Lauri Parkkonen

Lauri Parkkonen

Auto-generated profile, based on publicly available information

Lauri Parkkonen

Aalto University

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in NeuroImage
Verified
Journal Article
Closed access
AGAlexandre Gramfort
Alexandre Gramfort
MLMartin Luessi
Martin Luessi
ELEric Larson
Eric Larson
DEDenis-Alexander Engemann
Denis-Alexander Engemann
DSDaniel Strohmeier
Daniel Strohmeier
MHMatti S. Hämäläinen
Matti S. Hämäläinen

1 January 2013 in NeuroImage
Verified
Journal Article
Open access
JGJoachim Gross
Joachim Gross
SBSylvain Baillet
Sylvain Baillet
GBGareth Barnes
Gareth Barnes
RHRichard N Henson
Richard N Henson
AHArjan Hillebrand
Arjan Hillebrand
JSJan-Mathijs Schoffelen
Jan-Mathijs Schoffelen
Magnetoencephalographic (MEG) recordings are a rich source of information about the neural dynamics underlying cognitive processes in the brain, with excellent temporal and good spatial resolution. In recent years there have been considerable advances in MEG hardware developments and methods. Sophisticated analysis techniques are now routinely applied and continuously improved, leading to fascinating insights into the intricate dynamics of neural processes. However, the rapidly increasing level of complexity of the different steps in a MEG study make it difficult for novices, and sometimes even for experts, to stay aware of possible limitations and caveats. Furthermore, the complexity of MEG data acquisition and data analysis requires special attention when describing MEG studies in publications, in order to facilitate interpretation and reproduction of the results. This manuscript aims at making recommendations for a number of important data acquisition and data analysis steps and suggests details that should be specified in manuscripts reporting MEG studies. These recommendations will hopefully serve as guidelines that help to strengthen the position of the MEG research community within the field of neuroscience, and may foster discussion in order to further enhance the quality and impact of MEG research.

1 October 2015 in Neuron
Verified
Journal Article
Closed access
RHRiitta Hari
Riitta Hari
LHLinda Henriksson
Linda Henriksson
SMSanna Malinen
Sanna Malinen
LPLauri Parkkonen
Lauri Parkkonen

1 February 2017 in NeuroImage
Verified
Journal Article
Open access
Joonas IivanainenJoonas Iivanainen
Joonas Iivanainen
MSMatti Stenroos
Matti Stenroos
LPLauri Parkkonen
Lauri Parkkonen
Optically-pumped magnetometers (OPMs) have recently reached sensitivity levels required for magnetoencephalography (MEG). OPMs do not need cryogenics and can thus be placed within millimetres from the scalp into an array that adapts to the individual head size and shape, thereby reducing the distance from cortical sources to the sensors. Here, we quantified the improvement in recording MEG with hypothetical on-scalp OPM arrays compared to a 306-channel state-of-the-art SQUID array (102 magnetometers and 204 planar gradiometers). We simulated OPM arrays that measured either normal (nOPM; 102 sensors), tangential (tOPM; 204 sensors), or all components (aOPM; 306 sensors) of the magnetic field. We built forward models based on magnetic resonance images of 10 adult heads; we employed a three-compartment boundary element model and distributed current dipoles evenly across the cortical mantle. Compared to the SQUID magnetometers, nOPM and tOPM yielded 7.5 and 5.3 times higher signal power, while the correlations between the field patterns of source dipoles were reduced by factors of 2.8 and 3.6, respectively. Values of the field-pattern correlations were similar across nOPM, tOPM and SQUID gradiometers. Volume currents reduced the signals of primary currents on average by 10%, 72% and 15% in nOPM, tOPM and SQUID magnetometers, respectively. The information capacities of the OPM arrays were clearly higher than that of the SQUID array. The dipole-localization accuracies of the arrays were similar while the minimum-norm-based point-spread functions were on average 2.4 and 2.5 times more spread for the SQUID array compared to nOPM and tOPM arrays, respectively.

1 January 1993 in Physica Scripta
Verified
Journal Article
Closed access
AAA I Ahonen
A I Ahonen
MHM S Hämäläinen
M S Hämäläinen
MKM J Kajola
M J Kajola
JKJ E T Knuutila
J E T Knuutila
PLP P Laine
P P Laine
CTC D Tesche
C D Tesche

1 July 2019 in NeuroImage
Verified
Journal Article
Open access
Joonas IivanainenJoonas Iivanainen
Joonas Iivanainen
RZRasmus Zetter
Rasmus Zetter
MGMikael Grön
Mikael Grön
KHKaroliina Hakkarainen
Karoliina Hakkarainen
LPLauri Parkkonen
Lauri Parkkonen
The spatial resolution of magnetoencephalography (MEG) can be increased from that of conventional SQUID-based systems by employing on-scalp sensor arrays of e.g. optically-pumped magnetometers (OPMs). However, OPMs reach sufficient sensitivity for neuromagnetic measurements only when operated in a very low absolute magnetic field of few nanoteslas or less, usually not reached in a typical magnetically shielded room constructed for SQUID-based MEG. Moreover, field drifts affect the calibration of OPMs. Static and dynamic suppression of interfering fields is thus necessary for good-quality neuromagnetic measurements with OPMs. Here, we describe an on-scalp MEG system that utilizes OPMs and external compensation coils that provide static and dynamic shielding against ambient fields. In a conventional two-layer magnetically shielded room, our coil system reduced the maximum remanent DC-field component within an 8-channel OPM array from 70 to less than 1 nT, enabling the sensors to operate in the sensitive spin exchange relaxation-free regime. When compensating field drifts below 4 Hz, a low-frequency shielding factor of 22 dB was achieved, which reduced the peak-to-peak drift from 1.3 to 0.4 nT and thereby the standard deviation of the sensor calibration from 1.7% to 0.5%. Without band-limiting the field that was compensated, a low-frequency shielding factor of 43 dB was achieved. We validated the system by measuring brain responses to electric stimulation of the median nerve. With dynamic shielding and digital interference suppression methods, single-trial somatosensory evoked responses could be detected. Our results advance the deployment of OPM-based on-scalp MEG in lighter magnetic shields.