Eda Cengiz

Eda Cengiz

Auto-generated profile, based on publicly available information

Eda Cengiz

University of California, San Francisco, San Francisco, CA, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2009 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
ECEda Cengiz
Eda Cengiz
WTWilliam V. Tamborlane
William V. Tamborlane
Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, while raising questions about the relationships between interstitial and blood glucose levels. This article will review the differences between interstitial and blood glucose and some of the challenges in measuring interstitial glucose levels accurately.

13 October 2020 in Diabetologia
Verified
Journal Article
Open access
PDF file
OMOthmar Moser
Othmar Moser
MRMichael C Riddell
Michael C Riddell
MEMax L Eckstein
Max L Eckstein
PAPeter Adolfsson
Peter Adolfsson
RRRémi Rabasa-Lhoret
Rémi Rabasa-Lhoret
Julia MaderJulia Mader
Julia Mader
Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (i.e. before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes. Graphical abstract

2 June 2021 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
ECErin Cobry
Erin Cobry
LKLauren Kanapka
Lauren Kanapka
ECEda Cengiz
Eda Cengiz
LCLori Carria
Lori Carria
LELaya Ekhlaspour
Laya Ekhlaspour
RWR. Paul Wadwa
R. Paul Wadwa
Introduction: Hybrid closed-loop systems increase time-in-range (TIR) and reduce glycemic variability. Person-reported outcomes (PROs) are essential to assess the utility of new devices and their impact on quality of life. This article focuses on the PROs for pediatric participants (ages 6–13 years) with type 1 diabetes (T1D) and their parents during a trial using the Tandem Control-IQ system, which was shown to increase TIR and improve other glycemic metrics. Research Design and Methods: One hundred and one children 6 to 13 years old with T1D were randomly assigned to closed-loop control (CLC) or sensor-augmented pump (SAP) in a 16-week randomized clinical trial with extension to 28 weeks during which the SAP group crossed over to CLC. Health-related quality of life and treatment satisfaction measures were obtained from children and their parents at baseline, 16 weeks, and 28 weeks. Results: Neither the children in the CLC group nor their parents had statistically significant changes in PRO outcomes compared with the SAP group at the end of the 16-week randomized controlled trial and the 28-week extension. Parents in the CLC group reported nonsignificant improvements in some PRO scores when compared with the SAP group at 16 weeks, which were sustained at 28 weeks. Sleep scores for parents improved from “poor sleep quality” to “adequate sleep quality” between baseline and 16 weeks, however, the change in scores was not statistically different between groups. Conclusions: Children with T1D who used the Control-IQ system did not experience increased burden compared with those using SAP based on person-reported outcomes from the children and their parents. Clinical Trials Registration: NCT03844789

1 April 2009 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
ECEda Cengiz
Eda Cengiz
KSKarena L. Swan
Karena L. Swan
WTWilliam V. Tamborlane
William V. Tamborlane
GSGarry M. Steil
Garry M. Steil
ASAmy T. Steffen
Amy T. Steffen
SWStuart A. Weinzimer
Stuart A. Weinzimer
Objectives: It has been proposed that the first step towards a closed-loop artificial pancreas might be to use a continuous glucose sensor to automatically suspend the basal insulin delivery based on projected low sensor glucose values. Methods: We reviewed our recent experience with an artificial pancreas system, utilizing a proportional-integrative-derivative (PID) algorithm, in 17 adolescents with type 1 diabetes (T1D) to assess the safety and efficacy of this maneuver. Results: During 34 h of closed-loop automated insulin delivery, 18 pump suspensions ≥60 min (90 ± 18 min) occurred in eight subjects. Sensor glucose levels fell from 159 ± 42 mg/dL to a nadir of 72 ± 13 mg/dL. Corresponding plasma glucose levels fell from 168 ± 51 to 72 ± 16 mg/dL, with values <60 mg/dL recorded in only four of the 18 events. Conclusions: These data suggest that automatic pump suspension using the PID algorithm may be an effective means to prevent hypoglycemia in youth with T1D.

6 October 2024 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
DKDavid C. Klonoff
David C. Klonoff
Guido FreckmannGuido Freckmann
Guido Freckmann
SPStefan Pleus
Stefan Pleus
BKBoris P. Kovatchev
Boris P. Kovatchev
DKDavid Kerr
David Kerr
MKMichael A. Kohn
Michael A. Kohn
Introduction: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). Methods: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool—the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. Results: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. Conclusion: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.

16 February 2023 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
JHJingtong Huang
Jingtong Huang
AYAndrea M. Yeung
Andrea M. Yeung
RBRichard M. Bergenstal
Richard M. Bergenstal
KCKristin Castorino
Kristin Castorino
ECEda Cengiz
Eda Cengiz
DKDavid C. Klonoff
David C. Klonoff
Ketone bodies are an energy substrate produced by the liver and used during states of low carbohydrate availability, such as fasting or prolonged exercise. High ketone concentrations can be present with insulin insufficiency and are a key finding in diabetic ketoacidosis (DKA). During states of insulin deficiency, lipolysis increases and a flood of circulating free fatty acids is converted in the liver into ketone bodies—mainly beta-hydroxybutyrate and acetoacetate. During DKA, beta-hydroxybutyrate is the predominant ketone in blood. As DKA resolves, beta-hydroxybutyrate is oxidized to acetoacetate, which is the predominant ketone in the urine. Because of this lag, a urine ketone test might be increasing even as DKA is resolving. Point-of-care tests are available for self-testing of blood ketones and urine ketones through measurement of beta-hydroxybutyrate and acetoacetate and are cleared by the US Food and Drug Administration (FDA). Acetone forms through spontaneous decarboxylation of acetoacetate and can be measured in exhaled breath, but currently no device is FDA-cleared for this purpose. Recently, technology has been announced for measuring beta-hydroxybutyrate in interstitial fluid. Measurement of ketones can be helpful to assess compliance with low carbohydrate diets; assessment of acidosis associated with alcohol use, in conjunction with SGLT2 inhibitors and immune checkpoint inhibitor therapy, both of which can increase the risk of DKA; and to identify DKA due to insulin deficiency. This article reviews the challenges and shortcomings of ketone testing in diabetes treatment and summarizes emerging trends in the measurement of ketones in the blood, urine, breath, and interstitial fluid.