Emanuele Parisi

Emanuele Parisi

Auto-generated profile, based on publicly available information

Emanuele Parisi

Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Microelectronics Journal
Verified
Journal Article
Closed access
Domenico CaputoDomenico Caputo
Domenico Caputo
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
Augusto NascettiAugusto Nascetti
Augusto Nascetti
EPE. Parisi
E. Parisi
RSRiccardo Scipinotti
Riccardo Scipinotti

11 November 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
FCFrancesca Costantini
Francesca Costantini
EPEmanuele Parisi
Emanuele Parisi
MNMarco Nardecchia
Marco Nardecchia
MTMario Tucci
Mario Tucci
Domenico CaputoDomenico Caputo
Domenico Caputo
This paper presents the development of a compact optoelectronic device suitable for on-chip detection of fluorescent molecules. In order to obtain a highly integrated device, a long-pass multi-dielectric filter has been integrated with thin-film amorphous silicon photosensors on a single glass substrate. Filter rejects the excitation light, allowing the reduction of the distance between the source and the fluorescent site and avoiding the use of external optical component. The compatibility of the technological processes determined the materials and the temporal sequence of the device fabrication. The developed device has been designed for the fluorescence detection of ruthenium complex based molecules and tested, as a proof of concept, for the detection of double-stranded DNA down to 0.5 ng. Results demonstrate the correct operation of the integrated system in both rejecting the excitation light and in detecting the fluorescent signal, demonstrating the suitability of this optoelectronic platform in practical biomedical applications.

1 June 2015
Verified
Conference Paper
Closed access
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
GPGiulia Petrucci
Giulia Petrucci
Domenico CaputoDomenico Caputo
Domenico Caputo
SASamia Alameddine
Samia Alameddine
MCMatteo Carpentiero
Matteo Carpentiero
Augusto NascettiAugusto Nascetti
Augusto Nascetti
In this paper we present a system able to perform thermal treatments on lab-on-chip devices fabricated on glass substrates. The system includes a thin film resistor acting as heater and thin film hydrogenated amorphous silicon diodes acting as temperature sensors. An electronic system controls the lab-on-chip temperature through a Proportional-IntegralDerivative algorithm. In particular, an electronic board infers the system temperature measuring the voltage across the amorphous silicon diodes and drives the heater to achieve the set-point temperature. Taking into account the 16-bit ADC resolution and the sensors sensitivity, which is around 3.6 mV/ o C, we estimate that our system is able to detect temperature variation as low as 3.5·10 -3o C. Furthermore, the experimental results show that the system is able to stabilize the system temperature with a precision better than 0.1 o C.

1 February 2015
Verified
Conference Paper
Closed access
GPGiulia Petrucci
Giulia Petrucci
Domenico CaputoDomenico Caputo
Domenico Caputo
Augusto NascettiAugusto Nascetti
Augusto Nascetti
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
EPEmanuele Parisi
Emanuele Parisi
AZAndleeb Zahra
Andleeb Zahra
This paper presents the design, fabrication and characterization of a thin film heater functional for thermal treatments in lab-on-chip system. The spatial temperature distribution determined by different heater geometries has been studied through electro-thermal simulations by using COMSOL Multiphysics. The heater showing the more uniform temperature distribution has been subsequently fabricated and characterized. A very good agreement between modeled and measured data has been attained. Results show a spatial temperature distribution of about ±1°C over an area comparable to the heater area and a directly USB powered heater, demonstrating the suitability of the proposed device for lab-on-chip thermal applications.

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
Domenico CaputoDomenico Caputo
Domenico Caputo
EPEmanuele Parisi
Emanuele Parisi
ANAugusto Nascetti
Augusto Nascetti
Mara MirasoliMara Mirasoli
Mara Mirasoli
MNMarco Nardecchia
Marco Nardecchia
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare
This work presents the development and testing of an integrated system for on-chip detection of thermochemiluminescent biomolecules. The activation energy of the reaction is provided by a transparent structure of thin film heaters deposited on one side of a glass substrate. Light, passing through the substrate, reaches an array of amorphous silicon differential structure deposited on the opposite side of the glass substrate. The structure is designed to perform differential current measurements between a light- shielded diode, whose current is sensitive only to temperature, and a photosensor, sensitive to both incident light and temperature. The device therefore balances the thermal variations of the photodiode current and reduces the dark-current noise. These features make the presented system very appealing as highly miniaturized micro-analytical devices for biosensing applications

9 September 2017 in Lecture Notes in Electrical Engineering
Verified
Book Chapter
Closed access
PDF file
Domenico CaputoDomenico Caputo
Domenico Caputo
EPEmanuele Parisi
Emanuele Parisi
ANAugusto Nascetti
Augusto Nascetti
MTMario Tucci
Mario Tucci
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare