Petro Plieshkov

Petro Plieshkov

Auto-generated profile, based on publicly available information

Petro Plieshkov

Central Ukrainian National Technical University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 January 2019 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University
PPPetro Pleshkov
Petro Pleshkov
SSSergiy Serebrennikov
Sergiy Serebrennikov
CUCentral Ukrainian National Technical Universit
Central Ukrainian National Technical Universit
KPKateryna Petrova
Kateryna Petrova
OSOleksandr Sirikov
Oleksandr Sirikov

27 December 2023 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
PPPetro Plieshkov
Petro Plieshkov
CUCentral Ukrainian National Technical University
Central Ukrainian National Technical University
VZVasyl Zinzura
Vasyl Zinzura
SPSerhii Plieshkov
Serhii Plieshkov
VSValentyn Soldatenko
Valentyn Soldatenko
Petro Plieshkov, Professor, Doctor in Technics (Doctor of Technic Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: plieshkov@gmail.com, ORCID ID: 0000-0003-2141-4811 Vasyl Zinzura, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: vasiliyzinzura@gmail.com, ORCID ID: 0000-0001-6357-064X Serhii Plieshkov, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: sergploff@gmail.com, ORCID ID: 0000-0002-3120-5397 Valentyn Soldatenko, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: kirovograd41@gmail.com, ORCID ID: 0000-0002-7781-9343 Abstract The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. Keywords solar power plant, computer modeling, distribution network Full Text: PDF References 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266 [in English]. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences, Vol. 434. DOI:10.1051/e3sconf/202343401015 [in English]. 3. Kansal, S., Kumar, V. & Tyagi B. (2016). Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems, Vol. 75, P. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002 [in English]. 4. Chen, M., Ma, S., Soltani, Z., Ayyanar, R., Vittal, V. & Khorsand M. (2023). Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal,. Vol. 17, No.3, P. 3436-3446. DOI: 10.1109/JSYST.2023.3256121 [in English]. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. (2023) Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies, vol.16 (16), 5907; DOI: 10.3390/en16165907 [in English]. 6. Plieshkov, P.H., Haras'ova, N.Yu. & Soldatenko, V.P. (2018). Optymal'ne keruvannia rezhymom roboty kombinovanoi elektroenerhetychnoi systemy z vidnovliuvanymy dzherelamy enerhii [Optimal Control of the Work of the Hybrid Electric Energy System With Renevable Sources of Energy]. Visnyk Natsional'noho tekhnichnoho universytetu «KhPI». Seriia: Problemy udoskonaliuvannia elektrychnykh mashyn i aparativ. Teoriia i praktyka - Bulletin of the National Technical University "KhPI". Collection of scientific works. Series: Problems of Improvement of Electric Machines and Apparatus, 32(1308), 64–70. DOI: 10.20998/2079-3944.2018.32 [in Ukrainian]. 7. Plieshkov, P., Soldatenko, V., Zinzura, V. & Plieshkov S. (2020). Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies, Vol. 103, No 1/2020, P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362 [in English]. 8. Power systems analysis software DIgSILENT PowerFactory. Retrieved from: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde, A. et al. (2021). Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy, No. 11, P. 331-342. DOI:10.32479/ijeep.11145 [in English]. 10. Perelmuter, V. (2020). Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 314 p. DOI: https://doi.org/10.1201/9780429324055 [in English]. Citations 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences. Vol. 434. DOI:10.1051/e3sconf/202343401015 3. Kansal S., Kumar V., Tyagi B. Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems. 2016. Vol. 75. Р. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002. 4. Chen M., Ma S., Soltani Z., Ayyanar R., Vittal V., Khorsand M. Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal. 2023. Vol. 17, No. 3. Р. 3436-3446. DOI: 10.1109/JSYST.2023.3256121. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies. 2023. Vol.16 (16). Р. 5907. DOI: 10.3390/en16165907 6. Плєшков П.Г., Гарасьова Н.Ю., Солдатенко В.П. Оптимальне керування режимом роботи комбінованої електроенергетичної системи з відновлюваними джерелами енергії. Вісник Національного технічного університету «ХПІ». Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика. 2018. №32 (1308). С. 64-70. 7. Plieshkov P., Soldatenko V., Zinzura V., Plieshkov S. Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies. 2020. Vol. 103, No 1/2020. P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362. 8. Power systems analysis software DIgSILENT PowerFactory. – Режим доступу: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde A., Owoicho O., Shomefun T., Olowoleni O., Ignatius O., Abdulkareem A. Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy. 2021. No. 11. Р. 331-342. DOI:10.32479/ijeep.11145 10. Perelmuter, V. Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 2020. 314 p. DOI: https://doi.org/10.1201/9780429324055 Copyright (c) 2023 Petro Plieshkov, Vasyl Zinzura, Serhii Plieshkov, Valentyn Soldatenko

