Kristin Castorino

Sansum Diabetes Research Institute, Santa Barbara, CA, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2020 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
KCKristin Castorino
Kristin Castorino
SPSarit Polsky
Sarit Polsky
GOGrenye O'MAlley
Grenye O'MAlley
CLCamilla Levister
Camilla Levister
KNKristen Nelson
Kristen Nelson
CLCarol J. Levy
Carol J. Levy
Background: The aim of this study was to determine the performance of the Dexcom G6 continuous glucose monitoring (CGM) system across three sensor wear sites in pregnant women with diabetes in the second or third trimesters. Methods: Participants with type 1 (T1D), type 2 (T2D), or gestational (GDM) diabetes mellitus were enrolled at three sites. Each wore two G6 sensors on the abdomen, upper buttock, and/or posterior upper arm for 10 days and underwent a 6-h clinic session between days 3 and 7 of sensor wear, during which YSI reference blood glucose values were obtained every 30 min. No intentional glucose manipulations were performed. Accuracy metrics included the proportion of CGM values that were within ±20% of paired reference values >100 mg/dL or ±20 mg/dL of YSI values ≤100 mg/dL (hereafter referred to as %20/20), as well as the analogous %15/15, %30/30, and %40/40. The mean absolute relative difference (MARD) between CGM-YSI pairs was also calculated. Results: Thirty-two participants with T1D ( n = 20), T2D ( n = 3), or GDM ( n = 9) were enrolled: 19 were in the second trimester and 13 were in the third trimester of pregnancy. Compared with the reference, 92.5% of CGM values were within ±20%/20 mg/dL. The overall MARD and that of sensors worn on the abdomen, upper buttock, and posterior upper arm was 10.3%, 11.5%, 11.2%, and 8.7%, respectively. There were no device-related adverse events. Skin reactions at the insertion sites were absent or minor. Conclusions: The Dexcom G6 CGM system is accurate and safe in pregnant women with diabetes.

4 October 2021 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
PDF file
KNKevin T. Nguyen
Kevin T. Nguyen
NXNicole Y. Xu
Nicole Y. Xu
JZJennifer Y. Zhang
Jennifer Y. Zhang
TSTrisha Shang
Trisha Shang
ABAnanda Basu
Ananda Basu
DKDavid C. Klonoff
David C. Klonoff
This article is the work product of the Continuous Ketone Monitoring Consensus Panel, which was organized by Diabetes Technology Society and met virtually on April 20, 2021. The panel consisted of 20 US-based experts in the use of diabetes technology, representing adult endocrinology, pediatric endocrinology, advanced practice nursing, diabetes care and education, clinical chemistry, and bioengineering. The panelists were from universities, hospitals, freestanding research institutes, government, and private practice. Panelists reviewed the medical literature pertaining to ten topics: (1) physiology of ketone production, (2) measurement of ketones, (3) performance of the first continuous ketone monitor (CKM) reported to be used in human trials, (4) demographics and epidemiology of diabetic ketoacidosis (DKA), (5) atypical hyperketonemia, (6) prevention of DKA, (7) non-DKA states of fasting ketonemia and ketonuria, (8) potential integration of CKMs with pumps and automated insulin delivery systems to prevent DKA, (9) clinical trials of CKMs, and (10) the future of CKMs. The panelists summarized the medical literature for each of the ten topics in this report. They also developed 30 conclusions (amounting to three conclusions for each topic) about CKMs and voted unanimously to adopt the 30 conclusions. This report is intended to support the development of safe and effective continuous ketone monitoring and to apply this technology in ways that will benefit people with diabetes.

16 February 2023 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
JHJingtong Huang
Jingtong Huang
AYAndrea M. Yeung
Andrea M. Yeung
RBRichard M. Bergenstal
Richard M. Bergenstal
KCKristin Castorino
Kristin Castorino
ECEda Cengiz
Eda Cengiz
DKDavid C. Klonoff
David C. Klonoff
Ketone bodies are an energy substrate produced by the liver and used during states of low carbohydrate availability, such as fasting or prolonged exercise. High ketone concentrations can be present with insulin insufficiency and are a key finding in diabetic ketoacidosis (DKA). During states of insulin deficiency, lipolysis increases and a flood of circulating free fatty acids is converted in the liver into ketone bodies—mainly beta-hydroxybutyrate and acetoacetate. During DKA, beta-hydroxybutyrate is the predominant ketone in blood. As DKA resolves, beta-hydroxybutyrate is oxidized to acetoacetate, which is the predominant ketone in the urine. Because of this lag, a urine ketone test might be increasing even as DKA is resolving. Point-of-care tests are available for self-testing of blood ketones and urine ketones through measurement of beta-hydroxybutyrate and acetoacetate and are cleared by the US Food and Drug Administration (FDA). Acetone forms through spontaneous decarboxylation of acetoacetate and can be measured in exhaled breath, but currently no device is FDA-cleared for this purpose. Recently, technology has been announced for measuring beta-hydroxybutyrate in interstitial fluid. Measurement of ketones can be helpful to assess compliance with low carbohydrate diets; assessment of acidosis associated with alcohol use, in conjunction with SGLT2 inhibitors and immune checkpoint inhibitor therapy, both of which can increase the risk of DKA; and to identify DKA due to insulin deficiency. This article reviews the challenges and shortcomings of ketone testing in diabetes treatment and summarizes emerging trends in the measurement of ketones in the blood, urine, breath, and interstitial fluid.

