25 September 2026 in Energy
20 October 2026 in SSRN Electronic Journal
Axial heat-supply distribution is an important consideration in thermal management of methanol steam reforming (MSR) reactors. This study experimentally investigates the effects of imposed axial wall-temperature set-point profiles on internal temperature fields and reactor performance in a five-zone fixed-bed reformer. Increasing, uniform, and decreasing profiles were compared at a fixed mean wall-temperature set point of 250 °C under identical feed conditions. Discrete axial–radial temperature measurements revealed that uniform wall-temperature settings did not produce a uniform internal bed-temperature field. Among the tested configurations, the increasing profile from 200 to 300 °C achieved the highest methanol conversion of 93.19% and H₂ production rate of 40.82 L min⁻¹, with an outlet CO mole fraction of 1.88%. The calculated reaction-enthalpy-based thermal utilization ratio reached 63.43% under this configuration. A dimensionless set-temperature configuration index, G, was introduced to characterize the imposed axial profiles. A two-parameter complementary log–log correlation described the overall conversion trend with R² = 0.8397. The findings demonstrate the importance of distinguishing imposed thermal boundary conditions from actual internal temperature responses when evaluating heat-supply configurations for fixed-bed MSR reactors.
16 July 2026 in SSRN Electronic Journal
Compressed air energy storage (CAES) is a promising technology for integrating high penetration renewable power into power grids. The afterburning type CAES integrated with molten salt thermal energy storage (MS-CAES) is a hybrid energy storage system with multiple discharging modes to accommodate variable output power. However, owing to various system configurations and heat sources, the MS-CAES system exhibits drastically different dynamic behaviors under diverse discharge modes. To clarify the evolution of dynamic characteristics of the MS-CAES, a multi-module dynamic model coupled with time scale evaluation indicators was established and validated in this paper. Then, two typical discharge modes, namely the gas combustion heating discharge mode (DMG) and the molten salt heating discharge mode (DMM), were comparatively studied. The results reveal that the dynamic responses and thermodynamic performances of the MS-CAES differ considerably across various discharge modes, primarily owing to variations in heat source characteristics. As the inlet boundary ramp rate increases from 3% min-1 to 18% min-1, the power undershoot increases to 1.04 and 0.73 MW for DMG and DMM, while the maximum negative deviations of the key expander inlet temperatures reach 73.41 and 59.70 K, respectively. DMG responds faster because gas combustion heating provides a faster thermal response, but the exergy efficiency of DMG is low because of exergy destruction in the combustion chamber. In contrast, DMM achieves higher exergy efficiency than DMG, whereas the serial thermal inertia of molten salt heat exchangers prolongs temperature recovery.
7 September 2026 in Energy
26 August 2026 in eceee Summer Study proceedings
Extended abstract 2-071-26 The accelerating transition toward a decentralised, high-renewable energy system is fundamentally changing the relationship between supply, demand, and grid infrastructure. This necessitates moving beyond traditional temporal load shifting to unlock new forms of flexibility that address location-specific challenges. This work introduces and defines Spatial Demand Flexibility: the intentional and coordinated adjustment of the geographical location where electricity is consumed or stored to resolve localized grid issues, enhance system resilience, and improve overall energy system efficiency and equity. A clarification worth making is that SDF is not a substitute for temporal shifting, but rather a crucial supplementary mechanism that focuses on where energy is used, and delivers additional value by capitalising on the heterogeneity of energy imbalances across different geographical areas. We establish its critical importance in solving the omnipresent challenge of grid congestion due to overloaded assets and limited transmission capacity issues. SDF effectively acts as a ‘virtual wire’, enabling non-wired grid balancing alternatives to defer or eliminate costly physical network upgrades by resolving local bottlenecks through load relocation. We analyse the conditions under which SDF delivers value, highlighting that its benefits must outweigh the cost and inconvenience of implementation and that it is especially valuable when temporal flexibility is unavailable or less efficient. A core tenet is that SDF must not be treated as an isolated resource, as the effectiveness of a spatial demand shift is inextricably linked to the temporal dynamics of demand as well as assets’ response time. From a policy perspective, integrating SDF concepts directly supports UK’s transition towards Ofgem’s Regional Energy Strategic Plans regime to resolve localised capacity constraints. These plans are meant to guide distribution network investments for 2028–2033. To do so effectively, policy makers must mandate spatial foresight by embedding dynamic analyses of projected energy fluxes across regions into planning frameworks. Moving beyond traditional siloed planning approaches to embrace these spatial flexibility concepts ensures that future developments are strategic and coordinated. Ultimately, this spatial lens is crucial for building resilient, efficient, and equitable infrastructure networks that maximise local economic utility. Read full Download presentation.
14 November 2026 in Energy