12 September 2023 in IEEE Transactions on Power Delivery
A damping-controllable-commutated converter (DCCC) is proposed to enhance the commutation failure (CF) mitigation capability of line-commutated converter-based high-voltage direct current (LCC-HVDC) systems. The DCCC comprises a main branch and an auxiliary branch, with the main branch consisting of thyristors and a few high-current capacity integrated gate-commutated thyristors ( i -IGCTs) and the auxiliary branch composed of damping modules and a few high-voltage tolerance IGCTs ( v -IGCTs). In normal operating conditions, the DCCC operates like the LCC for commutation. However, under fault conditions, the commutation process in the DCCC is decomposed into a current-limiting process and a forced commutation process. During the current-limiting process, the damping module transfers the valve current to the auxiliary branch, and the i -IGCTs actively block the main branch in the zero-current state. When the current reaches the turn-off value of the v -IGCTs, the forced commutation process is initiated, and the v -IGCTs actively turn off the current to complete the commutation. Operation strategy for DCCC and parameters for damping and snubber circuits are devised based on the preceding work modes. Simulations show that the DCCC can effectively enhance the CF mitigation capacity of the system, with the switching device maintaining reasonable electrical stress.
6 January 2022 in IEEE Transactions on Power Delivery
With the emergence of the hybrid multi-infeed high voltage direct current (HMIDC) system, there is complex dynamic interaction between the AC/DC system and converter stations, while the interaction mechanism of the HMIDC system is unclear. For this purpose, this paper establishes the HMIDC linearized model based on the motion equation concept. Then, after decoupling and reconstructing the interaction path of the HMIDC system, the damping coefficients are derived. The AC system strength and voltage source converter (VSC) terminal voltage controller parameters are selected to analyze the impacts on damping coefficients, and the interaction mechanism of the HMIDC system is analyzed. In order to solve the potential instability issue, an additional damping controller in the VSC terminal voltage loop is proposed to enhance the voltage stability of HMIDC system, which is realized by adjusting the reactive power/amplitude coupling damping coefficient. Finally, the RT-LAB-based hardware-in-the-loop experiments verify the accuracy of the interaction mechanism analysis of the HMIDC system and the effectiveness of the proposed controller.
27 April 2022 in IEEE Transactions on Power Delivery
In actual line-commutated converter based high- voltage direct-current (LCC-HVDC) projects, multiple HVDC transmission lines are usually installed on the same tower to save transmission corridors and reduce construction costs. However, electromagnetic coupling effect between adjacent lines can cause commutation failure (CF) in the non-fault poles when a line or pole fails. Hence, this paper deeply investigates the mechanism and the prevention strategy of CFs caused by line coupling effect in single- and double-circuit HVDC systems. The influencing factors of line coupling effect and the coupling characteristics under fault conditions are analyzed first based on the modeling of parallel transmission lines and the traveling wave theory. Then the mechanism of CF caused by line coupling effect is investigated with the consideration of different fault conditions, different line structures, and different system operation modes. Based on the above analyses, prevention strategies for CFs of non-fault poles in single- and double-circuit systems are proposed, respectively. Finally, the simulation results verify the correctness of the theoretical analyses and the effectiveness of the proposed control strategies.