Jan Brüning

Jan Brüning

Auto-generated profile, based on publicly available information

Jan Brüning

Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin 1 , Berlin

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JBJan Brüning
Jan Brüning
THThomas Hildebrandt
Thomas Hildebrandt
WHWerner Heppt
Werner Heppt
NSNora Schmidt
Nora Schmidt
HLHans Lamecker
Hans Lamecker
LGLeonid Goubergrits
Leonid Goubergrits
This study’s objective was the generation of a standardized geometry of the healthy nasal cavity. An average geometry of the healthy nasal cavity was generated using a statistical shape model based on 25 symptom-free subjects. Airflow within the average geometry and these geometries was calculated using fluid simulations. Integral measures of the nasal resistance, wall shear stresses (WSS) and velocities were calculated as well as cross-sectional areas (CSA). Furthermore, individual WSS and static pressure distributions were mapped onto the average geometry. The average geometry featured an overall more regular shape that resulted in less resistance, reduced WSS and velocities compared to the median of the 25 geometries. Spatial distributions of WSS and pressure of the average geometry agreed well compared to the average distributions of all individual geometries. The minimal CSA of the average geometry was larger than the median of all individual geometries (83.4 vs. 74.7 mm²). The airflow observed within the average geometry of the healthy nasal cavity did not equal the average airflow of the individual geometries. While differences observed for integral measures were notable, the calculated values for the average geometry lay within the distributions of the individual parameters. Spatially resolved parameters differed less prominently.

3 October 2018 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
JBJan Brüning
Jan Brüning
FHFlorian Hellmeier
Florian Hellmeier
PYPavlo Yevtushenko
Pavlo Yevtushenko
TKTitus Kühne
Titus Kühne
LGLeonid Goubergrits
Leonid Goubergrits

14 November 2023 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
SVSabine Verstraeten
Sabine Verstraeten
MHMartijn Hoeijmakers
Martijn Hoeijmakers
PTPim A.L. Tonino
Pim A.L. Tonino
JBJan Brüning
Jan Brüning
CCClaudio Capelli
Claudio Capelli
WHWouter Huberts
Wouter Huberts
In silico trials are a promising way to increase the efficiency of the development, and the time to market of cardiovascular implantable devices. The development of transcatheter aortic valve implantation (TAVI) devices, could benefit from in silico trials to overcome frequently occurring complications such as paravalvular leakage and conduction problems. To be able to perform in silico TAVI trials virtual cohorts of TAVI patients are required. In a virtual cohort, individual patients are represented by computer models that usually require patient‐specific aortic valve geometries. This study aimed to develop a virtual cohort generator that generates anatomically plausible, synthetic aortic valve stenosis geometries for in silico TAVI trials and allows for the selection of specific anatomical features that influence the occurrence of complications. To build the generator, a combination of non‐parametrical statistical shape modeling and sampling from a copula distribution was used. The developed virtual cohort generator successfully generated synthetic aortic valve stenosis geometries that are comparable with a real cohort, and therefore, are considered as being anatomically plausible. Furthermore, we were able to select specific anatomical features with a sensitivity of around 90%. The virtual cohort generator has the potential to be used by TAVI manufacturers to test their devices. Future work will involve including calcifications to the synthetic geometries, and applying high‐fidelity fluid–structure‐interaction models to perform in silico trials.

14 July 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KVKatharina Vellguth
Katharina Vellguth
JBJan Brüning
Jan Brüning
LGLeonid Goubergrits
Leonid Goubergrits
LTLennart Tautz
Lennart Tautz
AHAnja Hennemuth
Anja Hennemuth
TKTitus Kuehne
Titus Kuehne

12 January 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JFJoao Filipe Fernandes
Joao Filipe Fernandes
LGLeonid Goubergrits
Leonid Goubergrits
JBJan Brüning
Jan Brüning
FHFlorian Hellmeier
Florian Hellmeier
SNSarah Nordmeyer
Sarah Nordmeyer
CCCARDIOPROOF Consortium
CARDIOPROOF Consortium
In aortic coarctation, current guidelines recommend reducing pressure gradients that exceed given thresholds. From a physiological standpoint this should ideally improve the energy expenditure of the heart and thus prevent long term organ damage. The aim was to assess the effects of interventional treatment on external and internal heart power (EHP, IHP) in patients with aortic coarctation and to explore the correlation of these parameters to pressure gradients obtained from heart catheterization. In a collective of 52 patients with aortic coarctation 25 patients received stenting and/or balloon angioplasty, and 20 patients underwent MRI before and after an interventional treatment procedure. EHP and IHP were computed based on catheterization and MRI measurements. Along with the power efficiency these were combined in a cardiac energy profile. By intervention, the catheter gradient was significantly reduced from 21.8±9.4 to 6.2±6.1mmHg (p<0.001). IHP was significantly reduced after intervention, from 8.03±5.2 to 4.37±2.13W (p < 0.001). EHP was 1.1±0.3 W before and 1.0±0.3W after intervention, p = 0.044. In patients initially presenting with IHP above 5W intervention resulted in a significant reduction in IHP from 10.99±4.74 W to 4.94±2.45W (p<0.001), and a subsequent increase in power efficiency from 14 to 26% (p = 0.005). No significant changes in IHP, EHP or power efficiency were observed in patients initially presenting with IHP < 5W. It was demonstrated that interventional treatment of coarctation resulted in a decrease in IHP. Pressure gradients, as the most widespread clinical parameters in coarctation, did not show any correlation to changes in EHP or IHP. This raises the question of whether they should be the main focus in coarctation interventions. Only patients with high IHP of above 5W showed improvement in IHP and power efficiency after the treatment procedure. clinicaltrials.gov NCT02591940

25 March 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
LGLeonid Goubergrits
Leonid Goubergrits
FHFlorian Hellmeier
Florian Hellmeier
JBJan Bruening
Jan Bruening
ASAndreas Spuler
Andreas Spuler
HHHans-Christian Hege
Hans-Christian Hege
PBPhilipp Berg
Philipp Berg
Geometric parameters have been proposed for prediction of cerebral aneurysm rupture risk. Predicting the rupture risk for incidentally detected unruptured aneurysms could help clinicians in their treatment decision. However, assessment of geometric parameters depends on several factors, including the spatial resolution of the imaging modality used and the chosen reconstruction procedure. The aim of this study was to investigate the uncertainty of a variety of previously proposed geometric parameters for rupture risk assessment, caused by variability of reconstruction procedures. 26 research groups provided segmentations and surface reconstructions of five cerebral aneurysms as part of the Multiple Aneurysms AnaTomy CHallenge (MATCH) 2018. 40 dimensional and non-dimensional geometric parameters, describing aneurysm size, neck size, and irregularity of aneurysm shape, were computed. The medians as well as the absolute and relative uncertainties of the parameters were calculated. Additionally, linear regression analysis was performed on the absolute uncertainties and the median parameter values. A large variability of relative uncertainties in the range between 3.9 and 179.8% was found. Linear regression analysis indicates that some parameters capture similar geometric aspects. The lowest uncertainties < 6% were found for the non-dimensional parameters isoperimetric ratio, convexity ratio, and ellipticity index. Uncertainty of 2D and 3D size parameters was significantly higher than uncertainty of 1D parameters. The most extreme uncertainties > 80% were found for some curvature parameters. Uncertainty analysis is essential on the road to clinical translation and use of rupture risk prediction models. Uncertainty quantification of geometric rupture risk parameters provided by this study may help support development of future rupture risk prediction models.