Byron Jay Peterson

Byron Jay Peterson

Auto-generated profile, based on publicly available information

Byron Jay Peterson

11 National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, Gifu, 509-5292, JAPAN

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Plasma and Fusion Research
Verified
Journal Article
Open access
BPByron J. Peterson
Byron J. Peterson
SKShigeru Konoshima
Shigeru Konoshima
AKArtem Yu. Kostryukov
Artem Yu. Kostryukov
DSDongcheol Seo
Dongcheol Seo
YLYi Liu
Yi Liu
TTthe JT-60U team
the JT-60U team
An overview of the research and development of imaging bolometers giving a perspective on the applicability of this diagnostic to a fusion reactor is presented. Traditionally the total power lost from a high temperature, magnetically confined plasma through radiation and neutral particles has been measured using one dimensional arrays of resistive bolometers. The large number of signal wires associated with these resistive bolometers poses hazards not only at the vacuum interface, but also in the loss of electrical contacts that has been observed in the presence of fusion reactor levels of neutron flux. Imaging bolometers, on the other hand, use the infrared radiation from the absorbing metal foil to transfer the signal through the vacuum interface and out from behind a neutron shield. Recently a prototype imaging bolometer known as the InfraRed imaging Video Bolometer has been deployed on the JT-60U tokamak which demonstrates the ability of this diagnostic to operate in a reactor environment. The application of computed tomography demonstrates the ability of one imaging bolometer with a semi-tangential view to produce images of the plasma emissivity. In addition, new detector foil development promises to strengthen the foil and increase the sensitivity by an order of magnitude

26 March 2003 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
YLY. Liu
Y. Liu
AKA. Yu. Kostrioukov
A. Yu. Kostrioukov
BPB. J. Peterson
B. J. Peterson
LGLHD Experiment Group
LHD Experiment Group
Both one-dimensional (1D) and two-dimensional (2D) tomographic reconstruction of the total radiation power distribution from the large helical device (LHD) was based on the data obtained from absolute extreme ultraviolet silicon photodiodes. Two arrays (16 and 19 channels) installed in the normal LHD cross section (constant toroidal angle) provided simple and reliable 1D poloidally symmetric radiation profile reconstruction. The data obtained from two other arrays (20 and 20 channels) were used for 2D reconstruction of the radiation distribution in a semitangential plasma cross section. Using a 2D peeling away algorithm, improved by a feedback procedure, enabled reconstruction of several Fourier harmonics at each magnetic flux surface. These measurement and analysis techniques have enabled us to visualize asymmetries in plasma emission due to pellet and gas fueling.

30 September 2021 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
KMKiyofumi Mukai
Kiyofumi Mukai
SMSuguru Masuzaki
Suguru Masuzaki
YHYuki Hayashi
Yuki Hayashi
TOTetsutarou Oishi
Tetsutarou Oishi
Chihiro SuzukiChihiro Suzuki
Chihiro Suzuki
BPByron Jay Peterson
Byron Jay Peterson
Multi-species impurity seeding is an advanced operation scenario to mitigate the divertor heat load for the realization of future fusion reactors. In the Large Helical Device (LHD), divertor detachment is successfully sustained using higher-Z (krypton, Kr) and lower-Z (neon, Ne) superimposed seeding. Emission from Kr impurities is drastically enhanced if it is followed by Ne seeding. Plasma radiation can be enhanced even at the upstream region in the edge plasma compared with Ne only seeded plasmas with suppression of impurity accumulation toward the central plasma. The characteristics of divertor heat load reduction and energy confinement are comparable between the Kr+Ne seeding and Ne only seeding under the same radiation fraction. However, while the detachment in Ne only seeding is transient, the detachment in Kr+Ne seeding is stable. It indicates that multi-species impurity seeding can be competitive for steady-state operation although further investigation is desired about the balance between divertor heat load reduction, impurity screening, and confinement degradation. The Kr emission enhancement is strongly affected by electron density and temperature at the last closed flux surface resulting in impurity penetration.

