing either sum-of-squared differences, mutual information, or cross correlation. There were no significant differences in $K^{\rm{trans}}$ or MPR compared across different motion models or similarity metrics. Compared with the ground truth, only $K^{\rm{trans}}$ for the sum-of-squared differences metric, and for local deformation motion models, had significant bias. In conclusion, the open benchmark enabled evaluation of clinical perfusion indices over a wide range of methods. In particular, there was no benefit of nonrigid registration techniques over the other methods evaluated in this study. The benchmark data and results are available from the Cardiac Atlas Project ( www.cardiacatlas.org ).
14 July 2018 in International Journal of Computer Assisted Radiology and Surgery
10 October 2014 in Magnetic Resonance in Medicine
Purpose: To develop and evaluate a practical phase unwrapping method for real‐time phase‐contrast flow MRI using temporal and spatial continuity.Methods: Real‐time phase‐contrast MRI of through‐plane flow was performed using highly undersampled radial FLASH with phase‐sensitive reconstructions by regularized nonlinear inversion. Experiments involved flow in a phantom and the human aorta (10 healthy subjects) with and without phase wrapping for velocity encodings of 100 cm·s−1 and 200 cm·s−1. Phase unwrapping was performed for each individual cardiac cycle and restricted to a region of interest automatically propagated to all time frames. The algorithm exploited temporal continuity in forward and backward direction for all pixels with a “continuous” representation of blood throughout the entire cardiac cycle (inner vessel lumen). Phase inconsistencies were corrected by a comparison with values from direct spatial neighbors. The latter approach was also applied to pixels exhibiting a discontinuous signal intensity time course due to movement‐induced spatial displacements (peripheral vessel zone).Results: Phantom and human flow MRI data were successfully unwrapped. When halving the velocity encoding, the velocity‐to‐noise ratio (VNR) increased by a factor of two.Conclusion: The proposed phase unwrapping method for real‐time flow MRI allows for measurements with reduced velocity encoding and increased VNR. Magn Reson Med 74:964–970, 2015.
3 August 2018 in International Journal of Computer Assisted Radiology and Surgery