1 September 2005 in Journal of Structural Engineering
The influence of mass irregularity on building seismic response is examined for an eight-story concentrically braced steel frame with different setback configurations resulting in sudden reductions in plan dimensions and seismic weight along the height of the structure. Three locations of mass discontinuity were considered (25, 50, and 75% of the building height), together with two ratios of seismic weight (200 and 300%). A reference regular structure was also considered for comparison. The design of each structure was performed according to the proposed 2005 National Building Code of Canada NBCC provisions using two analysis methods: The equivalent static force procedure and the response spectrum analysis method. Although severe, the mass irregularity conditions considered in this study were found to have a limited negative impact on the seismic performance of the structures designed with the static analysis method. The performance of irregular structures exhibiting lower performance could be improved by...
1 November 2018 in Journal of Structural Engineering
This paper presents the extension of controlled rocking technology to steel bridge piers through analytical expression and finite-element (FE) simulation. As an outcome of the rocking behavior, the seismic damage is prevented due to reduced flexural stresses in the columns. However, local buckling can happen if the column wall thickness is too thin, which has detrimental impacts, including the loss of self-centering ability and reduced lateral load/deformation capacity. A simple analytical method is proposed to predict the monotonic rocking response for preliminary design purposes. When using more-detailed models and FE analysis, it is shown that localized inelastic deformations of the column can occur upon rocking and the simple force distribution at the column base can cause an overestimation of lateral load capacity. The use of a base plate can lead to a higher lateral load capacity and less damage to the column by improving the stress distribution at the base of the column. To account for the base plate, previously proposed modified monolithic beam analogy (MBA) was expanded in this study, referenced as extended MBA (EMBA) to predict the rocking column lateral load-displacement response. An optimized design can be achieved with a lighter cross section in the upper part of the column where longitudinal straining is limited. Different axially yielding elements comprised of tension-only, tension-compression, and buckling-restrained energy dissipators (EDs) are investigated. For EDs with comparable force capacities, the study indicates that energy dissipation is increased from the former to the latter dissipator type, while the lateral load capacity of the system remains almost the same. The proposed pier exhibits recentering capability, high ductility, and stable hysteretic response with the majority of damage confined within external sacrificial elements.
1 February 2013 in Journal of Composites for Construction
This paper investigates the behavior of two 8-story cantilevered RC shear walls rehabilitated using carbon fiber-reinforced polymer (CFRP) composite sheets when subjected to base excitations from a shake table. The two original reduced size walls (1:0.429) were tested on the shake table of École Polytechnique de Montréal to investigate the effect of higher modes of vibration on the behavior of multistory RC walls. The walls were subjected to several levels of ground motion excitation that matches the design spectrum of Montréal city in Québec, Canada. The original walls showed significant inelastic deformations at the 6th-story level in addition to those at the base plastic hinge. After the shake table tests on each of the two original walls, the damaged walls were rehabilitated and resubjected to the same levels of the ground motion excitations. This paper focuses on the FRP-rehabilitation of the original walls. The rehabilitation scheme for the two walls aimed to increase the flexural and shear ...
1 November 2016 in Journal of Structural Engineering
A seismic design strategy, which is intended to be implemented within the framework of the U.S. seismic design provisions for steel structures, is presented for single-story steel concentrically braced frames that are divided into two tiers. In this method, the columns are designed to resist the axial loads acting in combination with the in-plane flexural demand resulting from uneven distribution of brace inelastic deformations over the frame height. This design procedure, which establishes enhanced requirements beyond the 2010 edition of the U.S. seismic design provisions, prevents concentration of deformation in one tier and causes frame nonlinear deformation to be distributed between the tiers. The column bending moments depend on the story shear resistance that develops in each tier when the bracing members are at buckling and in the postbuckling range. The method also aims to control tier drifts to protect the bracing members from excessive inelastic demand, which could cause brace fracture. ...
1 December 2003 in Journal of Structural Engineering
An experimental program was undertaken to investigate the inelastic seismic response of metal deck roofing systems. The load carrying capacity of roof diaphragms for low-rise steel buildings, subjected to lateral loads from wind and/or earthquakes, is directly dependent on the performance of the connections. This paper provides information on the inelastic cyclic response, including load versus displacement hysteresis and energy absorption capacity of 144 deck-to-frame screwed, powder-actuated fastener, and welded connection tests for different steel deck and structure thickness. Powder-actuated fastener connections were able to provide the highest energy dissipation results, followed closely by screwed connections. In many cases, the welded connections exhibited significant ultimate capacities, but failed at small displacements, resulting in low energy dissipation values. However, when welds with washers were used, the ductility and energy absorption ability of the connection were substantially improved.
1 August 2013 in Canadian Journal of Civil Engineering
This paper provides a summary of the damage to industrial facilities in the Mw 8.8 Chile earthquake of 27 February 2010. The types of damage observed include failure of elevated tanks, collapse and cracking of concrete silos, buckling of steel silos, collapse of conveyor systems, failure of steel bins, and failure of anchor rods. Damage to industrial buildings included buckling of bracing members, failure of brace connections, shear failures of reinforced concrete columns, and shear failures of heavily loaded steel girders. Aspects of the current Chilean design code for industrial structures are reviewed and discussed. Recommendations are proposed for the development of Canadian seismic design provisions for industrial structures.