Yifeng Liu

Yifeng Liu

Auto-generated profile, based on publicly available information

Yifeng Liu

College of Electrical and Information Engineering, Hunan University, Changsha, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLerong Hong
Lerong Hong
XZXiaoping Zhou
Xiaoping Zhou
HXHaitao Xia
Haitao Xia
YLYifeng Liu
Yifeng Liu
ALAn Luo
An Luo

19 August 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLerong Hong
Lerong Hong
XZXiaoping Zhou
Xiaoping Zhou
YLYifeng Liu
Yifeng Liu
HXHaitao Xia
Haitao Xia
HYHanhang Yin
Hanhang Yin
QXQianming Xu
Qianming Xu
In a line-commutated converter based high-voltage direct-current (LCC-HVDC) system, the inverter control system usually includes constant extinction angle (CEA) controller, constant current (CC) controller, current error controller (CEC), and voltage-dependent current order limiter (VDCOL). However, the interaction influence of multiple controllers may cause repetitive commutation failure (CF). For this purpose, this paper deeply investigates the mechanism and the influencing factors of repetitive CF caused by controller interaction. It is found that the lower limit value of CEA controller can affect the control switching process and thus the probability of repetitive CF. Besides, the minimum gamma measurement (MGM) unit prevents the system from acquiring the real extinction angle in time, which results in the DC current fluctuation during the recovery process. Moreover, the probability of control-induced repetitive CF is much higher when the HVDC inverter is connected to a weak AC system or the AC fault is not serious but not cleared in time. Based on the above analyses, an improved control method is proposed for recovery performance improvement, which is mainly realized by modifying the lower and upper limits of the CEA controller during recovery. Finally, the simulation and experimental results verify the theoretical analyses and the proposed control method.

17 April 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YLYifeng Liu
Yifeng Liu
XZXiaoping Zhou
Xiaoping Zhou
HYHaoqi Yu
Haoqi Yu
LHLerong Hong
Lerong Hong
HXHaitao Xia
Haitao Xia
WWWenhua Wu
Wenhua Wu
Load converter operating in the weak grid potentially suffers harmonic oscillation problem due to the impedance interaction. In this paper, considering DC-link voltage dynamics and frequency-coupling effects, the precise sequence impedance models are derived for the traditional load converter (TLC) and the load virtual synchronous machine (LVSM). Based on the derived models, their sequence impedance characteristics are analyzed and compared. The analysis shows that the positive-sequence impedance of the LVSM is generally inductive in the middle- and low-frequency bands, which is basically consistent with the grid impedance characteristics. In contrast, the positive-sequence impedance of the TLC is negative-resistive-capacitive (i.e., phase angle is between -180° and -90°) in the middle- and low-frequency bands, and its amplitude-frequency curve is easy to intersect with the amplitude-frequency curve of the grid impedance, which may lead to harmonic oscillation in the weak grid. Furthermore, based on the derived model and Nyquist stability criterion, the effects of the grid impedance and load power on the stability are analyzed for TLC and LVSM, which indicates that the LVSM has better stability in the weak grid than the TLC. Finally, the experimental results validate the correctness of the theoretical analyses.

6 January 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YHYin Hanhang
Yin Hanhang
XZXiaoping Zhou
Xiaoping Zhou
YLYifeng Liu
Yifeng Liu
HXHaitao Xia
Haitao Xia
LHLerong Hong
Lerong Hong
LDLingfeng Deng
Lingfeng Deng
With the emergence of the hybrid multi-infeed high voltage direct current (HMIDC) system, there is complex dynamic interaction between the AC/DC system and converter stations, while the interaction mechanism of the HMIDC system is unclear. For this purpose, this paper establishes the HMIDC linearized model based on the motion equation concept. Then, after decoupling and reconstructing the interaction path of the HMIDC system, the damping coefficients are derived. The AC system strength and voltage source converter (VSC) terminal voltage controller parameters are selected to analyze the impacts on damping coefficients, and the interaction mechanism of the HMIDC system is analyzed. In order to solve the potential instability issue, an additional damping controller in the VSC terminal voltage loop is proposed to enhance the voltage stability of HMIDC system, which is realized by adjusting the reactive power/amplitude coupling damping coefficient. Finally, the RT-LAB-based hardware-in-the-loop experiments verify the accuracy of the interaction mechanism analysis of the HMIDC system and the effectiveness of the proposed controller.

19 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYifeng Liu
Yifeng Liu
XZXiaoping Zhou
Xiaoping Zhou
YCYandong Chen
Yandong Chen
LZLeming Zhou
Leming Zhou
LWLei Wang
Lei Wang
WWWenhua Wu
Wenhua Wu
Load converters with inertial support are used to enhance the system inertia. However, these converters may fail to operate stably in the weak grid. In this paper, sequence impedance modeling and stability comparison analysis are proposed for the load virtual synchronous machine (LVSM) and the load converter with virtual inertia control (LCVIC). Firstly, the universal sequence impedance formulas are derived by considering dc-link voltage dynamics and frequency-coupling effects. Then, the precise sequence impedance models are built for impedance characteristics analysis of LVSM and LCVIC. The analysis shows that the positive-sequence impedance of LVSM is generally inductive in the middle-frequency band, which is basically consistent with the grid impedance. In contrast, the positive-sequence impedance of LCVIC is negative-resistive-capacitive (i.e., phase angle is between -180° and -90°) in the middle-frequency band, which may lead to harmonic oscillation in the weak grid. Furthermore, the effects of grid impedance, load power, and other control parameters on the stability are analyzed for the two load converters based on the derived model and Nyquist stability criterion. The analysis results reveal that LVSM has better stability than LCVIC in the weak grid. Finally, the experimental results validate the correctness of the theoretical analyses.

27 April 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLerong Hong
Lerong Hong
XZXiaoping Zhou
Xiaoping Zhou
HXHaitao Xia
Haitao Xia
YLYifeng Liu
Yifeng Liu
RZRenlong Zhu
Renlong Zhu
YCYandong Chen
Yandong Chen
In actual line-commutated converter based high- voltage direct-current (LCC-HVDC) projects, multiple HVDC transmission lines are usually installed on the same tower to save transmission corridors and reduce construction costs. However, electromagnetic coupling effect between adjacent lines can cause commutation failure (CF) in the non-fault poles when a line or pole fails. Hence, this paper deeply investigates the mechanism and the prevention strategy of CFs caused by line coupling effect in single- and double-circuit HVDC systems. The influencing factors of line coupling effect and the coupling characteristics under fault conditions are analyzed first based on the modeling of parallel transmission lines and the traveling wave theory. Then the mechanism of CF caused by line coupling effect is investigated with the consideration of different fault conditions, different line structures, and different system operation modes. Based on the above analyses, prevention strategies for CFs of non-fault poles in single- and double-circuit systems are proposed, respectively. Finally, the simulation results verify the correctness of the theoretical analyses and the effectiveness of the proposed control strategies.