Ulughbek Akhmadjonov

Ulughbek Akhmadjonov

Auto-generated profile, based on publicly available information

Ulughbek Akhmadjonov

Tashkent Institute of Chemical Technology

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2025 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
KUKhilola Usmanova
Khilola Usmanova
ZSZulayho Smanova
Zulayho Smanova
AEAzoda Ermatova
Azoda Ermatova
KBKhikmat Bobojonov
Khikmat Bobojonov
UAUlugbek Akhmadjonov
Ulugbek Akhmadjonov
DNDilmurod Nasirdinov
Dilmurod Nasirdinov

7 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
FTFeruzakhon Tojiboyeva
Feruzakhon Tojiboyeva
ZSZulayho Smanova
Zulayho Smanova
KUKhilola Usmanova
Khilola Usmanova
MMMuattar Mamedova
Muattar Mamedova
ATAyjamal Turambetova
Ayjamal Turambetova
Enrico BenassiEnrico Benassi
Enrico Benassi
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions. Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085. Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.

18 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
FTFeruzakhon Tojiboyeva
Feruzakhon Tojiboyeva
ZSZulayho Smanova
Zulayho Smanova
KUKhilola Usmanova
Khilola Usmanova
MMMuattar Mamedova
Muattar Mamedova
ATAyjamal Turambetova
Ayjamal Turambetova
Enrico BenassiEnrico Benassi
Enrico Benassi
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions.Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085.Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.