Marta Katarzyna Skrok

Marta Katarzyna Skrok

Auto-generated profile, based on publicly available information

Marta Katarzyna Skrok

Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Torun, Torun, Poland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2025 in Biomedical Optics Express
Verified
Journal Article
Open access
STSzymon Tamborski
Szymon Tamborski
MSMarta K. Skrok
Marta K. Skrok
MHMatt S. Hepburn
Matt S. Hepburn
MMMateusz Maniewski
Mateusz Maniewski
MZMarek Zdrenka
Marek Zdrenka
BKBrendan F. Kennedy
Brendan F. Kennedy
Prostate cancer is a significant global health issue. To advance diagnostic and treatment procedures, such as image-guided needle biopsy, optical imaging methods offering high spatial resolution have been proposed. Optical coherence tomography (OCT) allows for detailed visualization of prostate microarchitecture in three dimensions; however, it does not reliably differentiate tumors from surrounding healthy tissue. In this study, we use wide-field quantitative micro-elastography (QME) to image the micro-scale mechanical properties of freshly excised human prostate to provide additional contrast of tumor, which is known to exhibit increased stiffness. In our approach, we generate volumetric OCT, strain, and elasticity images over a field-of-view (x × y × z) of 46 × 46 × 1 mm3. We validate the contrast obtained in our images through co-registration with standard histology images.

1 February 2021 in Optometry and Vision Science
Verified
Journal Article
Open access
MSMarta K. Msc Skrok
Marta K. Msc Skrok
DADavid Alonso‐Caneiro
David Alonso‐Caneiro
JPJoanna P-D
Joanna P-D
DSDamian Siedlecki
Damian Siedlecki
Supplemental digital content is available in the text. SIGNIFICANCE: This study evaluates the reliability and validity of an automatic method of the external and internal limbal points identification from anterior segment optical coherence tomography (OCT) images in comparison with manual delineation. PURPOSE: The purpose of this work was to evaluate the repeatability and precision of a previously proposed automatic method of external and internal limbal points identification and to compare them with the manual delineation by experienced clinicians in terms of limbus diameter. METHODS: Optical coherence tomography tomograms obtained for 12 healthy volunteers without a history of eye diseases were analyzed. Fifteen OCT tomograms were captured for each patient. For all the images, the external and internal limbal points were determined using both the automatic and manual methods. The external and internal limbus diameters were used as the comparative parameter between the methods under consideration. The statistical analysis included mean, standard deviation, the Passing‐Bablok regression, and the Pearson correlation coefficient. RESULTS: A strong linear dependence between the automatic and manual methods was identified. While compared with the subjective estimates from clinicians, the automatic technique overestimated the external limbus diameter (bias equals 0.21 mm for optometrist and 0.23 mm for ophthalmologist) and slightly underestimated the internal limbus diameter (bias equals 0.13 mm for optometrist and 0.04 mm for ophthalmologist). The automatic method showed significantly better repeatability than the manual method in the case of external limbal points identification and comparably high repeatability for internal limbal points recognition. CONCLUSIONS: Because of high precision and excellent repeatability, the automatic method of limbal points identification may be successfully used for estimation of the dynamic changes in the geometry of the anterior segment of the eye, where the large number of captured OCT images needs to be processed automatically with high precision.

30 October 2025 in Behavior Research Methods
Verified
Journal Article
Open access
PDF file
MNMarcus Nyström
Marcus Nyström
DNDiederick C. Niehorster
Diederick C. Niehorster
RHRoy S. Hessels
Roy S. Hessels
RARichard Andersson
Richard Andersson
MSMarta K. Skrok
Marta K. Skrok
IHIgnace T. C. Hooge
Ignace T. C. Hooge
The eyeball is not rigid and deforms during saccades. As a consequence, the saccade waveform recorded by an eye tracker may depend on which structure of the eye is used to estimate eyeball rotation. Here, we systematically describe and compare signals co-recorded from the retina, the cornea (corneal reflection, CR), the pupil, and the lens (fourth Purkinje reflection, P4) during saccades. We found that several commonly used parameters for saccade characterization differ systematically across the signals. For instance, saccades in the retinal signal had earlier onsets compared to saccades in the pupil and the P4 signals. The retinal signal had the smallest saccade amplitude and reached the peak saccade velocity earlier compared to the other signals. At the end of saccades, the retinal signal came to a stop faster than the other signals. We discuss possible explanations that may account for the relationship between the retinal signal and the other signals.

29 June 2026 in Optica
Verified
Journal Article
Open access
SMSeweryn Morawiec
Seweryn Morawiec
MHMatt S. Hepburn
Matt S. Hepburn
MSMarta K. Skrok
Marta K. Skrok
PSPatrycjusz Stremplewski
Patrycjusz Stremplewski
MMMateusz Maniewski
Mateusz Maniewski
BKBrendan F. Kennedy
Brendan F. Kennedy
Optical coherence elastography (OCE) enables label-free imaging of tissue mechanical properties, but conventional scanning implementations have limited volumetric acquisition speed. We present a full-field swept-source optical coherence elastography (FF-SS-OCE) system, based on compressive loading, that provides rapid volumetric imaging of strain at a rate of 2 volumes/s, enabled by an effective OCT A-scan rate of 4.2 MHz, corresponding to an order-of-magnitude increase in imaging speed over previous OCE demonstrations. The system achieves a shot-noise-limited phase sensitivity in volumetric imaging by combining highly parallel signal detection using a full-field configuration, implementation of a common-path interferometer to minimize the impact of environmental noise, a highly stable tunable laser, and active reduction of spatial coherence to reduce cross-talk noise. We demonstrate, for the same signal-to-noise ratio (SNR) of ∼20dB, that FF-SS-OCE provides 41% higher phase sensitivity and 35% higher strain sensitivity compared to a scanning OCT system. We validate the method using structured phantoms and freshly excised human breast tissue, demonstrating rapid visualization of mechanical contrast and showing its potential to discern between tumor and healthy tissue based on their distinct mechanical properties. These results establish FF-SS-OCE as a promising approach for high-speed, high-sensitivity volumetric elastography in biomedical tissue imaging.

31 May 2026
Verified
Conference Paper
Open access
MSMarta Katarzyna Skrok
Marta Katarzyna Skrok
KTKrzysztof Tołpa
Krzysztof Tołpa
RKRobert Konklewski
Robert Konklewski
VPValentyna Pryhodiuk
Valentyna Pryhodiuk
JKJoanna Krzywania-Fifielska
Joanna Krzywania-Fifielska
MSMaciej Szkulmowski
Maciej Szkulmowski