Valentyn Soldatenko

Valentyn Soldatenko

Auto-generated profile, based on publicly available information

Valentyn Soldatenko

Central Ukrainian National Technical University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2026 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
PPPetro Plieshkov
Petro Plieshkov
VZVasyl Zinzura
Vasyl Zinzura
KPKateryna Petrova
Kateryna Petrova
VSValentyn Soldatenko
Valentyn Soldatenko
ANAndrii Nekrasov
Andrii Nekrasov
This study investigates processes of automatic control over parameters of the distribution network mode at a voltage of 6–10 kV with a sharply changing asymmetric load. The task addressed relates to the compromised efficiency of existing systems for automatic control over symmetry-compensating devices, which are based on multi-criteria optimization methods with unchanged weight coefficients. Such systems continue to give maximum priority to reducing the steady-state voltage deviation even if it meets regulatory requirements. This leads to incomplete utilization of regulating reserve of the symmetry-compensating device. The system of automatic control over the symmetry-compensating device has been improved by integrating a fuzzy controller into its structure. This controller changes the values of weight coefficients in the objective function depending on the current values of the network mode parameters. The computer simulation has confirmed the effectiveness of the designed system, which provided a reduction in the mathematical expectations of the reactive power factor M[tanφ] by 13.9% and the voltage unbalance factor M[k2U] by 8.5% compared to the baseline. The increase in the efficiency of the control system is explained by its ability to adaptively change the weight coefficients. Thus, if there is a margin for the steady-state voltage deviation, the fuzzy controller reduces the weight coefficient that meets this criterion, directing the regulating resource of the symmetrical-compensating device to increase the level of reactive power compensation and reduce the level of asymmetry. A feature of the designed control system is the use of the levels of approximation of the current values of the steady-state deviation and voltage asymmetry to their regulatory permissible limits as input variables in the fuzzy controller. The designed automatic control system could be used in distribution electrical networks with a voltage of 6–10 kV at a sharply changing asymmetrical load

27 December 2023 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
PPPetro Plieshkov
Petro Plieshkov
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University
VZVasyl Zinzura
Vasyl Zinzura
SPSerhii Plieshkov
Serhii Plieshkov
VSValentyn Soldatenko
Valentyn Soldatenko
Petro Plieshkov, Professor, Doctor in Technics (Doctor of Technic Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: plieshkov@gmail.com, ORCID ID: 0000-0003-2141-4811 Vasyl Zinzura, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: vasiliyzinzura@gmail.com, ORCID ID: 0000-0001-6357-064X Serhii Plieshkov, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: sergploff@gmail.com, ORCID ID: 0000-0002-3120-5397 Valentyn Soldatenko, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: kirovograd41@gmail.com, ORCID ID: 0000-0002-7781-9343 Abstract The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. Keywords solar power plant, computer modeling, distribution network Full Text: PDF References 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266 [in English]. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences, Vol. 434. DOI:10.1051/e3sconf/202343401015 [in English]. 3. Kansal, S., Kumar, V. & Tyagi B. (2016). Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems, Vol. 75, P. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002 [in English]. 4. Chen, M., Ma, S., Soltani, Z., Ayyanar, R., Vittal, V. & Khorsand M. (2023). Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal,. Vol. 17, No.3, P. 3436-3446. DOI: 10.1109/JSYST.2023.3256121 [in English]. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. (2023) Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies, vol.16 (16), 5907; DOI: 10.3390/en16165907 [in English]. 6. Plieshkov, P.H., Haras'ova, N.Yu. & Soldatenko, V.P. (2018). Optymal'ne keruvannia rezhymom roboty kombinovanoi elektroenerhetychnoi systemy z vidnovliuvanymy dzherelamy enerhii [Optimal Control of the Work of the Hybrid Electric Energy System With Renevable Sources of Energy]. Visnyk Natsional'noho tekhnichnoho universytetu «KhPI». Seriia: Problemy udoskonaliuvannia elektrychnykh mashyn i aparativ. Teoriia i praktyka - Bulletin of the National Technical University "KhPI". Collection of scientific works. Series: Problems of Improvement of Electric Machines and Apparatus, 32(1308), 64–70. DOI: 10.20998/2079-3944.2018.32 [in Ukrainian]. 7. Plieshkov, P., Soldatenko, V., Zinzura, V. & Plieshkov S. (2020). Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies, Vol. 103, No 1/2020, P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362 [in English]. 8. Power systems analysis software DIgSILENT PowerFactory. Retrieved from: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde, A. et al. (2021). Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy, No. 11, P. 331-342. DOI:10.32479/ijeep.11145 [in English]. 10. Perelmuter, V. (2020). Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 314 p. DOI: https://doi.org/10.1201/9780429324055 [in English]. Citations 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences. Vol. 434. DOI:10.1051/e3sconf/202343401015 3. Kansal S., Kumar V., Tyagi B. Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems. 2016. Vol. 75. Р. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002. 4. Chen M., Ma S., Soltani Z., Ayyanar R., Vittal V., Khorsand M. Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal. 2023. Vol. 17, No. 3. Р. 3436-3446. DOI: 10.1109/JSYST.2023.3256121. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies. 2023. Vol.16 (16). Р. 5907. DOI: 10.3390/en16165907 6. Плєшков П.Г., Гарасьова Н.Ю., Солдатенко В.П. Оптимальне керування режимом роботи комбінованої електроенергетичної системи з відновлюваними джерелами енергії. Вісник Національного технічного університету «ХПІ». Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика. 2018. №32 (1308). С. 64-70. 7. Plieshkov P., Soldatenko V., Zinzura V., Plieshkov S. Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies. 2020. Vol. 103, No 1/2020. P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362. 8. Power systems analysis software DIgSILENT PowerFactory. – Режим доступу: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde A., Owoicho O., Shomefun T., Olowoleni O., Ignatius O., Abdulkareem A. Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy. 2021. No. 11. Р. 331-342. DOI:10.32479/ijeep.11145 10. Perelmuter, V. Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 2020. 314 p. DOI: https://doi.org/10.1201/9780429324055 Copyright (c) 2023 Petro Plieshkov, Vasyl Zinzura, Serhii Plieshkov, Valentyn Soldatenko

