10 May 2018 in Journal of Radiological Protection
Introduction. The exact level of exposure experienced by nuclear medicine personnel, whose work often requires performing manual procedures involving radioactive isotopes, is associated with the form of radiation source used. The variety of radionuclides and medical procedures, and the yearly increase in the number of patients, as well as the change of the individual dose limit for the lens of the eye from a value of 150 mSv yr −1 to 20 mSv yr −1 , mean that issues of eye lens routine dosimetry become interesting from the radiation protection point of view. Objective. This paper presents an analysis of the exposure of the eye lenses of nuclear medicine department personnel, as well as those of personnel in the facilities that produce radiopharmaceuticals for the purpose of diagnosis by positron emission tomography, from the viewpoint of the advisability of routine eye lens exposure monitoring, taking into account changes in the dose limit for the lens of the eye. Materials and methods. The paper considers the two most commonly used radionuclides for diagnostic purposes 99m Tc, 18 F, and—for therapeutic purposes— 131 I. Dose measurements were made using thermoluminescent detectors. Results. The estimated exposure analysis identifies the cases when the maximum annual value of the personal dose equivalent, in terms of Hp(3), exceeds threefold the new limit value (20 mSv yr −1 ). Conclusions. It is recommended that Hp(3) doses be routinely monitored in the group of radiopharmacists who label pharmaceuticals with the radionuclide 99m Tc and in chemists working in 18 F-FDG quality control departments in production units, where this is carried out manually.
11 October 2016 in Journal of Radiological Protection
18 F-FDG is the most popular radiopharmaceutical used, among others, in oncological diagnostics by PET technique. The production of 18 F-FDG is a multistep process that begins by obtaining the radioisotope 18 F, and subsequently labelling the radiopharmaceutical, as well as quality control of the resulting compound. In each of these stages, the employee has contact with ionizing radiation. The production of 18 F requires the use of a cyclotron device. Currently in Poland, there are 9 centres equipped with a cyclotron for the production of positron-emitting radioisotopes. The monitoring of the occupational exposure to ionizing radiation in these centres is performed by measuring the effective and equivalent dose. Neither of these forms fully reflects the exposure of the worker, which is largely associated with handling procedures. The 18 F radiopharmaceutical preparation process runs automatically, which partially reduces the level of staff exposure, but the quality control step of the pharmaceutical requires handling procedures with a vial containing an activity of a radiopharmaceutical ranging from 4 GBq to 10 GBq. In the work presented, measurements were performed of hand exposure, in units the equivalent dose ( H
p
(0.07)), of the staff who are involved in the procedures of 18 F-FDG production in one of the national production centres. The high-sensitivity thermoluminescent detectors (MCP) were used to measure the doses. The measurements were performed for three groups of workers: operators of the cyclotron, those who produce the 18 F-FDG, and quality control staff. Detectors were placed on the fingertips of the left and right hand, as well as in a standard ring dosemeter location. The results indicate that the largest exposure happens among the group of workers involved in the radiopharmaceutical’s quality control. The doses recorded by the MCP detectors placed on the fingertips during one working day reach a value up to 2 mSv, which may result in exceeding the annual dose limit (500 mSv).
23 November 2018 in Journal of Radiological Protection
Introduction. Obtaining 68 Ga-DOTA-TATE (a radioconjugate consisting of the somatostatin analogue tyrosine-3-octreotate (Tyr3-octreotate or TATE) labelled with the positron emission tomography tracer gallium 68 Ga via the macrocyclic chelating agent dodecanetetraacetic acid (DOTA)) is a complex process and, as with any radiopharmaceutical whose basis is a short-lived radionuclide generator, it is based on a sequence of procedures beginning from the 68 Ge/ 68 Ga generator elution, labelling ligands with a radioisotope, dispensing doses of 68 Ga-DOTA-TATE for patients and finally injection of the preparation to patients. The complexity of this process may contribute to an increased exposure of eye lenses of the staff who perform the above-mentioned procedures, which is especially important at a time when the dose limit on the lens of the eye is being reduced from 150 to 20 mSv yr –1 . Objective. The work presents the exposure of eye lenses of the personnel of a nuclear medicine department who prepare and inject 68 Ga-DOTA-TATE. Materials and methods. Radiochemists and nurses were monitored by dosimetry measurements with thermoluminescent detectors (TLDs). Results. The values of H p (3)/A—normalised personal eye dose equivalent recorded in the group of radiochemists during the procedure of dispensing the doses of 68 Ga-DOTA-TATE for patients exceeded the value of 274 μ Sv/GBq. Conclusions. The estimated annual H p (3) values may exceed 20 mSv, which is particularly important due to the fact that procedures using the 68 Ga radioactivity are only a small part of the daily professional activity of the staff, resulting from the performance of other procedures that require the use of other radioisotopes.
22 February 2020 in Radiation and Environmental Biophysics
JMJoanna Maciocha-Stąporek
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For this, MTS-N thermoluminescent detectors (LiF: Mg, Ti) were exposed using a high-energy Clinac 2300 medical linear accelerator to doses of 100 mGy, 300 mGy, 500 mGy, 700 mGy and 1000 mGy. Irradiation with UV radiation allowed the determination of the optimal heating time of 3 h, while the optimal temperature was identified to be 70 °C. The results obtained demonstrated the usefulness of the PTTL method for emergency dose assessment. The efficiency of the PTTL method was determined as 19%. Finally it was found that the detector background after UV exposure should not be underestimated during routine dose measurements.
29 November 2018 in Radiation Protection Dosimetry
The production of 18F-FDG is a multi-stage process, which includes not only obtaining the marker and labelling the radiopharmaceutical but also carrying out the quality control of the obtained compound. The staff can be exposed to ionizing radiation at any stage of production. This article presents the results of hands exposure of staff members employed in a facility, where 18F-FDG is produced and injected into patients. High-sensitivity thermoluminescent detectors (MCP-N) were used for measurements. The measurements were conducted with regard to the occupational structure the employees and the performed procedures. The obtained results showed that the highest risk of radiation exposure for personnel was associated with the quality control of the radiopharmaceutical. The daily doses registered by MCP-N detectors on fingertips reached 4.5 mSv, which may result in exceeding the annual radiation limit of 500 mSv.
29 July 2020 in Radiation and Environmental Biophysics
The dose limit for the skin of the hand is typically converted to a surface of 1 cm2, which means that one needs to measure point doses in different places on the hand. However, the commonly used method of measuring doses on the hand, i.e., using a dosimetric ring including one or several thermoluminescent detectors worn at the base of a finger, is not adequate for manual procedures such as labeling or radiopharmaceutical injection. Consequently, the purpose of this study was to create and conduct a series of computer simulations that, by recreating the actual working conditions, would provide information on the values of ionizing radiation doses received by the most exposed parts of the hands of employees of radiopharmaceutical production facilities, as well as those of nurses during the injection of radiopharmaceuticals. The simulations were carried out using Monte Carlo radiation transport calculations. The Hp(0.07) personal dose equivalent values obtained for the fingertips of the index and middle fingers of nursing staff and chemists were within the range limited by the minimum and maximum Hp(0.07) values obtained as a result of dosimetric measurements carried out in diagnostic and production centers. Only in the case of the nurse’s fingertip, the simulated value of Hp(0.07 slightly exceeded the measured maximum Hp(0.07) value. The comparison of measured and simulated dose values showed that the largest differences in Hp(0.07) values occurred at the thumb tip, and for ring finger and middle finger of some of the nurses investigated.