12 July 2023 in IET Renewable Power Generation
The inter‐turn short‐circuit fault of a power transformer has a large current in the winding, which will cause serious heating and deformation of the winding and may threaten the safety of the power transformer. Under this background, this paper proposes a scheme based on open‐delta voltage monitoring and identification of inter‐turn short circuits in power transformers. First, the mathematical modeling and analysis of the principle of inter‐turn short‐circuit monitoring of power transformers are carried out, and the mathematical expression to characterize power transformers with different short‐circuit turns are given. Second, the magnetic field distribution of the power transformer under different short‐circuit conditions, the relationship between the eigenvalue and the number of short‐circuit turns etc. are given. Finally, the experimental study verifies the correctness of the proposed scheme.
2 January 2025 in IEEE Transactions on Instrumentation and Measurement
Studies have shown that the superposition of the third harmonic on the fundamental frequency significantly impacts the magnetic characteristics and magnetostriction behavior of the three-dimensional wound core transformer. Specifically, as the amplitude, phase, and content of the third harmonic increase, local hysteresis loops emerge in the core’s magnetic hysteresis curve, and magnetostriction intensifies. These effects lead to flux distortion, increased losses, and potential risks of local overheating and noise, compromising the stable operation of the transformer. In this context, this paper investigates the magnetic and magnetostriction characteristics of a three-dimensional wound core transformer (380V/220V/50kVA) under the influence of fundamental and zero-sequence harmonics. A mathematical model combining the Everett, Mayergoyz, and Preisach (EMP) approaches is proposed to describe the magnetic and magnetostriction properties. The research examines the impact of third harmonic content and phase on the magnetic and magnetostriction characteristics of the transformer core’s electrical steel (grade: 20SQG090). Experiments were conducted to analyze these characteristics under varying harmonic content and phase conditions. The study provides curves depicting the magnetic properties, magnetostriction behavior, and losses of 20SQG090 oriented electrical steel for different harmonic scenarios, laying the foundation for further investigation into transformer vibration considering magnetostriction effects.
11 November 2022 in IET Power Electronics
This paper proposes an LLC‐DAB integrated high‐frequency isolated DC–DC converter topology structure to reduce the loss and cost of the DC power distribution system. Furthermore, the complexity and efficiency of the system also can be improved. The proposed converter consists of a DAB converter and two input‐parallel‐output‐parallel half‐bridge LLC resonant converters. It provides two DC voltage level buses, namely the HVDC bus and the LVDC bus. Compared with the typical converter topology of the DC power distribution system, the number of power semiconductors of the proposed converter topology is reduced by sharing the power semiconductors of the DAB converter and LLC resonant converter. As a result, with the number of power semiconductors decreasing, the cost and loss of the system are reduced. Moreover, the proposed converter can control the flow direction of power conversion and supply power to the loads. The single‐phase‐shift modulation method is adopted for the DAB converter, and two LLC resonant converters operate as the DC transformer under resonant frequency with open‐loop control. The operation principles and characteristics of the proposed converter are discussed. Finally, the simulation is carried out and an experimental prototype is developed to verify the effectiveness of the proposed topology.
13 March 2022 in IET Power Electronics
In order to solve the problems of poor thermal stability and high frequency noise of transformer in traditional DC‐DC converter, the medium frequency transformer in isolated DC‐DC converter is designed and studied, which adopts 0.15 mm ultra‐thin silicon steel sheet. Firstly, the magnetism of ultra‐thin silicon steel is measured by using single‐piece silicon steel sheet measuring device, and the B‐H curves and B‐P curves at different frequencies are given. According to the magnetic measurement results, the electromagnetic scheme of three port medium frequency transformer is designed by AP method and applied the particle swarm algorithm to further design under the constraint of loss minimization. Secondly the three‐winding transformer of DC‐DC converter is optimized and simulated. The magnetic flux density, loss, temperature field distribution, output voltage and current waveform of the transformer under different working conditions are given. Finally, the 20 kW DC‐DC converter was manufactured and the magnetic characteristics of the medium frequency transformer were experimented to verify the correctness of the proposed scheme.