Marcel Fiebrandt

Marcel Fiebrandt

Auto-generated profile, based on publicly available information

Marcel Fiebrandt

Institute of Electrical Engineering and Plasma Technology, Ruhr-University Bochum 3 , Bochum, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2016 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
MRMarina Raguse
Marina Raguse
MFMarcel Fiebrandt
Marcel Fiebrandt
BDBenjamin Denis
Benjamin Denis
Katharina StapelmannKatharina Stapelmann
Katharina Stapelmann
PEPatrick Eichenberger
Patrick Eichenberger
Ralf MoellerRalf Moeller
Ralf Moeller
Low-pressure plasmas have been evaluated for their potential in biomedical and defense purposes. The sterilizing effect of plasma can be attributed to several active agents, including (V)UV radiation, charged particles, radical species, neutral and excited atoms and molecules, and the electric field. Spores of Bacillus subtilis were used as a bioindicator and a genetic model system to study the sporicidal effects of low-pressure plasma decontamination. Wild-type spores, spores lacking the major protective coat layers (inner, outer, and crust), pigmentation-deficient spores or spore impaired in encasement (a late step in coat assembly) were systematically tested for their resistance to low-pressure argon, hydrogen, and oxygen plasmas with and without admixtures. We demonstrate that low-pressure plasma discharges of argon and oxygen discharges cause significant physical damage to spore surface structures as visualized by atomic force microscopy. Spore resistance to low-pressure plasma was primarily dependent on the presence of the inner, and outer spore coat layers as well as spore encasement, with minor or less importance of the crust and spore pigmentation, whereas spore inactivation itself was strongly influenced by the gas composition and operational settings.

18 October 2018 in Plasma Processes and Polymers
Verified
Journal Article
Open access
PDF file
MFMarcel Fiebrandt
Marcel Fiebrandt
JLJan‐Wilm Lackmann
Jan‐Wilm Lackmann
Katharina StapelmannKatharina Stapelmann
Katharina Stapelmann
The development of new sterilization methods is still a major topic. The need for new techniques arises from the development of new instruments and the usage of different materials. Especially in the case of plastics with their beneficial properties, for example, in the field of implantology, plasma sterilization is seen as a promising alternative to the standard methods. However, 50 years after the first patent and although low‐pressure plasmas show excellent inactivation performance (>log 6 reduction), only one commercial system is available on the market for a distinct application. We will give a short review about known plasma sterilization mechanisms, the different plasma sterilization systems in use, analyze possible challenges for an industrial process and comment on possible solutions for a broader acceptance and utilization of low‐pressure plasma sterilization.

1 April 2016 in Applied and Environmental Microbiology
Verified
Journal Article
Closed access
PDF file
MRMarina Raguse
Marina Raguse
MFMarcel Fiebrandt
Marcel Fiebrandt
Katharina StapelmannKatharina Stapelmann
Katharina Stapelmann
KMKazimierz Madela
Kazimierz Madela
MLMichael Laue
Michael Laue
Ralf MoellerRalf Moeller
Ralf Moeller
Novel decontamination technologies, including cold low-pressure plasma and blue light (400 nm), are promising alternatives to conventional surface decontamination methods. However, the standardization of the assessment of such sterilization processes remains to be accomplished. Bacterial endospores of the genera Bacillus and Geobacillus are frequently used as biological indicators (BIs) of sterility. Ensuring standardized and reproducible BIs for reliable testing procedures is a significant problem in industrial settings. In this study, an electrically driven spray deposition device was developed, allowing fast, reproducible, and homogeneous preparation of Bacillus subtilis 168 spore monolayers on glass surfaces. A detailed description of the structural design as well as the operating principle of the spraying device is given. The reproducible formation of spore monolayers of up to 5 × 10 7 spores per sample was verified by scanning electron microscopy. Surface inactivation studies revealed that monolayered spores were inactivated by UV-C (254 nm), low-pressure argon plasma (500 W, 10 Pa, 100 standard cubic cm per min), and blue light (400 nm) significantly faster than multilayered spores were. We have thus succeeded in the uniform preparation of reproducible, highly concentrated spore monolayers with the potential to generate BIs for a variety of nonpenetrating surface decontamination techniques.

1 July 2013 in Astrobiology
Verified
Journal Article
Closed access
Katharina StapelmannKatharina Stapelmann
Katharina Stapelmann
MFMarcel Fiebrandt
Marcel Fiebrandt
MRMarina Raguse
Marina Raguse
PAPeter Awakowicz
Peter Awakowicz
GRGünther Reitz
Günther Reitz
Ralf MoellerRalf Moeller
Ralf Moeller
A special focus area of planetary protection is the monitoring, control, and reduction of microbial contaminations that are detected on spacecraft components and hardware during and after assembly. In this study, wild-type spores of Bacillus pumilus SAFR-032 (a persistent spacecraft assembly facility isolate) and the laboratory model organism B. subtilis 168 were used to study the effects of low-pressure plasma, with hydrogen alone and in combination with oxygen and evaporated hydrogen peroxide as a process gas, on spore survival, which was determined by a colony formation assay. Spores of B. pumilus SAFR-032 and B. subtilis 168 were deposited with an aseptic technique onto the surface of stainless steel screws to simulate a spore-contaminated spacecraft hardware component, and were subsequently exposed to different plasmas and hydrogen peroxide conditions in a very high frequency capacitively coupled plasma reactor (VHF-CCP) to reduce the spore burden. Spores of the spacecraft isolate B. pumilus SAFR-032 were significantly more resistant to plasma treatment than spores of B. subtilis 168. The use of low-pressure plasma with an additional treatment of evaporated hydrogen peroxide also led to an enhanced spore inactivation that surpassed either single treatment when applied alone, which indicates the potential application of this method as a fast and suitable way to reduce spore-contaminated spacecraft hardware components for planetary protection purposes. Key Words: Bacillus spores—Contamination—Spacecraft hardware—Plasma sterilization—Planetary protection. Astrobiology 13, 597–606.

9 October 2017 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
AKA. Kanitz
A. Kanitz
JHJ. S. Hoppius
J. S. Hoppius
MFM. Fiebrandt
M. Fiebrandt
PAP. Awakowicz
P. Awakowicz
CECemal Esen
Cemal Esen
EGEvgeny Gurevich
Evgeny Gurevich

7 July 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
MFMarcel Fiebrandt
Marcel Fiebrandt
MOMoritz Oberberg
Moritz Oberberg
PAPeter Awakowicz
Peter Awakowicz
The results of a Multipole Resonance Probe (MRP) are compared to a Langmuir probe in measuring the electron density in Ar, H2, N2, and O2 mixtures. The MRP was designed for measurements in industry processes, i.e., coating or etching. To evaluate a possible influence on the MRP measurement due to molecular gases, different plasmas with increasing molecular gas content in a double inductively coupled plasma at 5 Pa and 10 Pa at 500 W are used. The determined electron densities from the MRP and the Langmuir probe slightly differ in H2 and N2 diluted argon plasmas, but diverge significantly with oxygen. In pure molecular gas plasmas, electron densities measured with the MRP are always higher than those measured with the Langmuir Probe, in particular, in oxygen containing mixtures. The differences can be attributed to etching of the tungsten wire in the Ar:O2 mixtures and rf distortion in the pure molecular discharges. The influence of a non-Maxwellian electron energy distribution function, negative ions or secondary electron emission seems to be of no or only minor importance.