30 July 2024 in Physical Review Letters
At present, magnetic confinement fusion devices rely solely on absolute neutron counting as a direct way of measuring fusion power. Absolute counting of deuterium-tritium gamma rays could provide the secondary neutron-independent technique required for the validation of scientific results and as a licensing tool for future power plants. However, this approach necessitates an accurate determination of the gamma-ray-to-neutron branching ratio. The gamma-ray-to-neutron branching ratio for the deuterium-tritium reaction was determined in magnetic confinement fusion plasmas at the Joint European Torus in predominantly deuterium beam heated plasmas. The branching ratio was found to be equal to over the deuterium energy range of . This accurate determination of the deuterium-tritium branching ratio paves the way for a direct and neutron-independent measurement of fusion power in magnetic confinement fusion reactors, based on the absolute counting of deuterium-tritium gamma rays.
1 October 2024 in Review of Scientific Instruments
Neutron measurement is the primary tool in the SPARC tokamak for fusion power (Pfus) monitoring, research on the physics of burning plasmas, validation of the neutronics simulation workflows, and providing feedback for machine protection. A demanding target uncertainty (10% for Pfus) and coverage of a wide dynamic range (>8 orders of magnitude going up to 5 × 1019 n/s), coupled with a fast-track timeline for design and deployment, make the development of the SPARC neutron diagnostics challenging. Four subsystems are under design that exploit the high flux of direct DT and DD plasma neutrons emanating from a shielded opening in a midplane diagnostic port. The systems comprise a set of ∼15 flux monitors, mainly ionization chambers and proportional counters for measurement of the neutron yield rate, two independent foil activation systems for measurement of the neutron fluence, a spectrometric radial neutron camera for poloidal profiling of the plasma emissivity, and a high-resolution magnetic proton recoil spectrometer for measurement of the core neutron spectrum. Together, the four systems ensure redundancy of sensors and methods and aim to provide high resolutions of time (10 ms), space (∼7 cm), and energy (<2% at 14 MeV). This paper presents the broader objectives behind the preliminary design of the SPARC neutron diagnostics and discusses the ongoing studies on neutronics, detector comparisons, prototyping, and integration with the unique infrastructure of SPARC. Engineering details of the four subsystems and the concepts for in situ neutron calibration are also highlighted.
1 October 2024 in Review of Scientific Instruments
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
1 October 2024 in Review of Scientific Instruments
A magnetic proton recoil (MPR) neutron spectrometer is being designed for SPARC, a high magnetic field (BT = 12 T), compact (R0 = 1.85 m, a = 0.57 m) tokamak currently under construction in Devens, MA, USA. MPR neutron spectrometers are versatile tools for making high fidelity ab initio calibrated measurements of fusion neutron flux spectra and have been used to infer fusion power, ion temperature, fuel ion ratio, and suprathermal fuel populations at several high performance fusion experiments. The performance of an MPR neutron spectrometer is in large part determined by the design of the magnetic field, which disperses and focuses recoil protons. This article details the ion optical design of a high-resolution MPR neutron spectrometer, including the amelioration of image aberrations due to nonlinear effects. An optimized design is presented that achieves ion optical energy resolution δE/E < 1% and focal plane properties that enable straightforward integration with the hodoscope detector array.
1 August 2024 in Review of Scientific Instruments
A new 14 MeV neutron spectrometer utilizing the magnetic proton recoil (MPR) technique is under development for the SPARC tokamak. This instrument measures neutrons by converting them into protons, whose momenta are subsequently analyzed using a series of magnets before detection by an array of scintillators known as the hodoscope. In this work, we explore various solutions for the hodoscope detectors through laboratory tests with radioactive sources and simulations. We present findings on light collection and pulse shape discrimination based on detector types, as well as optimal solutions for photo-detectors studying the differences between SiPM and PMT. Our results also led to the determination of a better optimized design for the hodoscope detectors, consisting of a 0.7 cm width and a 13 cm length EJ276D scintillation rod.
24 July 2025 in Nuclear Fusion
The Joint European Torus performed its second deuterium–tritium (DT) campaign at the end of 2021. This unique opportunity was exploited to carry out the first absolute measurement in a magnetic confinement plasma of the total gamma-ray emission from the DT fusion reaction, namely the less probable (branching ratio ) electromagnetic counterpart of the main neutronic decay channel. A single line of sight gamma-ray spectrometer was employed for this purpose. Numerous challenges had to be addressed in order to pursue the goal: (1) characterise the detector beamline and its detection efficiency in absolute terms, (2) dealing with an extended and non-uniform source, (3) suppress the intense neutron background, (4) handle the high event rate at the detector and (5) discriminate between signal and background in the acquired energy spectrum. This paper describes the procedure adopted for measuring the total DT gamma-ray yield of 96 DT plasma discharges with event rates below hundred kHz. The results were validated through a comparison with the neutron yields provided by the Joint European Torus neutron monitors, revealing an outstanding 0.983 linear correlation. This work proves the feasibility to employ the gamma-ray emission of the DT fusion reaction as a secondary indicator for measuring the fusion power in magnetically confined DT plasmas.