Tim McGahan

Tim McGahan

Auto-generated profile, based on publicly available information

Tim McGahan

Department of Vascular Surgery, Princess Alexandra Hospital, Brisbane, QLD, Australia

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in The Lancet Neurology
Verified
Journal Article
Open access
LBLeo H Bonati
Leo H Bonati
JGJohn Gregson
John Gregson
JDJoanna Dobson
Joanna Dobson
DMDominick J H McCabe
Dominick J H McCabe
PNPaul J Nederkoorn
Paul J Nederkoorn
BZBojana Zvan
Bojana Zvan
The risk of stroke associated with carotid artery restenosis after stenting or endarterectomy is unclear. We aimed to compare the long-term risk of restenosis after these treatments and to investigate if restenosis causes stroke in a secondary analysis of the International Carotid Stenting Study (ICSS). ICSS is a parallel-group randomised trial at 50 tertiary care centres in Europe, Australia, New Zealand, and Canada. Patients aged 40 years or older with symptomatic carotid stenosis measuring 50% or more were randomly assigned either stenting or endarterectomy in a 1:1 ratio. Randomisation was computer-generated and done centrally, with allocation by telephone or fax, stratified by centre, and with minimisation for sex, age, side of stenosis, and occlusion of the contralateral carotid artery. Patients were followed up both clinically and with carotid duplex ultrasound at baseline, 30 days after treatment, 6 months after randomisation, then annually for up to 10 years. We included patients whose assigned treatment was completed and who had at least one ultrasound examination after treatment. Restenosis was defined as any narrowing of the treated artery measuring 50% or more (at least moderate) or 70% or more (severe), or occlusion of the artery. The degree of restenosis based on ultrasound velocities and clinical outcome events were adjudicated centrally; assessors were masked to treatment assignment. Restenosis was analysed using interval-censored models and its association with later ipsilateral stroke using Cox regression. This trial is registered with the ISRCTN registry, number ISRCTN25337470. This report presents a secondary analysis, and follow-up is complete. Between May, 2001, and October, 2008, 1713 patients were enrolled and randomly allocated treatment (855 were assigned stenting and 858 endarterectomy), of whom 1530 individuals were followed up with ultrasound (737 assigned stenting and 793 endarterectomy) for a median of 4·0 years (IQR 2·3-5·0). At least moderate restenosis (≥50%) occurred in 274 patients after stenting (cumulative 5-year risk 40·7%) and in 217 after endarterectomy (29·6%; unadjusted hazard ratio [HR] 1·43, 95% CI 1·21-1·72; p<0·0001). Patients with at least moderate restenosis (≥50%) had a higher risk of ipsilateral stroke than did individuals without restenosis in the overall patient population (HR 3·18, 95% CI 1·52-6·67; p=0·002) and in the endarterectomy group alone (5·75, 1·80-18·33; p=0·003), but no significant increase in stroke risk after restenosis was recorded in the stenting group (2·03, 0·77-5·37; p=0·154; p=0·10 for interaction with treatment). No difference was noted in the risk of severe restenosis (≥70%) or subsequent stroke between the two treatment groups. At least moderate (≥50%) restenosis occurred more frequently after stenting than after endarterectomy and increased the risk for ipsilateral stroke in the overall population. Whether the restenosis-mediated risk of stroke differs between stenting and endarterectomy requires further research. Medical Research Council, the Stroke Association, Sanofi-Synthélabo, and the European Union.

