Giulia Petrucci

Giulia Petrucci

Auto-generated profile, based on publicly available information

Giulia Petrucci

Department of Information, Electronics and Communication Engineering, University of Rome "La Sapienza", Via Eudossiana 18, 00184, Rome, Italy

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FCFrancesca Costantini
Francesca Costantini
CSCristiana Sberna
Cristiana Sberna
GPGiulia Petrucci
Giulia Petrucci
MRMassimo Reverberi
Massimo Reverberi
FDFabio Domenici
Fabio Domenici
Domenico CaputoDomenico Caputo
Domenico Caputo

1 July 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
GPG. Petrucci
G. Petrucci
Domenico CaputoDomenico Caputo
Domenico Caputo
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
FCF. Costantini
F. Costantini
ILI. Legnini
I. Legnini
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare

1 December 2015 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
FCFrancesca Costantini
Francesca Costantini
CSCristiana Sberna
Cristiana Sberna
GPGiulia Petrucci
Giulia Petrucci
CMCesare Manetti
Cesare Manetti
Giampiero de CesareGiampiero de Cesare
Giampiero de Cesare
Domenico CaputoDomenico Caputo
Domenico Caputo
This work presents a lab-on-chip system, which combines a glass-polydimethilsiloxane microfluidic network and an array of amorphous silicon photosensors for the diagnosis and follow-up of Celiac disease. The microfluidic chip implements an on-chip enzyme-linked immunosorbent assay (ELISA), relying on a sandwich immunoassay between antibodies against gliadin peptides (GPs) and a secondary antibody marked with horseradish peroxidase (Ig-HRP). This enzyme catalyzes a chemiluminescent reaction, whose light intensity is detected by the amorphous silicon photosensors and transduced into an electrical signal that can be processed to recognize the presence of antibodies against GPs in the serum of people affected by Celiac syndrome.The correct operation of the developed lab-on-chip has been demonstrated using rabbit serum in the microfluidic ELISA. In particular, optimizing the dilution factors of both sera and Ig-HRP samples in the flowing solutions, the specific and non-specific antibodies against GPs can be successfully distinguished, showing the suitability of the presented device to effectively screen celiac disease epitopes

1 June 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
ASA. Scorzoni
A. Scorzoni
Domenico CaputoDomenico Caputo
Domenico Caputo
GPG. Petrucci
G. Petrucci
PPP. Placidi
P. Placidi
SZStefano Zampolli
Stefano Zampolli
Augusto NascettiAugusto Nascetti
Augusto Nascetti

1 June 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
Mara MirasoliMara Mirasoli
Mara Mirasoli
FBFrancesca Bonvicini
Francesca Bonvicini
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
GPG. Petrucci
G. Petrucci
MZMartina Zangheri
Martina Zangheri
Augusto NascettiAugusto Nascetti
Augusto Nascetti

1 June 2015
Verified
Conference Paper
Closed access
NICOLA LOVECCHIONICOLA LOVECCHIO
NICOLA LOVECCHIO
GPGiulia Petrucci
Giulia Petrucci
Domenico CaputoDomenico Caputo
Domenico Caputo
SASamia Alameddine
Samia Alameddine
MCMatteo Carpentiero
Matteo Carpentiero
Augusto NascettiAugusto Nascetti
Augusto Nascetti
In this paper we present a system able to perform thermal treatments on lab-on-chip devices fabricated on glass substrates. The system includes a thin film resistor acting as heater and thin film hydrogenated amorphous silicon diodes acting as temperature sensors. An electronic system controls the lab-on-chip temperature through a Proportional-IntegralDerivative algorithm. In particular, an electronic board infers the system temperature measuring the voltage across the amorphous silicon diodes and drives the heater to achieve the set-point temperature. Taking into account the 16-bit ADC resolution and the sensors sensitivity, which is around 3.6 mV/ o C, we estimate that our system is able to detect temperature variation as low as 3.5·10 -3o C. Furthermore, the experimental results show that the system is able to stabilize the system temperature with a precision better than 0.1 o C.