Background. The success of cementless total hip arthroplasty (THA) relies on its primary mechanical stability and secondary biological fixation, which can be assessed by specific exams like dual-energy x-ray absorptiometry (DEXA) or computed tomography (CT). We evaluated the bone adaptation of a cementless primary THA using a validated image analysis tool and plain radiographs.Material and Methods. Patients who received a cementless THA from September 2020 to July 2022 were included in the study. Clinical scores and X-rays were collected prospectively. Relative bone density (RBD) was calculated for each patient, using Rossler validated method with Image-J software, to assess bone density changes after THA.Results. 155 patients at a mean age of 56.4 years (range 31-84) were followed up for 38.5 months. Harris Hip Score was 92.2 at the latest follow-up. Radiographically, all the cups were positioned in the Lewinnek safe zone. Five cups showed non-progressive radiolucent lines. RBD showed a significant decrease in Gruen zone 1, while the percentage difference in the other zones ranged from -9% to +4%. In the cohort, there were 2 intraoperative fractures treated with cerclage wires. One patient had a superficial infection, and another one had a deep infection.Conclusions. 1. ImageJ stands out as a robust tool for the quantitative assessment of osteointegration in uncemented hip implants. 2. Its ability to analyse regular x-ray data with precision supports better clinical outcomes. 3. By incorporating ImageJ into routine assessments, orthopaedic surgeons can achieve a more accurate understanding of bone-implant interactions, leading to optimized patient care and improved implant survival rates analysis. 4. The consideration of cost and time efficiency further underscores the value of ImageJ in clinical practice, making it a valuable asset.
30 April 2024 in Ortopedia Traumatologia Rehabilitacja
Background. Total hip arthroplasty in patients with rheumatoid arthritis is difficult and leads to worse implant survival and higher risk for complications compared to osteoarthritis. Poor periacetabular bone quality might challenge the stability of the acetabular cup. Contemporary 3D-printed highly-porous titanium cup designs have become the benchmark for cementless implants; however, their usefulness in rheumatoid arthritis is still unclear. The purpose of this study was to assess the short-term results of the use of a highly-porous 3D-printed acetabular titanium cup in patients with rheumatoid arthritis.Material and methods. We studied a consecutive series of RA patients who underwent cementless THA between 2019 and 2020 in our center with the same 3D-printed highly-porous titanium acetabular cup. All patients were evaluated prospectively for a minimum 3-year follow-up with the Harris hip score, VAS and Roles and Maudsley score. Radiographic assessment focused on evidence of cup osseointegration. Results. 37 RA patients, mean age at surgery of 51.3 years, were included. Mean follow-up was 3.2 years (3 to 4 years). By the last follow-up visit, the Harris hip score had increased significantly from 37.8 to 88.5, VAS had decreased from 6.1 to 1.0 and excellent satisfaction for 31 patients. All 5 Moore’s radiographic signs were present in 35 hips, with only 4 signs present in the remaining 2 hips, thus indicating complete osseointegration of all cups. There were no complications on the acetabular side but one intraoperative proximal calcar fracture. Conclusion. 3D-printed highly porous implants used in primary THA worked well in patients with rheumatoid arthritis, showing excellent osseointegration and good clinical results in the short term.
30 June 2023 in Ortopedia Traumatologia Rehabilitacja
We aim to compare the preoperative planning radiographs of 50 patients in whom both a short stem and its homonymous standard version were programmed, focusing on the preservation of the neck and the invasion of the femoral shaft. The secondary objective was to evaluate the 50 preoperative radiographs with the 50 postoperative radiographs in which the short stem was implanted, measuring the real invasion of the diaphysis and the real preservation of the femoral neck. We measured cut level at the femoral neck and diaphyseal invasion in 50 preoperative x-rays where an Alteon Neck Preserving Stem (ANPS) was templated and we compared it with 50 preoperative x-rays where an Alteon Taper Wedge Stem (ATWS) was templated. After surgery, we compared both parameters previously measured in the preoperative x-rays with the 50 postoperative radiographs where the short stem was implanted obtaining the real bone preservation at the femoral neck and the real diaphyseal invasion length. For templating comparison, mean bone preservation at the femoral neck was 14.87mm (SD 3.64) for the ANPS group and 9.94mm (SD 8.39) for the ATWS group (p <0.001). The mean diaphyseal bone invasion was 47.21mm (SD 5.89) and 76.77mm (SD 8.39) for ANPS and ATWS respectively (p <0.001). After surgery, the mean postoperative bone preservation at the femoral neck was 15.08mm (SD 3.1) with a mean of 0.17mm (SD 0.51) more preservation in the preoperative group. 1. ANPS allow bone preservation with limited diaphyseal invasion when compared with his homonymous ATWS in the preoperative templates. 2. ANPS showed a good correlation between preoperative radiographs and real bone preservation of the femoral neck and invasion of the femoral shaft.
31 July 2025 in Ortopedia Traumatologia Rehabilitacja
Background. Peri-incisional numbness commonly follows total knee arthroplasty (TKA), primarily due to injury to the infrapatellar branch of the saphenous nerve. While this sensory deficit is often perceived by patients as a minor inconvenience, its effect on clinical and functional outcomes remains debated. To evaluate the prevalence, temporal evolution, and functional impact of postoperative numbness in patients undergoing primary cemented TKA. Secondary objectives included measuring the area of numbness (AON) over time and identifying the rate of persistent skin numbness (PSN).Material and methods. This prospective observational study included 437 patients (267 female, 170 male; mean age 64.1 8.6 years) who underwent primary cemented TKA using a standard medial parapatellar approach. Surgery duration, tourniquet time, wound length, hospital stay, Knee Society Score (KSS), and Roles and Maudsley satisfaction scores were recorded. Sensory assessments for light touch and pinprick were conducted at 6 weeks, 3 months, 6 months, and 1 year postoperatively. AON was quantified at each time point.Results. At 6 weeks postoperatively, 144 patients (32.9%) reported numbness (AON: 10.1 3.6 cm; KSS: 63.8 6.1). Numbness declined over time: 97 patients (22.2%) at 3 months (AON: 8.0 2.1 cm), 54 patients (13%) at 6 months (AON: 6.5 1.6 cm), and 38 patients (8.7%) at 1 year (AON: 4.2 2.8 cm). KSS and satisfaction scores improved across follow-up assessments. At final follow-up, 67% of patients rated outcomes as “excellent,” and only 11% reported fair or poor satisfaction. Persistent numbness correlated weakly with patient dissatisfaction. Poor satisfaction was linked to complications such as wound dehiscence (1.6%) and patellar tracking pain (3.6%).Conclusions. 1. Peri-incisional numbness is common after TKA but shows significant spontaneous improvement over 12 months. 2. Persistent numbness does not significantly impact clinical or satisfaction outcomes for the majority of patients. 3. Patients should be informed preoperatively about this expected, generally minor, and self-limiting symptom.