2 January 2020 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
JMJessica Benitez Mendieta
Jessica Benitez Mendieta
Davide FontanarosaDavide Fontanarosa
Davide Fontanarosa
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
PPPhani Kumari Paritala
Phani Kumari Paritala
TMTim McGahan
Tim McGahan
ZLZhiyong Li
Zhiyong Li

1 September 1994 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
JMJames May
James May
GWGeoffrey H. White
Geoffrey H. White
WYWeiyun Yu
Weiyun Yu
RWRichard C. Waugh
Richard C. Waugh
TMTimothy McGahan
Timothy McGahan
JHJohn P. Harris
John P. Harris
Purpose: The aim of this study was to analyze the causes of failure of endoluminal grafting for abdominal aortic aneurysms (AAA) and to put forward proposals for preventing these failures. Methods: Since May 1992, endoluminal repair of aneurysms was undertaken in 47 patients. Forty-three of these patients had AAAs and are the basis of this study. All procedures were nonurgent and were performed in the operating room with the patient draped for an open repair in the event of failed endoluminal repair. Radiographic guidance was used to pass the endografts into the aorta via a delivery sheath introduced through the femoral or iliac arteries. The configuration of the endografts was tubular (n = 28), tapered aortoiliac/aorto-femoral (n = 11), and bifurcated (n = 4). Results: Successful endoluminal repair was achieved in 34 of 43 (79%) patients. The remaining nine were terminated in favor of an open repair. The causes of failure were problems with access (2), balloon malfunction (1), stent dislodgment (3), graft thrombosis (1), and inability to deploy the contralateral limb of a bifurcated graft (2). All failed endoluminal repairs proceeded to successful open repair. There was no perioperative mortality in patients undergoing endoluminal repair or in those whose endoluminal repair was converted to open operation. Conclusions: The failures of endoluminal grafting have been analyzed. Methods of avoiding access problems, balloon malfunction, and stent dislodgment have been defined and recommendations made.

1 November 1995 in Journal of Endovascular Surgery
Verified
Journal Article
Closed access
TMTimothy J. McGahan
Timothy J. McGahan
GBGerald A. Berry
Gerald A. Berry
SMSarah L. McGahan
Sarah L. McGahan
GWGeoffrey H. White
Geoffrey H. White
WYWeiyun Yu
Weiyun Yu
JMJames May
James May
The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery ) was established in 1994 as a forum for all physicians, scientists, and al...

20 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
PPPhani Kumari Paritala
Phani Kumari Paritala
JMJessica Benitez Mendieta
Jessica Benitez Mendieta
YuanTong GuYuanTong Gu
YuanTong Gu
OROwen Christopher Raffel
Owen Christopher Raffel
ZLZhiyong Li
Zhiyong Li
A patient-specific carotid bifurcation with tandem stenosis found at both internal carotid artery (ICA) and common carotid artery (CCA) was studied. The in vivo pre-carotid endarterectomy (pre-CEA) multi-spectral magnetic resonance imaging (MRI) were performed and in vitro post-CEA carotid plaque tissue sample was collected. MR imaging data and tissue sample staining histology were used to recognize the plaque components. Further, the computational fluid dynamics (CFD) were performed on four MR-based reconstructed 3D carotid bifurcation models (the patient-specific geometry with tandem stenosis and three presumptive geometries by removing the stenosis part). The flow and shear stress behavior affected by the tandem stenosis was analyzed. From the results of MR segmentation and histology analysis, plaque lipid pool and calcification were found at both ICA and CCA. From the result of CFD simulation, the flow shear stress behavior suggested the tandem stenosis as a more “dangerous” situation than a single-stenosis artery. Besides, the CFD results deduced that the stenosis at the CCA location formed initially and led to the subsequent formation of stenosis at ICA. This study suggests that when planning CEA, CFD simulation on the presumptive models could help clinicians to estimate the blood flow behavior after surgery. Particular attention should be paid to the case of tandem stenosis, as the local hemodynamic environment is more complex and treatment of one stenosis may lead to a variation in the hemodynamic loading on the second plaque, which may result in either a higher risk of plaque rupture or restenosis.

31 August 1995 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
PDF file
JMJames May
James May
GWGeoffrey White
Geoffrey White
WYWeiyun Yu
Weiyun Yu
TSToos Sachinwalla
Toos Sachinwalla
TMTimothy McGahan
Timothy McGahan
GMGregory Monaghan
Gregory Monaghan