Alan Getgood

Alan Getgood

Auto-generated profile, based on publicly available information

Alan Getgood

Bone and Joint Institute, Western University, London, Ontario, Canada

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Arthroscopy
Verified
Journal Article
Closed access
ARAlex Rezansoff
Alex Rezansoff
AFAndrew D. Firth
Andrew D. Firth
DBDianne M. Bryant
Dianne M. Bryant
RLRobert Litchfield
Robert Litchfield
RMRobert G. McCormack
Robert G. McCormack
AGAlan M.J. Getgood
Alan M.J. Getgood

1 January 2019 in Clinics in Sports Medicine
Verified
Journal Article
Closed access
KHKyla Huebner
Kyla Huebner
RFRachel M. Frank
Rachel M. Frank
AGAlan Getgood
Alan Getgood

1 December 2018 in The Knee
Verified
Journal Article
Closed access
MNMadeleine Norris
Madeleine Norris
GCGillian Corbo
Gillian Corbo
KBKamal Banga
Kamal Banga
MJMarjorie Johnson
Marjorie Johnson
MSMartin Sandig
Martin Sandig
TBTimothy A Burkhart
Timothy A Burkhart

14 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAgnes Berta
Agnes Berta
MSMatthew Shive
Matthew Shive
ALAndrew K. Lynn
Andrew K. Lynn
AGAlan Getgood
Alan Getgood
STSaara Totterman
Saara Totterman
LHLászló Hangody
László Hangody
Scaffolds are thought to be a key element needed for successful cartilage repair treatments, and this prospective extension study aimed to evaluate long-term structural and clinical outcomes following osteochondral defect treatment with a cell-free biphasic scaffold. Structural outcomes were assessed using quantitative 3-D magnetic resonance imaging (MRI) and morphological segmentation to determine the percentage of defect filling and repair cartilage T2 relaxation times, and clinical outcomes were determined with the modified Cincinnati Rating System, and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Seventeen subjects with osteochondral defects in the knee were treated with ChondroMimetic scaffolds, from which 15 returned for long-term evaluation at a mean follow-up of 7.9 ± 0.3 years. The defects treated were trochlear donor sites for mosaicplasty in 13 subjects, and medial femoral condyle defects in 2 subjects. MRI analysis of scaffold-treated defects found a mean total defect filling of 95.2 ± 3.6%, and a tissue mean T2 relaxation time of 52.5 ± 4.8 ms, which was identical to the T2 of ipsilateral control cartilage (52.3 ± 9.2 ms). The overall modified Cincinnati Rating System score was statistically significant from baseline (p = 0.0065), and KOOS subscales were equivalent to other cartilage repair techniques. ChondroMimetic treatment resulted in a consistently high degree of osteochondral defect filling with durable, cartilage-like repair tissue at 7.9 years, potentially associated with clinical improvement.

3 June 2024 in The American Journal of Sports Medicine
Verified
Journal Article
Open access
WBWouter Beel
Wouter Beel
TVThiago Vivacqua
Thiago Vivacqua
RWRyan Willing
Ryan Willing
AGAlan Getgood
Alan Getgood
Background: New techniques have been proposed to better address anteromedial rotatory instability in a medial collateral ligament (MCL)–injured knee that require an extra graft and more surgical implants, which might not be feasible in every clinical setting. Purpose: To investigate if improved resistance to anteromedial rotatory instability can be achieved by using a single-graft, double-bundle (DB) MCL reconstruction with a proximal fixation more anteriorly on the tibia, in comparison with the gold standard single-bundle (SB) MCL reconstruction. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen human cadaveric knees were tested using a 6 degrees of freedom robotic simulator in intact knee, superficial MCL/deep MCL–deficient, and reconstruction states. Three different reconstructions were tested: DB MCL no proximal tibial fixation and DB and SB MCL reconstruction with proximal tibial fixation. Knee kinematics were recorded at 0°, 30°, 60°, and 90° of knee flexion for the following measurements: 8 N·m of valgus rotation (VR), 5 N·m of external tibial rotation, 5 N·m of internal tibial rotation, combined 89 N of anterior tibial translation and 5 N·m of external rotation for anteromedial rotation (AMR) and anteromedial translation (AMT). The differences between each state for every measurement were analyzed with VR and AMR/AMT as primary outcomes. Results: Cutting the superficial MCL/deep MCL increased VR and AMR/AMT in all knee positions except at 90° for VR ( P < .05). All reconstructions restored VR to the intact state except at 90° of knee flexion ( P < .05). The DB MCL no proximal tibial fixation reconstruction could not restore intact AMR/AMT kinematics in any knee position ( P < .05). Adding an anterior-based proximal tibial fixation restored intact AMR/AMT kinematics at ≥30° of knee flexion except at 90° for AMT ( P < .05). The SB MCL reconstruction could not restore intact AMR/AMT kinematics at 0° and 90° of knee flexion ( P < .05). Conclusion: In this in vitro cadaveric study, a DB MCL reconstruction with anteriorly placed proximal tibial fixation was able to control AMR and AMT better than the gold standard SB MCL reconstruction. Clinical Relevance: In patients with anteromedial rotatory instability and valgus instability, a DB MCL reconstruction may be superior to the SB MCL reconstruction, without causing extra surgical morbidity or additional costs.

15 July 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ABAlexandra M. Blokker
Alexandra M. Blokker
AGAlan M. Getgood
Alan M. Getgood
NCNathan J. Curiale
Nathan J. Curiale
HNHristo N. Nikolov
Hristo N. Nikolov
JLJustin G. Laing
Justin G. Laing
TBTimothy A Burkhart
Timothy A Burkhart
Currently available knee joint kinematic tracking systems fail to nondestructively capture the subtle variation in joint and soft tissue kinematics that occur in native, injured, and reconstructed joint states. Microcomputed tomography (CT) imaging has the potential as a noninvasive, high-resolution kinematic tracking system, but no dynamic simulators exist to take advantage of this. The purpose of this work was to develop and assess a novel micro-CT compatible knee joint simulator to quantify the knee joint's kinematic and kinetic response to clinically (e.g., pivot shift test) and functionally (e.g., gait) relevant loading. The simulator applies closed-loop, load control over four degrees-of-freedom (DOF) (internal/external rotation, varus/valgus rotation, anterior/posterior translation, and compression/distraction), and static control over a fifth degree-of-freedom (flexion/extension). Simulator accuracy (e.g., load error) and repeatability (e.g., coefficient of variation) were assessed with a cylindrical rubber tubing structure and a human cadaveric knee joint by applying clinically and functionally relevant loads along all active axes. Micro-CT images acquired of the joint at a loaded state were then used to calculate joint kinematics. The simulator loaded both the rubber tubing and the cadaveric specimen to within 0.1% of the load target, with an intertrial coefficient of variation below 0.1% for all clinically relevant loading protocols. The resultant kinematics calculated from the acquired images agreed with previously published values, and produced errors of 1.66 mm, 0.90 mm, 4.41 deg, and 1.60 deg with respect to anterior translation, compression, internal rotation, and valgus rotation, respectively. All images were free of artifacts and showed knee joint displacements in response to clinically and functionally loading with isotropic CT image voxel spacing of 0.15 mm. The results of this study demonstrate that the joint-motion simulator is capable of applying accurate, clinically and functionally relevant loads to cadaveric knee joints, concurrent with micro-CT imaging. Nondestructive tracking of bony landmarks allows for the precise calculation of joint kinematics with less error than traditional optical tracking systems.