Tomasz Horwacik

Tomasz Horwacik

Auto-generated profile, based on publicly available information

Tomasz Horwacik

Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Kraków, Poland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JHJan Hrbacek
Jan Hrbacek
KMKavita K. Mishra
Kavita K. Mishra
AKAndrzej Kacperek
Andrzej Kacperek
RDRemi Dendale
Remi Dendale
CNCatherine Nauraye
Catherine Nauraye
DWDamien C. Weber
Damien C. Weber

11 November 2016 in Journal of Space Weather and Space Climate
Verified
Journal Article
Open access
PDF file
TBThomas Berger
Thomas Berger
BPBartos Przybyla
Bartos Przybyla
DMDaniel Matthiä
Daniel Matthiä
GRGünther Reitz
Günther Reitz
SBSönke Burmeister
Sönke Burmeister
MBMatthias Boehme
Matthias Boehme
Journal of Space Weather and Space Climate, a link between all the communities involved in Space Weather and in Space Climate

1 January 2005 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
JSJan Swakoń
Jan Swakoń
KKK. Kozak
K. Kozak
MPM. Paszkowski
M. Paszkowski
RGR. Gradziński
R. Gradziński
JŁJ. Łoskiewicz
J. Łoskiewicz
POP. Olko
P. Olko

1 December 2010 in Radiation Measurements
Verified
Journal Article
Closed access
JSJan Swakoń
Jan Swakoń
POP. Olko
P. Olko
DAD. Adamczyk
D. Adamczyk
TCT. Cywicka-Jakiel
T. Cywicka-Jakiel
JDJ. Dabrowska
J. Dabrowska
MWMichael Waligórski
Michael Waligórski

1 November 2015 in Radiation Measurements
Verified
Journal Article
Closed access
MSMichał Sądel
Michał Sądel
PBPawel Bilski
Pawel Bilski
JSJan Swakoń
Jan Swakoń
MRM. Rydygier
M. Rydygier
THT. Horwacik
T. Horwacik
AWA. Weber
A. Weber

7 January 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
POPawel Olko
Pawel Olko
JSJan Swakoń
Jan Swakoń
THTomasz Horwacik
Tomasz Horwacik
HJHubert Jabłoński
Hubert Jabłoński
FVFilip Vanhavere
Filip Vanhavere
Objective . Treatment planning based on computer simulations was proposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison. Approach . Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10 μ m) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1 μ m water sphere), and published clonogenic survival in vitro RBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR). Main results . Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE 10 up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR. Significance . This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.