12 July 2023 in IEEE Transactions on Nuclear Science
Two compact generators of 14 MeV and 2.5 MeV neutrons have been installed in the new NILE facility. Neutrons are produced by Deuterium-Deuterium and Deuterium-Tritium fusion reactions. The facility has been designed with the assistance of Monte Carlo calculations. Here we present neutron measurements with multiple techniques for the characterization of the radiation field and dosimetry. Activation foils are used as a standard technique for passive measurements of neutron fluxes. Active detectors, like fission chambers, are used mainly as online neutron monitor. Diamond detectors are applied with the main purpose of high-resolution neutron spectroscopy. Scintillators are used as neutron monitors and spectrometers with the additional capability of neutron/gamma discrimination. The characterised neutron beams will be mainly applied for testing of electronics.
1 August 2024 in Review of Scientific Instruments
A new 14 MeV neutron spectrometer utilizing the magnetic proton recoil (MPR) technique is under development for the SPARC tokamak. This instrument measures neutrons by converting them into protons, whose momenta are subsequently analyzed using a series of magnets before detection by an array of scintillators known as the hodoscope. In this work, we explore various solutions for the hodoscope detectors through laboratory tests with radioactive sources and simulations. We present findings on light collection and pulse shape discrimination based on detector types, as well as optimal solutions for photo-detectors studying the differences between SiPM and PMT. Our results also led to the determination of a better optimized design for the hodoscope detectors, consisting of a 0.7 cm width and a 13 cm length EJ276D scintillation rod.
1 April 2026 in Journal of Instrumentation
The JET tangential gamma ray diagnostic had several key functions, mainly alpha particle detection, runaway electron monitor and recently fusion power estimation. All these measurements are affected by a common background, which can complicate signal detection and whose origin is not yet fully understood. A method to simulate such a background has previously been proposed, however it does not address the spatial origin of the background nor the isotopes responsible for its generation. In this work, we combine simulation tools, including MCNP, with analytical codes to better understand the sources of the background measured with the JET tangential gamma ray diagnostic. The role of the gamma ray flux produced in the tokamak central column is analysed in detail and its correlation with the detected gamma ray background is found.
16 April 2026 in IEEE Transactions on Plasma Science
A new method for measuring fusion power in DT plasmas using high-energy gamma spectroscopy was recently demonstrated at JET. Besides a $10^{5}$ times more intense background at lower energies, a gamma background in the signal energy region was observed but not identified, contributing to higher uncertainty on the measurements. Due to the rarity of the event considered and the complex geometry of the tokamak, a new method to simulate the gamma background at high energy using MCNP was required. In this work, a combination of variance reduction techniques was developed by analyzing the nature of the background and validated by comparing simulation results to experimental data. The library comparison showed that ENDF/B-VIII is the library that better describes the shape of the high-energy gamma background, although the simulated component is 2.5 times higher than experimental data. Results using Fendl 3.1d nuclear library presented reduced discrepancy in magnitude, albeit with a distinct spectral distribution.
1 November 2026 in Review of Scientific Instruments
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
5 November 2026 in Fusion Engineering and Design