Jose Yeste

Jose Yeste

Auto-generated profile, based on publicly available information

Jose Yeste

Institute for Bioengineering of Catalonia, The Barcelona Institute of Science and Technology, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2018 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
JYJose Yeste
Jose Yeste
XIXavi Illa
Xavi Illa
Mar AlvarezMar Alvarez
Mar Alvarez
RSRosa Villa Sanz
Rosa Villa Sanz
Epithelia and endothelia delineate tissue compartments and control their environments by regulating the passage of ions and solutes. This barrier function is essential for the development and maintenance of multicellular organisms, and its dysfunction is associated with numerous human diseases. Recent advances in biomaterials and microfabrication technologies have evolved in vitro approaches for modelling biological barriers. Current microphysiological systems have become more efficient and reliable in mimicking the cell microenvironment. Additionally, methods for the quantification of barrier permeability have long provided significant insight into their underlying mechanisms. In this review, we outline the current techniques to quantify the barrier function of engineered tissues, and we also give an overview of recent microphysiological systems of biological barriers that emulate the microenvironment and microarchitecture of native tissues.

14 November 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JYJose Yeste
Jose Yeste
MGMarta García-Ramírez
Marta García-Ramírez
XIXavi Illa
Xavi Illa
ABAnton Guimerà Brunet
Anton Guimerà Brunet
CHCristina Hernández
Cristina Hernández
RSRosa Villa Sanz
Rosa Villa Sanz
The interconnection of different tissue–tissue interfaces may extend organ-on-chips to a new generation of sophisticated models capable of recapitulating more complex organ-level functions. Single interfaces are largely recreated in organ-on-chips by culturing the cells on opposite sides of a porous membrane that splits a chamber in two or by connecting the cells of two adjacent compartments through microchannels. However, it is difficult to interconnect more than one interface using these approaches. To address this challenge, we present a novel microfluidic device where cells are arranged in parallel compartments and are highly interconnected through a grid of microgrooves, which facilitates paracrine signaling and heterotypic cell–cell contact between multiple tissues. In addition, the device includes electrodes on the substrate for the measurement of transepithelial electrical resistance (TEER). Unlike conventional methods for measuring the TEER where electrodes are on each side of the cell barrier, a method with only electrodes on the substrate has been validated. As a proof-of-concept, we have used the device to mimic the structure of the blood–retinal barrier by co-culturing primary human retinal endothelial cells (HREC), a human neuroblastoma cell line (SH-SY5Y), and a human retinal pigment epithelial cell line (ARPE-19). Cell barrier formations were assessed by a permeability assay, TEER measurements, and ZO-1 expression. These results validate the proposed microfluidic device with microgrooves as a promising in vitro tool for the compartmentalization and monitoring of barrier tissues.

18 August 2016 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
JYJ Yeste
J Yeste
XIXavi Illa
Xavi Illa
CGC Gutiérrez
C Gutiérrez
Montse SoléMontse Solé
Montse Solé
ABAnton Guimerà Brunet
Anton Guimerà Brunet
RSRosa Villa Sanz
Rosa Villa Sanz
Transepithelial electrical resistance (TEER) measurements are regularly used in in vitro models to quantitatively evaluate the cell barrier function. Although it would be expected that TEER values obtained with the same cell type and experimental setup were comparable, values reported in the literature show a large dispersion for unclear reasons. This work highlights a possible error in a widely used formula to calculate the TEER, in which it may be erroneously assumed that the entire cell culture area contributes equally to the measurement. In this study, we have numerically calculated this error in some cell cultures previously reported. In particular, we evidence that some TEER measurements resulted in errors when measuring low TEERs, especially when using Transwell inserts 12 mm in diameter or microfluidic systems that have small chamber heights. To correct this error, we propose the use of a geometric correction factor (GCF) for calculating the TEER. In addition, we describe a simple method to determine the GCF of a particular measurement system, so that it can be applied retrospectively. We have also experimentally validated an interdigitated electrodes (IDE) configuration where the entire cell culture area contributes equally to the measurement, and it also implements minimal electrode coverage so that the cells can be visualized alongside TEER analysis.

