Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.
This paper presents an implementation to enhance the protection scheme of smart distribution grid. In order to improve the existing protection scheme used in Malaysia that is "Current Differential Protection", to a new level of protection that used the idea of combining the "Current Differential Protection" and "Fast Current Protection". This project was developed to increase the efficiency of protection, decrease any unnecessary cost regarding the protection maintenance or equipment used, and space used for installing a particular protection scheme. Besides that, neither "Current Differential Protection" nor "Fast Current Protection" has their own advantages and disadvantages for their perspective protection scheme. The results were proven by simulating the design using PSCAD software, which the new design, combined both theories of "Current Differential Protection" and "Fast Current Protection". The building cost for the new design can be reduced in installation or maintenance.
This project present analysis and implementation of cross blocking feature as the solution for overcoming the mal-operation of the transformer differential relay in sympathetic inrush phenomena. The sympathetic inrush phenomena will occur to the transformers that connected in parallel. The inrush current will flow to the transformer that is already energized when energizing the second transformer on the power system. It will effect a voltage drop and this voltage drop caused the saturation to the already transformer in the negative direction. These phenomena caused the mal-operation of the relay that the main point of this project is to overcome it. The results obtained after designing 100MVA, 33/ 11kV three phase transformer by using PSCAD/ EMTDC simulation. As results, cross blocking method will operate as a block tripping and this method is useful to eliminate mal-operations that occur during the energization of the transformer due of the failure of harmonic restraint function in transformer differential relays. These analyses solve the problem of sympathetic inrush current phenomena.
1 December 2024 in International Journal of Electrical and Computer Engineering (IJECE)
This paper introduces an innovative improvement to impressed current cathodic protection (ICCP) systems by integrating a pulse-feeding technique designed to address metal protection degradation during off-potential periods, a common issue in conventional systems. The proposed system enhances the overall effectiveness and reliability of ICCP, providing consistent corrosion protection for critical metal structures. A notable advantage of this method is its simplicity, utilizing a cost-effective microcontroller for pulse feeding. This approach simplifies integration processes and enhances cost-effectiveness, making it an attractive solution for improving cathodic protection system performance without substantial additional costs. The method addresses conventional ICCP weaknesses by applying a high-frequency pulse current during off-potential periods. This reduces excessive negative charge buildup on metal surfaces during interruptions, boosting the system’s effectiveness and stability. Research laboratory experiments were conducted using pulse width modulation (PWM) on an ATmega328P microcontroller to demonstrate the method’s effectiveness. Additionally, an IoT-monitored ICCP system was developed using an ESP32 microcontroller and the Blynk application. Results highlight the superiority of a 50 kHz pulse feeding frequency in preventing corrosion compared to lower frequencies. Overall, this advancement significantly enhances ICCP systems, providing improved corrosion protection and durability in harsh environments.
This project is to present the transient recovery voltage on circuit breaker in power system network. The transient recovery voltage is a characteristic in power system and will found just only microsecond in the power system network. The objective of this project is to simulate and analysis the transient recovery voltage on circuit breaker. It is to investigate the transient recovery voltage before and after the circuit breaker interrupts and also the transient recovery voltage under the fault. The method used in this project is by simulating the circuit using the PSCAD software. This software will simulate the circuit model and collect some data to give more understanding about transient recovery voltage. This project will continue by analyzing the result based on the data collected. The simulation results are same with the expected results and thus, it show that the simulation results are correct and pre theoretical. In conclusion, the transient recovery voltage affects the breaking capacity of the circuit breaker operation and also affects the power system network operation.
The objective of this study was to evaluate the performance of a triangle loop antenna to assess its use as a potential sensor in partial discharge (PD) impulse signals detection. PD impulse signals were measured over a frequency up to 100 MHz at 3 kV through Needle-Plate Electrode experiment. The experiment was conducted to create an artificial PD acting as a breakdown that causes insulation failure. Subsequently, the characteristic of PD impulse signals was captured by triangle loop antenna with variation of diameters and number of turns. The number of turns is up to three turns and diameters of triangle loop antenna intervals are 6 cm, 8 cm and 10 cm. Then, the Fast Fourier Transforms (FFT) analysis was carried out to measure the frequency bandwidth. The results revealed that an experimental frequency is 32.01 MHz. Then, it can be observed that the amplitude value of peak-to-peak voltage (Vpp) for three turns 10 cm diameter of triangle loop antenna higher than the amplitude value for one turn and two turns of triangle loop antennas.