Hubert Jabłoński

Hubert Jabłoński

Auto-generated profile, based on publicly available information

Hubert Jabłoński

Cyclotron Centre Bronowice, Institute of Nuclear Physics Polish Academy of Sciences, PL31342 Kraków, Poland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
POPawel Olko
Pawel Olko
JSJan Swakoń
Jan Swakoń
THTomasz Horwacik
Tomasz Horwacik
HJHubert Jabłoński
Hubert Jabłoński
FVFilip Vanhavere
Filip Vanhavere
Objective . Treatment planning based on computer simulations was proposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison. Approach . Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10 μ m) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1 μ m water sphere), and published clonogenic survival in vitro RBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR). Main results . Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE 10 up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR. Significance . This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.

1 January 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
APAlessio Parisi
Alessio Parisi
POPawel Olko
Pawel Olko
JSJan Swakoń
Jan Swakoń
THTomasz Horwacik
Tomasz Horwacik
HJHubert Jabłoński
Hubert Jabłoński
FVFilip Vanhavere
Filip Vanhavere
Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measurements with luminescent detectors. The fluence- and dose-mean unrestricted proton LET were determined along the Bragg peak using a recently developed methodology based on the combination of the response of 7 LiF:Mg,Ti (MTS-7) and 7 LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors. The experimentally assessed LET values were compared with the results of radiation transport simulations using the Monte Carlo code PHITS, showing a good agreement. The cell survival probabilities and RBE were then calculated using the linear-quadratic model with the linear term derived using a phenomenological LET-based model (Carabe A et al 2012 Phys. Med. Biol . 57 1159) in combination with the experimentally-assessed or PHITS-simulated dose mean proton LET values. To the same aim, PHITS simulated microdosimetric spectra were used as input to the modified microdosimetric kinetic model (modified MKM, (Kase et al 2006 Radiat. Res . 166 629–38)). The RBE values calculated with the three aforementioned approaches were compared and found to be in very good agreement between each other, proving that by using dedicated pairs of thermoluminescent detectors it is possible to determine ionization density quantities of therapeutic proton beams which can be applied to predict the local value of the RBE.

1 April 2020 in Radiation Measurements
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
POPawel Olko
Pawel Olko
JSJan Swakoń
Jan Swakoń
THTomasz Horwacik
Tomasz Horwacik
HJHubert Jabłoński
Hubert Jabłoński
FVFilip Vanhavere
Filip Vanhavere

1 March 2020 in Radiation Measurements
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
POPawel Olko
Pawel Olko
JSJan Swakoń
Jan Swakoń
THTomasz Horwacik
Tomasz Horwacik
HJHubert Jabłoński
Hubert Jabłoński
FVFilip Vanhavere
Filip Vanhavere

6 January 2026 in Physica Medica
Verified
Journal Article
Closed access
NMNatalia Mojżeszek
Natalia Mojżeszek
HBHrvoje Brkić
Hrvoje Brkić
GFGabriela Foltyńska
Gabriela Foltyńska
OHOlivier Van Hoey
Olivier Van Hoey
HJHubert Jabłoński
Hubert Jabłoński
MSMarijke De Saint-Hubert
Marijke De Saint-Hubert

3 September 2025 in Physica Medica
Verified
Journal Article
Open access
WKWiktor Komenda
Wiktor Komenda
NMNatalia Mojżeszek
Natalia Mojżeszek
MBMarta Bałamut
Marta Bałamut
JGJan Gajewski
Jan Gajewski
HJHubert Jabłoński
Hubert Jabłoński
ARAntoni Ruciński
Antoni Ruciński
Experimental patient-specific quality assurance (PSQA) in proton therapy is a labor-intensive process requiring physical access to treatment rooms, beam time, and significant human resources. With the increasing complexity of treatment plans and the implementation of adaptive therapy, the need for efficient alternatives is pressing. Simulation-based techniques are proposed as a replacement or enhancement for experimental ones. This study presents a data-driven approach to simulation-based PSQA criteria selection and validation. The FRED Monte Carlo code was used to simulate PSQA for 293 patients (Gantry 1) and 296 patients (Gantry 2), divided into training and verification subsets. The training dataset guided criteria selection for simulation-based PSQA. The gamma index (GI) was analysed with criteria of 3 %/2 mm, 2 %/2 mm, 1.75 %/2 mm, 1.5 %/2 mm and 1.25 %/2 mm and compared to experimental PSQA through Spearman's rank test. Both GI criteria and passing rate thresholds were tested to maximize consistency between experimental and simulation-based PSQA and to minimize the likelihood of false-positive errors. We validated the selected criterion on the verification subset. The analysis identified the 1.75 %/2mm GI criterion with a 95 % passing rate as optimal. Validation on an independent verification dataset of 2816 planes showed high consistency between simulation-based and experimental PSQA: 97.5 % agreement for Gantry 1 and 98.6 % for Gantry 2. False positives were eliminated for Gantry 1 and reduced to 0.5 % for Gantry 2. The proposed approach demonstrates its potential to streamline PSQA workflows, maintain clinical accuracy, and enable the integration of simulation-based PSQA into routine practice.