Ahmet Murad Hondur

Ahmet Murad Hondur

Auto-generated profile, based on publicly available information

Ahmet Murad Hondur

Columbia University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Cornea
Verified
Journal Article
Closed access
KBKamil Bilgihan
Kamil Bilgihan
AHAhmet Hondur
Ahmet Hondur
SSSabahattin Sul
Sabahattin Sul
SOSertac Ozturk
Sertac Ozturk
Purpose: To report eyes with keratoconus that progressed during pregnancy. Methods: Seven eyes of 4 patients with progression of keratoconus during pregnancy were included in this study. The mean age of patients and the mean follow-up duration were 29.3 years and 39 months, respectively. Progressive keratoconus was documented with changes in refraction, corneal topography, and rigid gas-permeable lens fitting pattern. Patients with accompanying systemic and ocular diseases associated with keratoconus, uncontrolled atopic disease, and eye rubbing were excluded. Results: Mean increase in spherical equivalent refraction and simulated keratometry values were 1.4 ± 1.1 and 1.1 ± 0.8 diopters, respectively. In eyes wearing rigid gas-permeable lenses, increase in corneal apical touch and decrease in the base curve radius of the best-fitting contact lens were observed. Conclusions: Hormonal changes during pregnancy may affect corneal biomechanics negatively, and pregnancy may be a previously unrecognized risk factor for progression of keratoconus. To our knowledge, this is the first study showing pregnancy-induced keratoconus progression in patients with no accompanying disease.

1 March 2014 in Acta Biomaterialia
Verified
Journal Article
Open access
GUG. Uzunalli
G. Uzunalli
ZSZ. Soran
Z. Soran
TET.S. Erkal
T.S. Erkal
YDY.S. Dagdas
Y.S. Dagdas
EDE. Dinc
E. Dinc
ATAyse Begum Tekinay
Ayse Begum Tekinay
Defects in the corneal stroma caused by trauma or diseases such as macular corneal dystrophy and keratoconus can be detrimental for vision. Development of therapeutic methods to enhance corneal regeneration is essential for treatment of these defects. This paper describes a bioactive peptide nanofiber scaffold system for corneal tissue regeneration. These nanofibers are formed by self-assembling peptide amphiphile molecules containing laminin and fibronectin inspired sequences. Human corneal keratocyte cells cultured on laminin-mimetic peptide nanofibers retained their characteristic morphology, and their proliferation was enhanced compared with cells cultured on fibronectin-mimetic nanofibers. When these nanofibers were used for damaged rabbit corneas, laminin-mimetic peptide nanofibers increased keratocyte migration and supported stroma regeneration. These results suggest that laminin-mimetic peptide nanofibers provide a promising injectable, synthetic scaffold system for cornea stroma regeneration.

29 August 2020 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
YAYavuz Kemal Aribas
Yavuz Kemal Aribas
AHAhmet M. Hondur
Ahmet M. Hondur
TTTongalp H. Tezel
Tongalp H. Tezel

2 January 2015 in Current Eye Research
Verified
Journal Article
Closed access
PDF file
AHAhmet M. Hondur
Ahmet M. Hondur
HAHanife Tuba Akcam
Hanife Tuba Akcam
EKEmine Esra Karaca
Emine Esra Karaca
HEHulya Yazici Eroglu
Hulya Yazici Eroglu
BABahri Aydin
Bahri Aydin
Purpose: To evaluate the effect of autologous serum on the rate of epithelial healing and clinical results after laser epithelial keratectomy (LASEK) for correction of myopia. Materials and Methods: Thirty eyes of 15 patients received autologous serum drops (Study Group) while 30 eyes of 15 patients received conventional artificial tears (Control Group) after LASEK. LASEK was performed with 25-second application of 18% alcohol. Laser ablation was performed with the ESIRIS excimer laser (SCHWIND, Kleinostheim, Germany). Patients were seen daily until epithelial closure, and at 1, 3, 6, and 12 months. Time to epithelial healing was the main outcome measure. Uncorrected visual acuity (UCVA), manifest refraction, and haze were recorded. Results: Preoperative myopic spherical equivalent refraction was −2.98 ± 1.13 diopters (D) in the study group and −2.65 ± 1.01 D in the control group (p = 0.264). The mean time to epithelial healing was about 1 day shorter in the eyes receiving autologous serum than the eyes receiving conventional treatment (2.78 ± 0.40 days versus 3.73 ± 0.58 days, respectively) (p = 0.001). All eyes achieved 20/25 or better UCVA at 6 months. Over 90% of eyes were within ±0.50 D of emmetropia at 12 months in both groups. No significant difference was noted in the incidence of haze. Conclusions: Autologous serum eye drops seem to accelerate epithelial healing after LASEK, which may shorten the duration of early postoperative discomfort by about 1 day.

13 September 2024 in Ophthalmology
Verified
Journal Article
Closed access
AHAhmet M. Hondur
Ahmet M. Hondur
GMGolnaz Moazami
Golnaz Moazami
GHGozde Hondur
Gozde Hondur
TTTongalp H. Tezel
Tongalp H. Tezel

23 June 2020 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
KBKemal Bayrakceken
Kemal Bayrakceken
AHAhmet Murad Hondur
Ahmet Murad Hondur
TATuba Atalay
Tuba Atalay
YAYavuz Kemal Aribas
Yavuz Kemal Aribas
To compare the clinical use, image quality and viewing angle of a commonly used contact wide angle viewing (WAV) system (Advanced Visual Instruments Panoramic Imaging Systems, NY, USA) with a commonly used non-contact WAV system (Leica RUV800, Leica Microsystems, Switzerland). Images of 42 consecutively operated eyes were obtained with both systems at the same surgical stages, and were compared for image quality using the Imatest Master 4.5.13 (Imatest LLC, Boulder, USA) software. The viewing angles of the images were calculated using the optic disc sizes measured from the OCT and infrared fundus images. The 68 degree AVI lens was compared with the 90-diopter (D) Leica RUV800 lens, while the 130 degree AVI lens was compared with the 132-D Leica RUV800 lens. The surgical assistants were asked to grade the difficulty of holding the lens in place from 1 to 10, 1 being easiest and 10 being the most difficult. The contact system provided wider viewing angles with higher quality compared to the non-contact system both under fluid and air media. The difference was clinically significant in eyes with impaired corneal clarity, very high myopia, or small pupil. The difficulty of holding the lens in place ranged from 4 to 7, and decreased gradually with practice. Both WAV systems provided high image quality and adequate viewing angles in most cases. However, the contact system appeared to be provide a superior image quality and/or a wider viewing angle in more challenging situations. The difficulty of holding the contact lens in place was found to be moderate.