1 June 2019 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
PPP.H. Plieshkov
P.H. Plieshkov
VZV.V. Zinzura
V.V. Zinzura
SPS.P. Plieshkov
S.P. Plieshkov
Automatic control of electrical distribution network mode with the voltage unbalance

30 April 2026 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
PPPetro Plieshkov
Petro Plieshkov
VZVasyl Zinzura
Vasyl Zinzura
KPKateryna Petrova
Kateryna Petrova
VSValentyn Soldatenko
Valentyn Soldatenko
ANAndrii Nekrasov
Andrii Nekrasov
This study investigates processes of automatic control over parameters of the distribution network mode at a voltage of 6–10 kV with a sharply changing asymmetric load. The task addressed relates to the compromised efficiency of existing systems for automatic control over symmetry-compensating devices, which are based on multi-criteria optimization methods with unchanged weight coefficients. Such systems continue to give maximum priority to reducing the steady-state voltage deviation even if it meets regulatory requirements. This leads to incomplete utilization of regulating reserve of the symmetry-compensating device. The system of automatic control over the symmetry-compensating device has been improved by integrating a fuzzy controller into its structure. This controller changes the values of weight coefficients in the objective function depending on the current values of the network mode parameters. The computer simulation has confirmed the effectiveness of the designed system, which provided a reduction in the mathematical expectations of the reactive power factor M[tanφ] by 13.9% and the voltage unbalance factor M[k2U] by 8.5% compared to the baseline. The increase in the efficiency of the control system is explained by its ability to adaptively change the weight coefficients. Thus, if there is a margin for the steady-state voltage deviation, the fuzzy controller reduces the weight coefficient that meets this criterion, directing the regulating resource of the symmetrical-compensating device to increase the level of reactive power compensation and reduce the level of asymmetry. A feature of the designed control system is the use of the levels of approximation of the current values of the steady-state deviation and voltage asymmetry to their regulatory permissible limits as input variables in the fuzzy controller. The designed automatic control system could be used in distribution electrical networks with a voltage of 6–10 kV at a sharply changing asymmetrical load

29 September 2025 in Central Ukrainian Scientific Bulletin. Technical Sciences
Verified
Journal Article
Closed access
PPPetro Plieshkov
Petro Plieshkov
VSValentyn Soldatenko
Valentyn Soldatenko
VZVasyl Zinzura
Vasyl Zinzura
SPSerhii Plieshkov
Serhii Plieshkov
Petro Plieshkov, Professor, Candidate of Technical Sciences, Head of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0003-2141-4811, e-mail: kafedra.etsem@gmail.com Valentyn Soldatenko, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-7781-9343, e-mail: kirovograd41@gmail.com Vasyl Zinzura, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0001-6357-064X, e-mail: vasiliyzinzura@gmail.com Oleksandr Sirikov, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-7058-2697, e-mail: asirikov@i.ua Serhii Plieshkov, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Automation of Production Processes, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-3120-5397, e-mail: sergploff@gmail.com. The purpose of this article is to develop an effective approach to automated control of the level of active power generation in systems based on renewable energy sources in order to ensure maximum electricity generation while complying with the regulatory permissible voltage deviation limits at the points of connection of electricity consumers to the distribution grid. The article analyzes the problems that arise when generating electricity from renewable sources in the conditions of distribution grids - in particular, exceeding the permissible voltage level at the points of connection and reducing the economic efficiency of generation when using typical automatic control systems. It is proposed to improve the system for automatic control of the level of active power generation by installations with renewable energy sources by formalizing the control process as a multi-criteria optimization problem. The main criteria are profit from the sale of electricity and economic losses from voltage quality disturbances. The problem is solved by the method of approximation to the utopian point using the Chebyshev metric and numerical methods of discrete optimization. For this purpose, a step-by-step algorithm was developed, which involves discretization of the area of permissible generation values, calculation of the Pareto-optimal set, determination of the utopian point and minimization of the distance to it. In order to assess the effectiveness of the proposed approach, a computer model of the automatic control system was built, which is based on the specified algorithm. The model was tested in a simulation environment, where it was compared with a traditional control system that provides a strict limitation of the voltage deviation. The simulation results showed that the proposed approach provides an increase in the volume of electricity supply to the network by 8.1% compared to the base model. At the same time, the level of the steady-state voltage deviation at the connection point meets the regulatory requirements for the quality of electricity (integral probability - 95%). Thus, the improved automatic control system allows achieving both technical and economic optimality of the functioning of renewable energy sources in the power system