29 May 2023 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
SOSergey Osadchy
Sergey Osadchy
LVLarisa Vikhrova
Larisa Vikhrova
MMMariya Miroshnichenko
Mariya Miroshnichenko
VSValentin Soldatenko
Valentin Soldatenko
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University

29 May 2023 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
NHNataliia Harasova
Nataliia Harasova
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University
AKAndrii Kotysh
Andrii Kotysh
VSValentyn Soldatenko
Valentyn Soldatenko
VZVasyl Zinzura
Vasyl Zinzura

1 December 2019 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University
VSValentyn Soldatenko
Valentyn Soldatenko
VZVasyl Zinzura
Vasyl Zinzura
SPSerhii Plieshkov
Serhii Plieshkov
NHNataliia Harasova
Nataliia Harasova
TVTetiana Velychko
Tetiana Velychko

28 May 2026 in Herald of Khmelnytskyi National University. Technical sciences
Verified
Journal Article
Open access
ПППетро Плєшков
Петро Плєшков
ВЗВасиль Зінзура
Василь Зінзура
КПКатерина Петрова
Катерина Петрова
ВСВалентин Солдатенко
Валентин Солдатенко
The work is devoted to solving the urgent problem of increasing the energy efficiency of artificial lighting systems in educational institutions. In modern schools and universities, lighting accounts for a significant share of total energy consumption, while ensuring a high-quality lighting environment is critically important for the health and performance of students. The aim of the work is to develop and study a centralized control method that effectively combines artificial and natural light, minimizing energy losses while complying with sanitary standards. The authors analyzed the shortcomings of traditional decentralized control systems based on local PID controllers. It was shown that such systems, due to the lack of coordination between light sources, are prone to overestimating the level of illumination to guarantee standards at the worst points. To solve this problem, a mathematical model of the light field in a classroom with combined lighting was developed. The control problem is formulated as a multi-criteria optimization problem. The proposed approach uses the method of approximation to a utopian point in the space of criteria to find a compromise between three conflicting criteria: total power consumption, light distribution uniformity and tracking error. Numerical simulation was carried out for a typical auditorium with a window under conditions of intense insolation. Comparative analysis showed that the proposed automatic control system reduces electricity consumption from 114.56 W (baseline PID model) to 103.58 W. Energy savings amounted to 9.58%. The system demonstrated higher control accuracy: the average absolute error decreased from 303.6 lux to 269.5 lux. In contrast to the baseline model, which maintained an excess minimum illumination of 474.1 lux, the optimized system reached a level of exactly 450.0 lux, operating at the limit of the permissible area. This proves that the algorithm intelligently adapts the light flux, dimming the lamps near the window and compensating for the lack of light only in the depths of the room. The implementation of the developed algorithms in building control systems allows achieving significant energy savings in educational buildings without upgrading power equipment, solely through software optimization of control modes.