Thomas Dautremer

Thomas Dautremer

Auto-generated profile, based on publicly available information

Thomas Dautremer

Université Paris-Saclay CEA F-91120 Palaiseau List France

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
NDN. Dufour
N. Dufour
JDJ. Dumazert
J. Dumazert
EBE. Barat
E. Barat
GBG.H.V. Bertrand
G.H.V. Bertrand
FCF. Carrel
F. Carrel
ASA. Sari
A. Sari

24 January 2025 in Monthly Notices of the Royal Astronomical Society
Verified
Journal Article
Open access
CMChristophe Morisset
Christophe Morisset
SCStéphane Charlot
Stéphane Charlot
SSSebastian Sanchez
Sebastian Sanchez
CECarlos Espinosa-Ponce
Carlos Espinosa-Ponce
EBEric Barat
Eric Barat
TDThomas Dautremer
Thomas Dautremer
We introduce a novel approach to modelling the nebular emission from star-forming galaxies by combining the contributions from many H ii regions incorporating loose trends in physical properties, random dust attenuation, a predefined H$\alpha$ luminosity function, and a diffuse ionized-gas component. Using a machine-learning-based regression artificial neural network trained on a grid of models generated by the photoionization code cloudy, we efficiently predict emission-line properties of individual H ii regions over a wide range of physical conditions. We generate 250 000 synthetic star-forming galaxies composed of up to 3000 H ii regions and explore how variations in parameters affect their integrated emission-line properties. Our results highlight systematic biases in oxygen-abundance estimates derived using traditional methods, emphasizing the importance of accounting for the composite nature of star-forming galaxies when interpreting integrated nebular emission. Future work will leverage this approach to explore in detail its impact on parameter estimates of star-forming galaxies.

29 June 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
ICI Chabert
I Chabert
EBE Barat
E Barat
TDT Dautremer
T Dautremer
TMT Montagu
T Montagu
MAM Agelou
M Agelou
DLD Lazaro
D Lazaro
This work aims at developing a generic virtual source model (VSM) preserving all existing correlations between variables stored in a Monte Carlo pre-computed phase space (PS) file, for dose calculation and high-resolution portal image prediction. The reference PS file was calculated using the PENELOPE code, after the flattening filter (FF) of an Elekta Synergy 6 MV photon beam. Each particle was represented in a mobile coordinate system by its radial position (r s ) in the PS plane, its energy (E), and its polar and azimuthal angles (phiv d and θ d ), describing the particle deviation compared to its initial direction after bremsstrahlung, and the deviation orientation. Three sub-sources were created by sorting out particles according to their last interaction location (target, primary collimator or FF). For each sub-source, 4D correlated-histograms were built by storing E, r s , phiv d and θ d values. Five different adaptive binning schemes were studied to construct 4D histograms of the VSMs, to ensure histogram efficient handling as well as an accurate reproduction of E, r s , phiv d and θ d distribution details. The five resulting VSMs were then implemented in PENELOPE. Their accuracy was first assessed in the PS plane, by comparing E, r s , phiv d and θ d distributions with those obtained from the reference PS file. Second, dose distributions computed in water, using the VSMs and the reference PS file located below the FF, and also after collimation in both water and heterogeneous phantom, were compared using a 1.5%–0 mm and a 2%–0 mm global gamma index, respectively. Finally, portal images were calculated without and with phantoms in the beam. The model was then evaluated using a 1%–0 mm global gamma index. Performance of a mono-source VSM was also investigated and led, as with the multi-source model, to excellent results when combined with an adaptive binning scheme.

23 March 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HAHanan Arahmane
Hanan Arahmane
JDJonathan Dumazert
Jonathan Dumazert
EBEric Barat
Eric Barat
TDThomas Dautremer
Thomas Dautremer
NDNicolas Dufour
Nicolas Dufour
FLFrederic Laine
Frederic Laine
In this article, we aim at measuring a low-activity uranium contamination deposited on concrete surfaces of a nuclear facility and presenting varying enrichment levels. Considering this application field, CEA LIST, has developed an original approach, combining gamma-ray spectrometry based on high-purity germanium (HPGe) measurements and specific Bayesian algorithms. This methodology gives access to an indirect surface activity estimation, assuming that the ratio between the number of alpha particles to be quantified and the number of detected gamma rays is known. The Bayesian approach characteristic property is able to inject a representation of the physical context in the form of a probabilistic a priori. It enables to improve the tradeoff between the true detection rate (TDR) and the false alarm rate (FAR) at low count rates and takes benefit of a richer time-energy information structure than the algorithms used in the conventional detection procedures. The performance evaluation and characterization of Bayesian statistical tests are performed using classical receiver-operating characteristic (ROC) curves by comparison to frequentist hypothesis tests. Results indicate that the Bayesian approach has a superior detection performance for low-activity uranium contamination compared to the frequentist approach. The estimated gain is contained between 30% and 50%, considering a variable or stable radiological background. The Bayesian approach offers the best tradeoff between the TDR, FAR, and the response time and is compatible with the user's requirements.

1 June 2013
Verified
Conference Paper
Open access
EBEric Barat
Eric Barat
SNStephane Normand
Stephane Normand
TDThomas Dautremer
Thomas Dautremer
JLJeremie Lefevre
Jeremie Lefevre
CHCedric Herman
Cedric Herman
Gabriele GrassiGabriele Grassi
Gabriele Grassi
This work deals with the last measurement campaign done at the AREVA NC La Hague reprocessing plant with the new industrial ADONIS system called ADONIS LYNX. In this paper we briefly explain the ADONIS bimodal Kalman smoother. Next, we present the experimental set-up as well as the industrial approach for the ADONIS system. Results from measurement campaign are then discussed. Some ways of improvement are also explained.

2 December 2021 in arXiv
Verified
Preprint
Open access
PDF file
FGFedor Goncharov
Fedor Goncharov
ÉBÉric Barat
Éric Barat
TDThomas Dautremer
Thomas Dautremer
We continue studies of the uncertainty quantification problem in emission tomographies such as PET or SPECT when additional multimodal data (e.g., anatomical MRI images) are available. To solve the aforementioned problem we adapt the recently proposed nonparametric posterior learning technique to the context of Poisson-type data in emission tomography. Using this approach we derive sampling algorithms which are trivially parallelizable, scalable and very easy to implement. In addition, we prove conditional consistency and tightness for the distribution of produced samples in the small noise limit (i.e., when the acquisition time tends to infinity) and derive new geometrical and necessary condition on how MRI images must be used. This condition arises naturally in the context of identifiability problem for misspecified generalized Poisson models. We also contrast our approach with Bayesian Markov Chain Monte Carlo sampling based on one data augmentation scheme which is very popular in the context of Expectation-Maximization algorithms for PET or SPECT. We show theoretically and also numerically that such data augmentation significantly increases mixing times for the Markov chain. In view of this, our algorithms seem to give a reasonable trade-off between design complexity, scalability, numerical load and assessment for the uncertainty.