25 November 2021 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
GOGrenye O’Malley
Grenye O’Malley
BOBasak Ozaslan
Basak Ozaslan
CLCarol J. Levy
Carol J. Levy
KCKristin Castorino
Kristin Castorino
DDDonna Desjardins
Donna Desjardins
EDEyal Dassau
Eyal Dassau
Background: Suboptimal glycemic control is associated with maternal and neonatal morbidity and mortality in pregnancy complicated by type 1 diabetes (T1D). Prospective analysis of continuous glucose monitoring (CGM) metrics, insulin pump settings, and insulin delivery can better characterize the changes in glycemic levels and insulin use throughout pregnancy with T1D. Materials and Methods: Prescribed parameters, insulin delivery, carbohydrate intake, and CGM data for 25 pregnant women with T1D from three U.S. sites were collected. Participants enrolled before 17 weeks gestation and used personal insulin pumps and study CGM. Mean daily total, basal, and bolus insulin doses (units/kg), CGM time in range (TIR: 63–140 mg/dL), and pump-entered carbohydrates were analyzed for every 2-week gestational interval. Linear mixed-effects regression models were used to evaluate changes across gestational ages compared to 12–14 weeks. Results: Basal insulin was higher during weeks 6–12 and 24–40. Daily bolus and total insulin were higher during weeks 20–40. Pump parameters were adjusted to intensify insulin therapy from 22 weeks onward. Average TIR across pregnancy was 59% ± 14%. Between 18 and 30 weeks, TIR was significantly lower, and time above range was significantly higher compared to the reference biweek. Time below target was lower between 22 and 34 weeks. Seven participants achieved >70% recommended TIR for pregnancy. Participants with maternal complications or infant neonatal intensive care unit admissions had lower TIR. Conclusion: While insulin dosing changed significantly with advancing gestation, most participants did not achieve >70% TIR. Customized anticipatory pump setting adjustments and automated systems aimed toward the designated TIR are needed to improve outcomes for this population. NCT03761615

18 October 2024 in Diabetes Care
Verified
Journal Article
Open access
PDF file
EREric Renard
Eric Renard
RWRuth S Weinstock
Ruth S Weinstock
GAGrazia Aleppo
Grazia Aleppo
BBBruce W. Bode
Bruce W. Bode
SBSue A. Brown
Sue A. Brown
OGOP5-003 Research Group
OP5-003 Research Group
OBJECTIVE: To examine the efficacy and safety of the tubeless Omnipod 5 automated insulin delivery (AID) system compared with pump therapy with a continuous glucose monitor (CGM) in adults with type 1 diabetes with suboptimal glycemic outcomes. RESEARCH DESIGN AND METHODS: In this 13-week multicenter, parallel-group, randomized controlled trial performed in the U.S. and France, adults aged 18–70 years with type 1 diabetes and HbA1c 7–11% (53–97 mmol/mol) were randomly assigned (2:1) to intervention (tubeless AID) or control (pump therapy with CGM) following a 2-week standard therapy period. The primary outcome was a treatment group comparison of time in range (TIR) (70–180 mg/dL) during the trial period. RESULTS: A total of 194 participants were randomized, with 132 assigned to the intervention and 62 to the control. TIR during the trial was 4.2h/day higher in the intervention compared with the control group (mean difference 17.5% [95% CI 14.0%, 21.1%]; P < 0.0001). The intervention group had a greater reduction in HbA1c from baseline compared with the control group (mean ± SD −1.24 ± 0.75% [−13.6 ± 8.2 mmol/mol] vs. −0.68 ± 0.93% [−7.4 ± 10.2 mmol/mol], respectively; P < 0.0001), accompanied by a significantly lower time 180 mg/dL (37.6 ± 11.4% vs. 54.5 ± 15.4%; P < 0.0001). All primary and secondary outcomes were met. No instances of diabetes-related ketoacidosis or severe hypoglycemia occurred in the intervention group. CONCLUSIONS: Use of the tubeless AID system led to improved glycemic outcomes compared with pump therapy with CGM among adults with type 1 diabetes, underscoring the clinical benefit of AID and bolstering recommendations to establish AID systems as preferred therapy for this population.

23 July 2024 in Diabetes Care
Verified
Journal Article
Open access
PDF file
IHIrl B. Hirsch
Irl B. Hirsch
RBRoy W. Beck
Roy W. Beck
MMMartin Chase Marak
Martin Chase Marak
PCPeter Calhoun
Peter Calhoun
AMAdham Mottalib
Adham Mottalib
IGINHALE-3 Study Group
INHALE-3 Study Group
OBJECTIVE: To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS: A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS: The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS: Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.