Kun Qian

Kun Qian

Auto-generated profile, based on publicly available information

Kun Qian

National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
LYLin Yang
Lin Yang
SAStephen Antonelli
Stephen Antonelli
SCShirish Chodankar
Shirish Chodankar
JBJames Byrnes
James Byrnes
ELEdwin Lazo
Edwin Lazo
KQKun Qian
Kun Qian
This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q-range of typically 0.006–3.2 Å−1. Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

25 February 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDieter K. Schneider
Dieter K. Schneider
WSWuxian Shi
Wuxian Shi
BABabak Andi
Babak Andi
JJJean Jakoncic
Jean Jakoncic
YGYuan Gao
Yuan Gao
MFMartin Fuchs
Martin Fuchs
Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

21 October 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDieter K. Schneider
Dieter K. Schneider
ASAlexei Soares
Alexei Soares
ELEdwin O. Lazo
Edwin O. Lazo
DKDale F. Kreitler
Dale F. Kreitler
KQKun Qian
Kun Qian
JJJean Jakoncic
Jean Jakoncic
The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s−1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

23 August 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ELEdwin O. Lazo
Edwin O. Lazo
SAStephen Antonelli
Stephen Antonelli
JAJun Aishima
Jun Aishima
HBHerbert J. Bernstein
Herbert J. Bernstein
DBDileep Bhogadi
Dileep Bhogadi
JJJean Jakoncic
Jean Jakoncic

1 January 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ELEdwin O. Lazo
Edwin O. Lazo
SAStephen Antonelli
Stephen Antonelli
JAJun Aishima
Jun Aishima
HBHerbert J. Bernstein
Herbert J. Bernstein
DBDileep Bhogadi
Dileep Bhogadi
JJJean Jakoncic
Jean Jakoncic
A correction in the paper by Lazo et al. [(2021). J. Synchrotron Rad. 28, 1649–1661] is made.

26 June 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
JAJ. Aishima
J. Aishima
BAB. Andi
B. Andi
LBL. Berman
L. Berman
JBJ. Byrnes
J. Byrnes
SCS. Chodankar
S. Chodankar
SMS. McSweeney
S. McSweeney
The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.