1 January 2017 in Journal of Vascular Surgery
10 October 2007 in Anz Journal of Surgery
1 September 1994 in Journal of Endovascular Therapy
Purpose: The aim of this study was to analyze the causes of failure of endoluminal grafting for abdominal aortic aneurysms (AAA) and to put forward proposals for preventing these failures. Methods: Since May 1992, endoluminal repair of aneurysms was undertaken in 47 patients. Forty-three of these patients had AAAs and are the basis of this study. All procedures were nonurgent and were performed in the operating room with the patient draped for an open repair in the event of failed endoluminal repair. Radiographic guidance was used to pass the endografts into the aorta via a delivery sheath introduced through the femoral or iliac arteries. The configuration of the endografts was tubular (n = 28), tapered aortoiliac/aorto-femoral (n = 11), and bifurcated (n = 4). Results: Successful endoluminal repair was achieved in 34 of 43 (79%) patients. The remaining nine were terminated in favor of an open repair. The causes of failure were problems with access (2), balloon malfunction (1), stent dislodgment (3), graft thrombosis (1), and inability to deploy the contralateral limb of a bifurcated graft (2). All failed endoluminal repairs proceeded to successful open repair. There was no perioperative mortality in patients undergoing endoluminal repair or in those whose endoluminal repair was converted to open operation. Conclusions: The failures of endoluminal grafting have been analyzed. Methods of avoiding access problems, balloon malfunction, and stent dislodgment have been defined and recommendations made.
1 May 1997 in Journal of Endovascular Therapy
Purpose: To report a > 3-year experience with a modular, balloon-expandable endovascular graft used for aneurysm exclusion in the aorta and other arteries. Methods: The customized White-Yu Endovascular GAD Graft, a woven polyester prosthesis with an intrinsic Elgiloy wire graft attachment system along the body of the graft, is a flexible endograft design available in straight, tapered, and bifurcated versions that can be delivered transluminally through 18F to 24F sheaths. Results: Since July 1993, 93 patients have received the White-Yu endograft for treatment of 76 abdominal aortic, 3 thoracic aortic, 13 iliac, and 1 popliteal aneurysms. Of the 79 aortic procedures, 39 involved straight tube grafts, 20 were tapered aortoiliac models, and 20 were bifurcated devices. Success rates for tube grafts were 81% in the abdominal aorta and 100% for the thoracic aorta; 5 primary endoleaks (14%) and 2 conversions to surgery (5.6%) occurred with this graft type. Aortoiliac grafts were deployed successfully in 95% (19/20) of cases with 1 conversion (5%) due to thrombosis. Seventy-five percent of the bifurcated endograft procedures were successful, with 4 conversions (20%) for technical failures and 1 graft thrombosis. Four additional endografts were deployed to treat two primary and two secondary endoleaks in tube graft patients. Two access-related arterial injuries were treated surgically. There was one case of embolus to the distal femoral artery but no microembolization. Overall perioperative (30-day) mortality was 3.1%. Over a mean 18-month follow-up (range 2 to 39), no late graft thrombosis, stenosis, or graft migration has been seen on CT scans or X ray. Endoleak has not been detected in any aortoiliac or bifurcated graft. Aneurysm size has diminished consistently in successfully treated cases. Conclusions: The White-Yu endograft appears to offer a safe, efficacious, and minimally invasive means of excluding aneurysms from the circulation. Improvements in patient selection, surgical techniques, and equipment have reduced the incidence of endoleak and conversion to open repair over the course of the evaluation.
1 September 1994 in Journal of Endovascular Therapy
Purpose: The aim of this study was to determine the feasibility of endoluminal grafting of aneurysms using a new design of nonstented endograft. Methods: Initial studies were undertaken in bench models and by implantation of endografts into animal vessels. Between May 1992 and June 1994, endoluminal repair of aneurysms was undertaken in 47 patients (44 male, 3 female). A new balloon-expandable endoluminal graft was developed and has now been studied in 25 of these 47 cases. This graft does not require adjunctive use of a vascular stent because of its unique construction, which incorporates metallic implants (graft attachment device or “GAD”) into the graft material. The design is applicable to endovascular grafting of occlusive arterial disease, as well as aneurysms. All patients were investigated by duplex scan, calibrated angiogram, and angio-CT scan and then allocated into groups that we defined according to the following criteria: group I, considered suitable for transfemoral implantation of a straight tube graft (n = 12); group II, unsuitable for transfemoral tube graft because of short neck of aneurysm, absent distal neck, or diseased iliac arteries (n = 10); and group III, peripheral aneurysms (n = 3). All patients were followed by clinical examination, duplex scan, and CT scan, with selective use of angiography. Results: Intraluminal deployment of the graft was achieved in all 25 patients; however, 3 patients from group II subsequently required conversion to open procedures because of the following complications: (1) partial graft thrombosis resulting from inadvertent omission of systemic anticoagulation during deployment (n = 1); and (2) unsuccessful deployment of the contralateral limb of a bifurcated graft in the iliac artery (n = 2). Successful endoluminal repair was achieved in 100% of patients in groups I and III, compared to 70% in group II. Conclusions: These preliminary results (in a series of high-risk patients) have demonstrated that endoluminal abdominal aortic aneurysm repair with this graft can be achieved reliably and with low morbidity in patients who fulfill the selection criteria (group I) and in peripheral aneurysms (group III), but the results were less satisfactory in aneurysms that do not have a good proximal or distal neck or in patients with diseased iliac arteries (group II). Further modification of the bifurcated version of this graft design, together with improvements in access techniques and graft materials, is required for successful endoluminal grafting in a wider range of patients.
1 May 1991 in Annals of Vascular Surgery