Ronghuai Qi

Ronghuai Qi

Auto-generated profile, based on publicly available information

Ronghuai Qi

Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation Laboratory, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
TBTimothy A. Brumfiel
Timothy A. Brumfiel
RQRonghuai Qi
Ronghuai Qi
SRSharan Ravigopal
Sharan Ravigopal
JDJaydev P. Desai
Jaydev P. Desai
Many intravascular procedures are prefaced by the placement of a slender wire called a guidewire. Steering these guidewires is met with challenges in controlling the distal end along with the possibility of damaging vessel walls, or even perforation, which can be fatal. To this end, utilizing robotic guidewires can improve steerability and enable force feedback through intrinsic force sensing. Enabling force sensing contains challenges such as discrete sensor placements in continuous structures and non-unique force distributions for a given deflection. In this work, we utilize image feedback and a Cosserat rod model to estimate and localize forces along the body of a micro-scale tendon-driven guidewire robot. This includes additional modeling of friction and hysteresis that is often neglected for force sensing. The model is tested on a variety of notched nitinol tubes under gravity loading with the shape predictions having an average RMSE of 0.46 mm. Utilization of friction and hysteresis models provide shape predictions with an RMSE of 1.22 mm compared to an uncompensated model (RMSE ${=}$ 1.62 mm) for approximately 180° bends. The methods presented are able to localize forces with an average error of 4.79 mm (5.15% of the length) while force magnitudes are estimated with an average error of 13.03 mN.

19 October 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
NNNamrata U. Nayar
Namrata U. Nayar
RQRonghuai Qi
Ronghuai Qi
JDJaydev P. Desai
Jaydev P. Desai
Minimally-invasive surgeries using transcatheter approaches and sophisticated imaging modalities are gaining popularity to treat mitral regurgitation (MR). This paper proposes the next generation of a robotic catheter to deliver an implant onto the mitral valve (MV) through a transseptal approach. The proposed robot has an outer diameter (OD) of 5.7 mm, a rigid distal end length of 20 mm, a prismatic tube that can be advanced by 50-60 mm, and a bending joint that can easily bend 120° to reach the valve opening. The implant can be rotated 75° bidirectionally by the distal torsion joint to orient it with the MV leaflet for precise implantation. The robotic joints are modeled individually, the forward and inverse kinematics are derived, and the robot motion validation is carried out through experimentation. A modified kinematics (MK) model, Prandtl-Ishlinskii (PI) hysteresis model, and hybrid of MK and PI model are used to compensate for the catheter nonlinearities. A preliminary study is conducted to evaluate if force sensing can be used to compensate for the effects of fluid flow. Also, the implantation procedure is demonstrated in a phantom heart.

12 July 2021 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Open access
RQRonghuai Qi
Ronghuai Qi
AKAmir Khajepour
Amir Khajepour
WMWilliam Melek
William Melek
This article presents redundancy resolution and disturbance rejection via torque optimization in hybrid cable-driven robots (HCDRs). To begin with, we present a redundant HCDR for nonlinear whole-body system modeling and model reduction. Based on the reduced dynamic model, two new methods are proposed to solve the redundancy resolution problem: 1) joint-space torque optimization for actuated joints (TOAJ) and 2) joint-space torque optimization for actuated and unactuated joints (TOAUJ), and they can be extended to other HCDRs. Compared to the existing approaches, this article provides the first solution (TOAUJ-based method) for HCDRs that can solve the redundancy resolution problem as well as disturbance rejection. Additionally, this article develops detailed algorithms targeting TOAJ and TOAUJ implementation. A simple yet effective controller is designed for analysis and validation. Case studies are conducted to evaluate the performance of TOAJ and TOAUJ. The results show the effectiveness of the aforementioned approaches.

30 August 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
RQRonghuai Qi
Ronghuai Qi
NNNamrata U. Nayar
Namrata U. Nayar
JDJaydev P. Desai
Jaydev P. Desai
Mitral regurgitation (MR) is one of the most common valvular abnormalities, and the gold-standard for treatment is surgical mitral valve repair/replacement. Most patients with severe MR are over the age of 75, which makes open-heart surgery challenging. Thus, minimally invasive surgeries using transcatheter approaches are gaining popularity. This paper proposes the next generation of a robotic transcatheter delivery system for the mitral valve implant that focuses on the design of the actuation system, modeling, and task space control. The proposed actuation system is compact while still enabling bidirectional torsion, bending, and prismatic joint motion. A pulley structure is employed to actuate the torsion and bending joints using only one motor per joint in conjunction with an antagonistic passive spring to reduce tendon slack. The robotic transcatheter is also optimized to increase its stability and reduce bending deflection. An inverse kinematics model (with an optimization algorithm), singularity analysis method, and joint hysteresis and compensation model are developed and verified. Finally, a task space controller is also proposed. Experiments, including trajectory tracking and demonstrations of the robot motion in an ex vivo porcine heart and a phantom heart through a tortuous path are presented.

7 April 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
RQRonghuai Qi
Ronghuai Qi
NNNamrata U. Nayar
Namrata U. Nayar
JDJaydev P. Desai
Jaydev P. Desai
Mitral regurgitation (MR) is the most common type of valvular heart disease, affecting over 2% of the world population, and the gold-standard treatment is surgical mitral valve repair/replacement. Compared to open-heart surgeries, minimally invasive surgeries (MIS) using transcatheter approaches have become popular because of their notable benefits such as less postoperative pain, shorter hospital stay, and faster recovery time. However, commercially available catheters are manually actuated, causing over-exposure of clinical staff to radiation and increased risk of human error during medical interventions. To tackle this problem, in this letter, we propose a telerobotic transcatheter delivery system, which consists of a robotic catheter (5.7 mm OD), a reinforced guide tube (1.11 m length), and an actuation system. We present the robotic system design, fabrication of key components, and static model of reinforced quadlumen tube. The robot interface design enables the user to intuitively control the robot. We demonstrate the effectiveness of the telerobotic transcatheter delivery system and reinforced quadlumen tube in a realistic human cardiovascular phantom for preclinical evaluation.

14 September 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
TBTimothy A. Brumfiel
Timothy A. Brumfiel
RQRonghuai Qi
Ronghuai Qi
CCColey Chapman
Coley Chapman
ARAsif Rashid
Asif Rashid
SMShreyes N. Melkote
Shreyes N. Melkote
JDJaydev P. Desai
Jaydev P. Desai
Minimally invasive procedures, such as endoscopic third ventriculostomy (ETV), benefit from the increased dexterity and safety that surgical continuum robots can bring. However, due to their natural compliance, new compatible end-effectors, such as graspers or scissors, must be developed and their actuation must be considered when developing the robotic structures in which they are housed due to the inherent coupling that will be introduced. In this paper, we integrate a tendon-driven meso-scale grasper, with a closed configuration diameter of 1.69 mm, into a 2 degree-of-freedom (DoF) tendon-driven neurosurgical robot with an outer diameter of less than 2 mm. Furthermore, the kinematics of the grasper is validated and an analysis of the coupling between the grasper and the robotic joints is conducted in order to evaluate the design performance.