H. C. McEvoy

H. C. McEvoy

Auto-generated profile, based on publicly available information

H. C. McEvoy

National Physical Laboratory

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2016 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
EWEmma Woolliams
Emma Woolliams
KAK. Anhalt
K. Anhalt
MBM. Ballico
M. Ballico
PBP. Bloembergen
P. Bloembergen
FBF. Bourson
F. Bourson
ZYZ. Yuan
Z. Yuan
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.

1 January 2006 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
RSR. Simpson
R. Simpson
GMGraham MacHin
Graham MacHin
HMH. McEvoy
H. McEvoy
RRR. Rusby
R. Rusby
Patient temperature is a fundamental physiological measurement used primarily for observation and diagnosis, for example during surgery, intensive care, recuperation, or treatment. A variety of thermometers are used clinically and these can be separated into two categories, either contact (oral thermometers, rectal thermometers and temporal strips), or non-contact (ear thermometers, temporal thermometers and thermal imagers). To have the maximum confidence in the clinical performance of the temperature measurement instrument it is strongly desirable that the device be traceably calibrated to the International Temperature Scale of 1990 (ITS-90). Lack of traceable calibrations accredited to ISO17025 can lead to unreliability in temperature measurement and in some cases can have a deleterious effect on patient care. The National Physical Laboratory (NPL) maintains and disseminates the ITS-90 for contact and non-contact thermometry in the UK. The importance of accredited traceable calibrations and an outline of contact and non-contact thermometry standards are given here.

28 March 2016 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
MSM. Sadli
M. Sadli
GMGraham MacHin
Graham MacHin
KAK. Anhalt
K. Anhalt
FBF. Bourson
F. Bourson
SBS. Briaudeau
S. Briaudeau
SSS. G. R. Salim
S. G. R. Salim
The mise-en-pratique for the definition of the kelvin at high temperatures will formally allow dissemination of thermodynamic temperature either directly or mediated through high-temperature fixed points (HTFPs). In this paper, these two distinct dissemination methods are evaluated, namely source-based and detector-based. This was achieved by performing two distinct dissemination trials: one based on HTFPs, the other based on absolutely calibrated radiation thermometers or filter radiometers. These trials involved six national metrology institutes in Europe in the frame of the European Metrology Research Programme joint project ‘Implementing the new kelvin’ (InK). The results have shown that both dissemination routes are possible, with similar standard uncertainties of 1–2 K, over the range 1273–2773 K, showing that, depending on the facilities available in the laboratory , it will soon be possible to disseminate thermodynamic temperatures above 1273 K to users by either of the two methods with uncertainties comparable to the current temperature scale.

27 October 2020 in Measurement Science and Technology
Verified
Journal Article
Closed access
HMHelen McEvoy
Helen McEvoy
DLDave H Lowe
Dave H Lowe
RURobin J Underwood
Robin J Underwood
MPMichael de Podesta
Michael de Podesta
GMGraham MacHin
Graham MacHin
HYHoward W Yoon
Howard W Yoon
We report new developments in instrumentation and techniques for both acoustic (speed of sound) and radiometric primary thermometry methods. These include both new cylindrical resonators for extending acoustic gas thermometry to higher temperatures and absolute radiation thermometers incorporating InGaAs detectors to extend primary radiometry to lower temperatures than can be achieved using Si-detector based instruments. These new approaches have been established in order to determine the difference between thermodynamic temperature, T , and the International Temperature Scale of 1990 (the ITS-90), T 90 , over the temperature range from 430 K to 1358 K as part of the three-year EMPIR project ‘Implementing the new kelvin 2' (InK2). This paper describes the facilities and measurement methodologies for measuring T — T 90 at each of the different institutes, along with an assessment of the target uncertainties. The work is ongoing, but we anticipate that the results of these measurements will ultimately be pooled to provide consensus values of T — T 90 with associated estimated uncertainties. These consensus values will initially feed into the technical annex of the mise en pratique for the definition of the kelvin (MeP-K-19) and, if required, will be used to help to provide a foundation for any future temperature scale.

15 October 2013 in Metrologia
Verified
Journal Article
Closed access
PDF file
HMH C McEvoy
H C McEvoy
MSM Sadli
M Sadli
FBF Bourson
F Bourson
SBS Briaudeau
S Briaudeau
BRB Rougié
B Rougié
The silver and copper fixed-point blackbody sources of NPL were directly compared with those of LNE-Cnam using an IKE LP3 and an IKE LP5 at three wavelengths (650 nm, 795 nm and 903 nm). The two silver fixed points and the two copper fixed points were in excellent agreement with each other, with a difference of 11 mK for the silver and within 16 mK for the copper, with an expanded measurement uncertainty of between 10 mK and 20 mK depending on the pyrometer used. The temperature interval between the silver and copper freezing points was also measured using combinations of all four fixed points. The results with the NPL LP3 gave a value for the silver–copper temperature interval of 122.89 °C with an expanded uncertainty of 30 mK; those with the LNE-Cnam LP5 gave a temperature interval of 122.87 °C also with an expanded uncertainty of 30 mK; this compares with the ITS-90 value of 122.84 °C.

11 October 2007 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
HMH. C. McEvoy
H. C. McEvoy
DLD. H. Lowe
D. H. Lowe
MOM. Owen
M. Owen