30 June 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
NSNitesh Shashikanth
Nitesh Shashikanth
MFMarion M. France
Marion M. France
RXRuyue Xiao
Ruyue Xiao
XHXenia Haest
Xenia Haest
HRHeather E. Rizzo
Heather E. Rizzo
JTJerrold Turner
Jerrold Turner
Tight junctions form selectively permeable seals across the paracellular space. Both barrier function and selective permeability have been attributed to members of the claudin protein family, which can be categorized as pore-forming or barrier-forming. Here, we show that claudin-4, a prototypic barrier-forming claudin, reduces paracellular permeability by a previously unrecognized mechanism. Claudin-4 knockout or overexpression has minimal effects on tight junction permeability in the absence of pore-forming claudins. However, claudin-4 selectively inhibits flux across cation channels formed by claudins 2 or 15. Claudin-4-induced loss of claudin channel function is accompanied by reduced anchoring and subsequent endocytosis of pore-forming claudins. Analyses in nonepithelial cells show that claudin-4, which is incapable of independent polymerization, disrupts polymeric strands and higher order meshworks formed by claudins 2, 7, 15, and 19. This process of interclaudin interference, in which one claudin disrupts higher order structures and channels formed by a different claudin, represents a previously unrecognized mechanism of barrier regulation.

1 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Pedro EscuderoPedro Escudero
Pedro Escudero
JYJ. Yeste
J. Yeste
CPC. Pascual-Izarra
C. Pascual-Izarra
RSRosa Villa Sanz
Rosa Villa Sanz
Mar AlvarezMar Alvarez
Mar Alvarez
We demonstrate an integrated optical pressure sensing platform for multiplexed optofluidics applications. The sensing platform consists in an array of elastomeric on-side nanostructured membranes -effectively 2D photonic crystal- which present colour shifts in response to mechanical stress that alter their nanostructure characteristical dimensions, pitch or orientation. The photonic membranes are prepared by a simple and cost-effective method based on the infiltration of a 2D colloidal photonic crystal (CPC) with PDMS and their integration with a microfluidic system. We explore the changes in the white light diffraction produced by the nanostructured membranes when varying the pneumatic pressure in the microfluidics channels as a way to achieve a power-free array of pressure sensors that change their reflective colour depending on the bending produced on each sensor. The structural characterization of these membranes was performed by SEM, while the optical properties and the pressure-colour relation were evaluated via UV-Vis reflection spectrometry. Maximum sensitivities of 0.17 kPa−1 is obtained when measuring at Littrow configuration (θin = −θout), and close to the border of the membranes. The reflected colour change with pressure is as well monitorized by using a smartphone camera.

6 November 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XIXavi Illa
Xavi Illa
SVSergi Vila
Sergi Vila
JYJose Yeste
Jose Yeste
Carmen PeraltaCarmen Peralta
Carmen Peralta
Jordi Gracia-SanchoJordi Gracia-Sancho
Jordi Gracia-Sancho
RSRosa Villa Sanz
Rosa Villa Sanz
We describe a unique, versatile bioreactor consisting of two plates and a modified commercial porous membrane suitable for in vitro analysis of the liver sinusoid. The modular bioreactor allows i) excellent control of the cell seeding process; ii) cell culture under controlled shear stress stimulus, and; iii) individual analysis of each cell type upon completion of the experiment. The advantages of the bioreactor detailed here are derived from the modification of a commercial porous membrane with an elastomeric wall specifically moulded in order to define the cell culture area, to act as a gasket that will fit into the bioreactor, and to provide improved mechanical robustness. The device presented herein has been designed to simulate the in vivo organization of a liver sinusoid and tested by co-culturing endothelial cells (EC) and hepatic stellate cells (HSC). The results show both an optimal morphology of the endothelial cells as well as an improvement in the phenotype of stellate cells, most probably due to paracrine factors released from endothelial cells. This device is proposed as a versatile, easy-to-use co-culture system that can be applied to biomedical research of vascular systems, including the liver.