1 January 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
23 March 2021 in IEEE Transactions on Instrumentation and Measurement
In this article, we aim at measuring a low-activity uranium contamination deposited on concrete surfaces of a nuclear facility and presenting varying enrichment levels. Considering this application field, CEA LIST, has developed an original approach, combining gamma-ray spectrometry based on high-purity germanium (HPGe) measurements and specific Bayesian algorithms. This methodology gives access to an indirect surface activity estimation, assuming that the ratio between the number of alpha particles to be quantified and the number of detected gamma rays is known. The Bayesian approach characteristic property is able to inject a representation of the physical context in the form of a probabilistic a priori. It enables to improve the tradeoff between the true detection rate (TDR) and the false alarm rate (FAR) at low count rates and takes benefit of a richer time-energy information structure than the algorithms used in the conventional detection procedures. The performance evaluation and characterization of Bayesian statistical tests are performed using classical receiver-operating characteristic (ROC) curves by comparison to frequentist hypothesis tests. Results indicate that the Bayesian approach has a superior detection performance for low-activity uranium contamination compared to the frequentist approach. The estimated gain is contained between 30% and 50%, considering a variable or stable radiological background. The Bayesian approach offers the best tradeoff between the TDR, FAR, and the response time and is compatible with the user's requirements.
20 January 2020 in EPJ Web of Conferences
In the frame of a partnership between CEA and VINCI, various measurement techniques are applied to soil analysis and tested in different laboratories located at CEA Saclay (France). This paper deals with two nuclear measurement techniques assessed in this project. More specifically, this paper presents the feasibility study carried out for two non-destructive active methods: photon activation and neutron activation. First, some atomic nuclides are activated either by photons or neutrons. Secondly, gamma-rays of specific energies are emitted by activated nuclides and gamma-ray spectrometry enables to identify these activated nuclides. Calibration of the full measurement system with reference samples would enable to quantify the mass of activated nuclides. Irradiations performed for photon activation measurements were conducted using a linear electron accelerator (linac) as the latter enables to generate high-energy photons by Bremsstrahlung thanks to its conversion target. Furthermore, irradiations performed for neutron activation measurements were also conducted with a linac. Indeed, photons may be converted to neutrons by photonuclear reactions using a secondary target. In the frame of this project, experiments were carried out at the SAPHIR platform (CEA Saclay) with a Linatron-M9 VARIAN linac. The electron energy was either 6 or 9 MeV. For neutron activation measurements, a secondary target made of heavy water has been used as neutron source and a polyethylene cell enabled to thermalize neutrons and increase the number of reactions of interest. In this paper, we present the different experimental setups and the measurement protocols established for this feasibility study. We show experimental results obtained with raw material samples coming from three construction sites.