1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
BPByron J. Peterson
Byron J. Peterson
RRRoger Reichle
Roger Reichle
SPSantosh Pandya
Santosh Pandya
MOMartin G. O’mUllane
Martin G. O’mUllane
KMKiyofumi Mukai
Kiyofumi Mukai
An infrared imaging video bolometer (IRVB) is proposed for ITER having a tangential view of the entire ITER cross section. For the initial estimate of the signal level, a 840 m3 plasma is assumed to uniformly radiate 67.3 MW. A more detailed estimate of the signal strength is provided by synthetic images based on radiation data from SOLPS and SANCO models for the edge and core plasma, respectively. The Pt foil used as the radiation absorber would have the dimensions of 7 × 9 cm2 and a thickness of 16 μm that will stop 95% of the radiated power. Two different InSb based IR cameras having a sensitivity of 15 mK are considered for measuring the temperature rise of the foil due to the radiation. The first has 1280 × 1024 pixel2 and a frame rate of 105 fps. The second has 640 × 512 pixel2 and a frame rate of 1000 fps. The resulting IRVBs have 40 × 30 pixel2, 10 ms time resolution, and a signal to noise ratio (SNR) of 17 and 20 × 15 pixel2, 3 ms time resolution, and a SNR of 35, respectively. The synthetic image data give SNRs of 30 and 59, respectively.

1 March 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
PGP. L. van de Giessen
P. L. van de Giessen
GKG. Kawamura
G. Kawamura
SBS. Borling
S. Borling
KMK. Mukai
K. Mukai
BPB. J. Peterson
B. J. Peterson
Diagnosing the amount of radiated power is an important research goal for fusion devices. This research aims at better understanding and diagnosing the radiated power from the Large Helical Device (LHD). The current radiated power estimate in the LHD is based on one wide-angle resistive bolometer. Because the estimate stems from one bolometer location toroidally and has a wide-angle poloidal view, this estimate does not take into account toroidal and poloidal radiation asymmetries that are observed in the LHD in discharges with gas puffing. This research develops a method based on the EMC3-Eirene model to calculate the set of coefficients for a weighted-sum method of estimating the radiated power. This study calculates these coefficients by using a least-squares method to solve for a coefficient set, using a variety of simulated cases generated by the EMC3-Eirene model, combined with corresponding geometric radiated power density considerations. If this set of coefficients is multiplied by the detector signal of each bolometer and summed up, this gives a total radiated power estimate. This new estimate takes into account toroidal and poloidal asymmetries by using the bolometer channels viewing different toroidal and poloidal locations, thereby reducing the estimation error and providing information about toroidal asymmetries.

1 June 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
KMK. Mukai
K. Mukai
BPB. J. Peterson
B. J. Peterson
NEN. Ezumi
N. Ezumi
NSN. Shigematsu
N. Shigematsu
SOS. Ohshima
S. Ohshima
RMR. Matoike
R. Matoike
The sensitivity of an infrared imaging video bolometer (IRVB) was improved for the measurement of relatively low energy plasma radiation from the viewpoint of the metal foil absorber material. The photon energy of the radiation was considered up to 1 keV for the divertor plasma measurement. The thickness of the foil absorber was evaluated not only for conventional heavy elements, e.g., platinum, but also for light elements by the relation between the photon energy and attenuation length and by mechanical strength. A heat-transfer calculation using ANSYS suggested that light elements with practical foil thickness provide a higher temperature rise of the foil absorber compared with heavier elements with practical foil thickness. The maximum of the temperature rise was evaluated using He–Ne laser irradiation onto absorber samples. The material dependence of the temperature rise has a similar tendency between calculations and experiments. Experimentally, the sensitivity of the IRVB improved from 280 to 110 µW/cm2 using titanium with 1 µm thickness compared with conventional platinum with 2.5 µm thickness. Consequently, the signal-to-noise ratio of the IRVB could be improved from 2.8 to 9.1.