Michael de Podesta

Michael de Podesta

Auto-generated profile, based on publicly available information

Michael de Podesta

National Physical Laboratory

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2013 in Metrologia
Verified
Journal Article
Closed access
PDF file
MPMichael de Podesta
Michael de Podesta
RURobin Underwood
Robin Underwood
GSGavin Sutton
Gavin Sutton
PMPaul Morantz
Paul Morantz
PHPeter Harris
Peter Harris
GMGraham Machin
Graham Machin
The Comité international des poids et mesures (CIPM) has projected a major revision of the International System of Units (SI) in which all of the base units will be defined by fixing the values of fundamental constants of nature. In preparation for this we have carried out a new, low-uncertainty determination of the Boltzmann constant, kB, in terms of which the SI unit of temperature, the kelvin, can be re-defined. We have evaluated kB from exceptionally accurate measurements of the speed of sound in argon gas which can be related directly to the mean molecular kinetic energy, . Our new estimate is kB = 1.380 651 56 (98) × 10−23 J K−1 with a relative standard uncertainty uR = 0.71 × 10−6.

5 February 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
JFJoachim Fischer
Joachim Fischer
BFBernd Fellmuth
Bernd Fellmuth
CGChristof Gaiser
Christof Gaiser
TZThorsten Zandt
Thorsten Zandt
LPLaurent Pitre
Laurent Pitre
DCDolores del Campo
Dolores del Campo
The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10 −23 J K −1 . The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10 −7 , corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k , important for the new definition of the kelvin and performed in the last decade, is given.

29 May 2010 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
GSGavin Sutton
Gavin Sutton
RURobin Underwood
Robin Underwood
LPLaurent Pitre
Laurent Pitre
MPMichael de Podesta
Michael de Podesta
SVStaf Valkiers
Staf Valkiers

28 February 2018 in Metrologia
Verified
Journal Article
Open access
PDF file
MPMichael de Podesta
Michael de Podesta
SBStephanie Bell
Stephanie Bell
RURobin J Underwood
Robin J Underwood

18 January 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
AMAndrea Merlone
Andrea Merlone
Francesca SannaFrancesca Sanna
Francesca Sanna
GBGaber Beges
Gaber Beges
SBS Bell
S Bell
GBG Beltramino
G Beltramino
ACAlicia Gonzalez Calvo
Alicia Gonzalez Calvo
Launched in 2011 within the European Metrology Research Programme (EMRP) of EURAMET, the joint research project ‘MeteoMet’—Metrology for Meteorology—is the largest EMRP consortium; national metrology institutes, universities, meteorological and climate agencies, research institutes, collaborators and manufacturers are working together, developing new metrological techniques, as well as improving existing ones, for use in meteorological observations and climate records. The project focuses on humidity in the upper and surface atmosphere, air temperature, surface and deep-sea temperatures, soil moisture, salinity, permafrost temperature, precipitation, and the snow albedo effect on air temperature. All tasks are performed using a rigorous metrological approach and include the design and study of new sensors, new calibration facilities, the investigation of sensor characteristics, improved techniques for measurements of essential climate variables with uncertainty evaluation, traceability, laboratory proficiency and the inclusion of field influencing parameters, long-lasting measurements, and campaigns in remote and extreme areas. The vision for MeteoMet is to take a step further towards establishing full data comparability, coherency, consistency, and long-term continuity, through a comprehensive evaluation of the measurement uncertainties for the quantities involved in the global climate observing systems and the derived observations. The improvement in quality of essential climate variables records, through the inclusion of measurement uncertainty budgets, will also highlight possible strategies for the reduction of the uncertainty. This contribution presents selected highlights of the MeteoMet project and reviews the main ongoing activities, tasks and deliverables, with a view to its possible future evolution and extended impact.

10 May 2020 in Quarterly Journal of the Royal Meteorological Society
Verified
Journal Article
Open access
PDF file
SBStephen Burt
Stephen Burt
MPMichael de Podesta
Michael de Podesta
Guidelines in the Guide to Meteorological Instruments and Methods of Observation (the CIMO guide) of the World Meteorological Organization (WMO, published 2014, updated 2017, section 2.1.3.3, Response times of thermometers) recommend that the 63% response time τ for an air temperature sensor be 20 s, although – as airflow speed influences response time – the minimum airflow speed at which this applies should also be specified in the document. A 63% response time τ63 = 20 s implies that 95% of a step change be registered within 3τ63 or 60 s, the WMO recommended averaging interval for air temperature: rapid air temperature changes on this time‐scale are not uncommon, often associated with convective squalls, frontal systems or sea breeze circulations. An alternative way of expressing the effect of the time constant is that in air whose temperature is changing at 0.1 K·min−1 the thermometer would lag by approximately 0.03 K.To assess whether this response time specification was realistic, we have undertaken an experimental and theoretical study of the time constants of meteorological thermometers. Laboratory wind tunnel tests were undertaken to quantify 63% and 95% response times of 25 commercial 100 Ω platinum resistance thermometers (PRTs) of various sizes (length and sheath diameter) from five manufacturers. The test results revealed a fourfold difference in response times between different sensors: none of the PRTs tested met the CIMO response time guideline at a ventilation speed of 1 m·s−1 assumed typical of passively ventilated thermometer shields such as Stevenson‐type thermometer screens. A theoretical model of the sensors was devised which matched the experimental behaviour with regard to the most important contributing factors, namely ventilation rate and sensor diameter. Finally, suggestions and recommendations for operational air temperature sensor adoption and future sensor development are included.